¿ªÔÆÌåÓý

ctrl + shift + ? for shortcuts
© 2025 Groups.io
Date
Re: Accuracy of calculated values - Nano VNA and Saver
Rudi, thank you very much for your kind comments :-) -- Rune / 5Q5R
By Rune Broberg · #4038 ·
Re: Accuracy of calculated values - Nano VNA and Saver
Hi David, your suggestion of interfacing with the HP 8753 is certainly interesting! I am going to have the code reworked at some point to accept more VNA types, so an 8753 option isn't completely
By Rune Broberg · #4037 ·
Re: info update
NO YES NO Same as DMR-CLEAR_MEMORY_DFU.dfu NO NO
By Larry Rothman · #4036 ·
Re: info update
Really good! Congratulations for your job. I read it well tomorrow morning. Thanks
By @in3elx · #4035 ·
Re: Method of equivalent circuit used on HP 4284A LCR meter
Hi David, thanks for the list! That's a lot of ways to display the same couple of numbers ;-) But I'm sure all very useful. I'll keep it around for future reference :-) -- Rune
By Rune Broberg · #4034 ·
Re: info update
I collected some of this information near the top of Firmware Versions http://ormpoa.altervista.org/firmware.htm .. which is at the bottom of Wiki Main Menu page /g/nanovna-users/wiki
By Oristo · #4033 ·
Re: info update
Thanks. It's all very perfect. I already had these files. But I asked other questions. I repeat: Does DfuSe_Demo_V3.0.6_Setup.exe have 30-day work limitations? Yes or no? DMR-CLEAR_MEMORY_DFU.dfu is
By @in3elx · #4032 ·
Re: Supply voltage requirement?
Mike - Don't use anything else! The NanoVNA was designed to use only a 5V supply, via the USB port. The internal charge IC is both a 3.7V LiIon charger and 5V inverter combo - there are lots of
By Larry Rothman · #4031 ·
Supply voltage requirement?
Is there an on-board voltage regulator that converts 5.0V from the USB to whatever is used internally? If so, what external voltage range could be used in lieu of 5.0V from USB (but through the USB
By mike miniver · #4030 ·
Re: info update
Use Chrome Browser with its built-in language translation capability. Then -? Go to the NanoVNA group webpage at:??? /g/nanovna-users/topics Look at WIKI and FILES sections at
By Larry Rothman · #4029 ·
Re: info update
@in3elx wrote: Is there a document that explains the update procedure for those who have never done this? The answer is on page 19 of 29 of the document named 'NanoVNA User
By NanoVNA · #4028 ·
Determining SOLT kit errors via basis pursuit
FYI I have started a thread on EEVblog under this subject line. This is serious math wonk territory, so I don't want to clutter an already very busy list with it. Have Fun! Reg
By Reginald Beardsley · #4027 ·
Re: Bad nanovna?
Make sure you're measure correct channel. You should see CH1 (not CH0) near blue LOGMAG text with value at the top of screen.
By QRP RX · #4026 ·
Re: info update
Could you be kinder? I just joined this system (which I don't know). I don't speak English very well and this is already difficult for me. If someone can put some links with useful information ...
By @in3elx · #4025 ·
Re: Return Loss
RL = -20 * log10( abs(gamma) ) where gamma is a complex reflection coefficient In order to get negative RL, we needs abs(gamma) > 1, it means that reflected wave is higher than incident wave.
By QRP RX · #4024 ·
Re: Bad nanovna?
Thanks. I did all that, still no S21. I think it's blown up. There is also an incompatibility between the firmware files I found and the SGMicro bootloader pgm. It was listed as "new out of box" and
By Ken Bozarth · #4023 ·
Re: Bad nanovna?
I just went through a calibration and save and it seems to be working correctly this morning.? Time will tell. I almost ordered another unit.? Apparently the prices have dropped significantly. Bob
By Bob Albert <bob91343@...> · #4022 ·
Re: Bad nanovna?
Bob, If you are using the original firmware that came on your nanoVNA then the symptoms haven't been reported by other members and you may have a hardware problem. If you have upgraded your firmware
By hwalker · #4021 ·
Re: Is there an Android app for the NanoVNA - WebUSB
AFAIK, only the dev tree exists - there is no APK app that I can find. It would be nice if cho45 could convert his webpage to a standalone html file that anyone could run locally. NanoVNA-Web-Client
By Larry Rothman · #4020 ·
Re: Bad nanovna?
Ken, The 2-trace, unshielded ports, black unit is usually delivered uncalibrated and is not useable out of the box. The following usually gets it going: First select "RESET" under the "CAL" menu and
By hwalker · #4019 ·