Re: NanoVNA H / H4 / V2 / V2Plus / V2Plus4 firmware v1.0.69 #firmware
Stop sending the e-mail to me. I have even left the Group because I could not stop the mails CW4EVER
By Knud Jorgen Olsen-Jensen <vk2kjj@...> · #24005 ·
Re: Download NanaoVNA Labview
From the NI MAX web site: "NI MAX is only supported on Windows and MacOS, not Linux, and cannot be downloaded by itself. It is included with all NI drivers (NI-VISA, NI-DAQmx etc.) and NI System
By Donald S Brant Jr · #24004 ·
Re: NanoVNA H / H4 / V2 / V2Plus / V2Plus4 firmware v1.0.69 #firmware
Thank you for your reply DiSlord. I looked at both PCBs, 10R resistor for 3.3V I put in position R2 on "LCD" PCB, MOSI signals, MISO, SCLK are available on H1 connector on "LCD" PCB. The problem will
By Anton · #24003 ·
Re: Measuring Unknown #matching #transformer
Don¡¯t send me your emails CW4EVER
By Knud Jorgen Olsen-Jensen <vk2kjj@...> · #24002 ·
Re: Measuring Unknown #matching #transformer
Don¡¯t send me your emails CW4EVER
By Knud Jorgen Olsen-Jensen <vk2kjj@...> · #24001 ·
Re: Measuring S11 at input of RF power amplifier - could I calibrate "through" an attenuator?
The attenuators affect more than S11 SNR when used in this fashion They are not exactly 50 ohms input/output impedance. Also the calibration errors will probably be greater as the DUT impedance is
By Roger Need · #24000 ·
Re: download the calibration from the NanoVNA
Don¡¯t send me your emails CW4EVER
By Knud Jorgen Olsen-Jensen <vk2kjj@...> · #23999 ·
Re: download the calibration from the NanoVNA
Need use any console software (like terminal, putty RealTerm) You receive list of error tetm (used by nanoVna as calibration data) 'data 2' ED - error term directivity 'data 3' ES - error term source
By DiSlord · #23998 ·
Re: Measuring Unknown #matching #transformer
Hi, Luciano... I more or less (in my head) wrote off the "extra" resistance needed to make the NanoVNA see a flat match as being to a combination of lead resistance/reactance and operator error. I
By Charles KC6UFM <kc6ufm@...> · #23997 ·
Re: Measuring Unknown #matching #transformer
Hi Charles, I get "suspicious" when I see small differences like this i.e. 50 ohm as in this case. Assuming the black box is lossless, you should measure either 2450 or 2500 ohm if you load the other
By Luciano Luciano · #23996 ·
Re: download the calibration from the NanoVNA
I do not understand what you mean. Do you mean the nanovna-saver.exe window (mostly black with some status lines on it: I am not able to do a command from there)? Or is there some console within the
By Victor Reijs · #23995 ·
Re: Download NanaoVNA Labview
I worked for PWA for decades and was the only engineer that used LabVIEW, now all the engineers do. It is very easy to learn (very friendly for EEs) and yes it is expensive. So I am glad to see that
By Syd <nhuq1@...> · #23994 ·
Re: Measuring a 1/4 wave balanced line #cables
Great! Thanks. Any google search I attempted lead me to the RSGB website, which was a dead end for me. I did realize the forums were right here on groups.io, duh.
By Lou W7HV · #23993 ·
Measuring Unknown #matching #transformer
Hello, All... I recently had a need to measure an unknown matching transformer. As it was in a sealed enclosure with noth but the wire terminal and coax connector exposed, and I didn't want to damage
By Charles KC6UFM <kc6ufm@...> · #23992 ·
Re: Measuring a 1/4 wave balanced line #cables
[image: image.png] This should get you started. Dave - WLEV [email protected]> wrote: -- *Dave - W?LEV* *Just Let Darwin Work*
By W0LEV · #23991 ·
Re: Measuring S11 at input of RF power amplifier - could I calibrate "through" an attenuator?
What's the ripple in the measurement from? A reduced SNR would give a random error, not a periodic one, but maybe it's a manifestation of a phase bias that is contributing more or less depending on
By Jim Lux · #23990 ·
Re: Measuring S11 at input of RF power amplifier - could I calibrate "through" an attenuator?
on real amplifiers, with non zero S12, the load impedance does show up at the input - imagine an amplifier with S12 of -10 dB and a S11 of -100dB.? A total reflection at the output of the amp will
By Jim Lux · #23989 ·
Re: Measure Inductance?
This is what I get using an inductor (7 turns of RG58A through a toroid) and the component is connected to CH0 and calibrated: [image: afbeelding.png] You see the S11 |Z| graph is a straight line
By Victor Reijs · #23988 ·
Re: 340 MHz Dipole - Calibration at Transmitter and Antenna Ends of Transmission Line
Dave - Thanks once again for all the information. I'll test the modification using the 1/8 wavelength frequency in SimSmith and see how it compares. That change also allows the method posted by John
By Kent AA6P · #23987 ·
Re: Measuring a 1/4 wave balanced line #cables
Did a quick search for RSGB sites as described but didn't have any luck. Could you provide a link or more info to help find them? TNX
By Lou W7HV · #23986 ·