Wich one the get ? nanoVNA F or H4
Hello group, I would like to get a nano VNA ( already use great VNA at work ) to play with, but i am confusing about wich one to get? I would like the 4.3 or 4.0 inch display, but it's look like the F
By Guillaume Larouche · #11750 ·
Re: Checking 1:49 UnUn with nanovna #applications
WB2UAQ, Measuring antennas requires knowing what the ground is like. as it does change the result as well as orientation and height above it. I know the region and it does change depending on where
By aparent1/kb1gmx <kb1gmx@...> · #11749 ·
Re: Checking 1:49 UnUn with nanovna #applications
That might work if it were a dipole. for a end fed wire? The problem then is what represents the ground plane? An Endfed half wave (or any random wire) is like any antenna (dipoles for instance)
By aparent1/kb1gmx <kb1gmx@...> · #11748 ·
Re: Checking 1:49 UnUn with nanovna #applications
Allison, My previous comment to WB2UAQ was not about testing the 49:1 UN-UN wuth S21. It was about measuring the high feedpoint impedance of his 67 ft wire at 7 MHz. For high impedances like this
By Roger Need · #11747 ·
Re: Checking 1:49 UnUn with nanovna #applications
Larry I just watched your video and it does a good job of explaining the three methods. If you are interested in doing a follow-on it would be interesting to see the following: 1. Comparison between
By Roger Need · #11746 ·
Re: Checking 1:49 UnUn with nanovna #applications
Larry, Impedance measurement is more indirect then measuring the transformer directly. Both get you to the same point but the big thing is you have to understand what your measuring and what that
By aparent1/kb1gmx <kb1gmx@...> · #11745 ·
Re: Checking 1:49 UnUn with nanovna #applications
Roger, S21 to get it right really requires a known transformer or often easier two of the same back to back. That keep measurement in the 50 ohm domain and also allows for reasonable accuracy for loss
By aparent1/kb1gmx <kb1gmx@...> · #11744 ·
Extended Version of my NanoVNATutorial
Hi Rune, I want to tell you that I have added two parts to my NanoVNA tutorial: a) Part 2: the NanoVNA-H up to 1500 (1300) MHz with examples b) Part 3: the NanoVNA als TDR (= Time Domain
By Gunthard Kraus <mail@...> · #11743 ·
Re: Checking 1:49 UnUn with nanovna #applications
I recently made a video showing how to measure impedance 3 ways with a VNA including the s11, series sw1, and the shunt s21 methods. See https://www.youtube.com/watch?v=1UbEz73FGCU if interested.
By Larry Benko · #11742 ·
Re: NanoVNA-H4 What are the exact steps to a
Yes, the current brightness interface is very primitive. I need to provide a more friendly operation. Thank you for your suggestions.
By Hugen · #11741 ·
Re: NanoVNA-H4 What are the exact steps to a
The NanoVNA originally designed by edy555 allows the use of DAC to adjust VCTCXO, but when I made NanoVNA-H, I thought that adjusting VCTCXO was too much trouble for most users, so I used TCXO. For
By Hugen · #11740 ·
Re: NanoVNA-H4 What are the exact steps to a
On Sat, Mar 14, 2020 at 09:38 PM, <hugen@...> wrote: The NanoVNA-H4 uses DAC output dimming, so the brightness can be adjusted using DAC commands. Dac_value = 800 is the minimum brightness,
By hwalker · #11739 ·
Re: NanoVNA-H4 What are the exact steps to a
Thank you for the command information, Hugen. I have a minor H4 firmware enhancement request: is it possible to use the jog switch to change also brightness when in the brightness config GUI menu? I'm
By Larry Rothman · #11738 ·
Re: NanoVNA-H4 What are the exact steps to a
hwalker11 is right. The NanoVNA-H4 uses DAC output dimming, so the brightness can be adjusted using DAC commands. Dac_value = 800 is the minimum brightness, dac_value = 3300 is the maximum brightness,
By Hugen · #11737 ·
Re: NanoVNA-H4 What are the exact steps to a
On Sat, Mar 14, 2020 at 07:10 PM, Larry Rothman wrote: Maybe Hugen can let everyone know if there is a Console command to adjust the brightness on the H4?
By hwalker · #11736 ·
Re: Checking 1:49 UnUn with nanovna #applications
Kurt, Thanks for your comments. Yes I am familiar with the using Rp instead of Rs in NanoVNA saver. I agree that the CH0 and CH1 impedance needs to be close to 50 ohms for accurate results using the
By Roger Need · #11735 ·
Re: NanoVNA-H4 What are the exact steps to a
Maybe Hugen can let everyone know if there is a Console command to adjust the brightness on the H4? I've been attempting to keep Cho45's Original userguide up to date and have added quite a bit of
By Larry Rothman · #11734 ·
Re: NanoVNA-H4 What are the exact steps to adjus
Thank you, found that out later after I did the jumper update. I'm just scared to mess with the display setting anymore I don't want to end up stuck with a dark screen. It may be as bright as it gets
By Robert Klaus W7XLR · #11733 ·
Re: NanoVNA-H4 What are the exact steps to adjus
Robert, You no longer have to open the case to jumper the booth pins.? To put the unit into dfu mode, turn it off, press in and hold the jog switch and then turn on the unit and release the switch.?
By Larry Rothman · #11732 ·
Re: Checking 1:49 UnUn with nanovna #applications
Hi Roger Using the S21 methods requires that both the source (CH0) and load (CH1) impedance are pure 50 ohm, so you get also errors this way. Have you tried to read the Rp instead of Rs in
By Kurt Poulsen · #11731 ·