Keyboard Shortcuts
ctrl + shift + ? :
Show all keyboard shortcuts
ctrl + g :
Navigate to a group
ctrl + shift + f :
Find
ctrl + / :
Quick actions
esc to dismiss
Likes
- Nanovna-Users
- Messages
Search
Re: DiSlord build 1.2.19, saved cal files give error when reading
maybe you saved files without doing a full calibration (SOLT) so there are values missing?
toggle quoted message
Show quoted text
dg9bfc sigi ps as i have noted .. 1.3.15 is newest Am 05.03.2023 um 02:27 schrieb TheSpud via groups.io: Because of the problems with 1.2.14 missing the read from SD menu, I downloaded 1.2.19 and attempted to save my cal files again. They saved without errors, but when I try to read them I get format error. |
Re: H4 display defect
try resetting connectors maybe?? there could be just a bad contact
toggle quoted message
Show quoted text
try both .. the connector between the boards .. and also the flat band cable (loosen clamp on the flatband .. pull out, reseat and tighten clamp) also a cold solder joint may cause such things (inspect solder spots around the flat cable) good luck dg9bfc sigi Am 04.03.2023 um 17:32 schrieb Igor - PY3IG: A user has the nanovna H4 with this display defect. Suggestions before switching to a new display? |
Re: New user to H4 model
Steve Bowers
Awesome. Much obliged!
toggle quoted message
Show quoted text
Thanks Steve On Mar 4, 2023, at 7:11 PM, robert miles <bob@...> wrote: |
Re: NanoVNA-App in app calibration problem (bug?)
#calibration
#nanovna-app
i measured a patch antenna for 13cm with nanovna app and with calibration in the device and in nanovna app and if i compare smith of nanovna app and smith in the unit .. they look quite similar (if not exactly the same) ...
toggle quoted message
Show quoted text
and measure a 13cm circular polarized antenna is not that easy (on 13 cm every adaptor can be seen in smith) but ... the unit uses the avg setting on boot that you have saved in slot 0 (first slot) if you have a low setting there .. then also measure via app is done with a low average number and so calibration is not "smooth" ... (in other words calibration data has noise in it) you want a high avg number (many measured and averaged points per step) ... then do a calibration (say 5 to 10 runs) ... and save that file now you can set avg low in slot 0 (say avg2) ... so when using the software scanning goes a bit faster at 400 points per second avg setting in unit and avg setting in the soft are two different things (averaging in calibration is a third one .. grin) so what i do is ... at first i do a slow run (high avg setting in device) to search my correction values (others say do a calibration) after that i set avg lower (to have a faster readout while tuning an antenna or whatever) ... same thing for calibrating the software i first save a high avg number in slot 0 (yes then also scanning in the soft is slower!!) .. do the calibration run .. save that file ... reload it (to make it active) ... then save a lower avg number in slot 0 and do my measurements ... its a bit tricky to understand that (how does avg in the device correspond with avg in soft?!?) i try an easy example calibration in device ... avg set to x5 ... say we do 1 meg steps and only a few (just an example!!) devide does make stepping as follows 1,1,1,1,1,2,2,2,2,2,3,3,3,3,3,4,4,4,4,4,5,5,5,5,5... etc etc (so each point is done 5 times before stepping to next one ... noise is calibrated out that way cause noise is random) calibration run then also uses 5 values for each point (BEFORE STEPPING TO NEXT!!) calibration with average in the soft is a bit different avg in calibration goes (say 5 steps and x5 avg) 12345,12345,12345,12345,12345 (and then save that file after you did those 5 runs with open short and load) it is different if you measure a value 5 times beore you step to the next ... or if you do 5 times the same 12345 run (and average those 5 runs) i used easy examples (only 5 steps and not 401) just to show the principle and differences) no idea if any of you understand all my rubbish hi hi ... but .. i can do NOT find any faults here comparing nano app ... and the device itself IF I DO THE CALIBRATION CORRECT WAY!!! (means above procedure ... use high avg IN THE UNIT first .. save file, activate and then go from there) only v2plus4 is a bit different ... even with lower avg number it is not as noisy cause the averaging is done in the bootloader and not in main fw (dislord may better explain how all these things interact and i do not know how it is done in the newer lite vna or other newer units) dg9bfc sigi Am 04.03.2023 um 04:42 schrieb Roger Need via groups.io: On Fri, Mar 3, 2023 at 05:54 PM, Siegfried Jackstien wrote:if you calibrate the cable out then all should show near similar resultsThis was a comparison of how well each one calibrated the same cable and measured a 1K DUT. A new calibration using the same cal loads was done at the end of the 3M cable for each test and then they were compared. The results for NanoVNA App, NanoVNA Saver and Standalone VNA should all be very close because they all are all calibrated the same and used the same 1K SMD resistor as the DUT. Averaging was not used in these tests - just one sweep. |
Re: DiSlord build 1.2.19, saved cal files give error when reading
1.3.15 is most actual
toggle quoted message
Show quoted text
(what hw you have??) dg9bfc sigi Am 05.03.2023 um 02:27 schrieb TheSpud via groups.io: Because of the problems with 1.2.14 missing the read from SD menu, I downloaded 1.2.19 and attempted to save my cal files again. They saved without errors, but when I try to read them I get format error. |
DiSlord build 1.2.19, saved cal files give error when reading
Because of the problems with 1.2.14 missing the read from SD menu, I downloaded 1.2.19 and attempted to save my cal files again. They saved without errors, but when I try to read them I get format error.
Please advise what is most recent version that supports writing and reading from the SD card. Thanks |
Re: New user to H4 model
I found the youtube videos by W2AEW on the nanovna to be excellent. ?He does one on updating the H4 from a dfu file
toggle quoted message
Show quoted text
#320: How to update the NanoVNA-H4 firmware using Windows 10 and .DFU file ( ) youtu.be ( ) ( ) Coupled with the beginners guide supplied by Roger et al it should get you going. Regards Bob GM4CAQ
|
Re: Driver for nanVNA
I have determined that the problem is with the nanoVNA device. It will not
toggle quoted message
Show quoted text
communicate with any of my PCs. I have two with Windows 10 and one with Windows 7. The nanoVNA works well as stand alone, but will not communicate with a computer. Thanks to all for the help that you have been!! David On Thu, Mar 2, 2023 at 2:46?PM robert miles <bob@...> wrote:
Hi david |
Re: New user to H4 model
Steve Bowers
That¡¯s great! Much obliged!
toggle quoted message
Show quoted text
Thanks Steve On Mar 4, 2023, at 12:39 PM, Roger Need via groups.io <sailtamarack@...> wrote: |
Re: New user to H4 model
On Sat, Mar 4, 2023 at 09:24 AM, Steve Bowers wrote:
I put a copy of the Absolute Beginner's Guide on my Box account for you to download. Download button in upper right hand corner. Here is the link. Roger |
Re: New user to H4 model
Steve Bowers
I¡¯m trying but I¡¯m getting some erratic information. I¡¯m sure it¡¯s user error.
toggle quoted message
Show quoted text
Thanks Steve On Mar 4, 2023, at 12:15 PM, Chris Gardner via groups.io <seaman98@...> wrote: |
Re: H4 display defect
Greetings, One quick and easy check is to make sure that the front and back halves of the case aren¡¯t too tight putting excessive pressure on the display. Try loosening the screws see if the issue subsides
toggle quoted message
Show quoted text
On Mar 4, 2023, at 11:32, Igor - PY3IG <igor.jobim@...> wrote: |
Re: New user to H4 model
No problem, enjoy your H4!
toggle quoted message
Show quoted text
On Mar 4, 2023, at 11:17, Steve Bowers <bowxyz@...> wrote: |
Re: New user to H4 model
Awesome!! Much obliged!!!
toggle quoted message
Show quoted text
Thanks Steve On Mar 4, 2023, at 10:57 AM, Chris Gardner via groups.io <seaman98@...> wrote: |
Re: New user to H4 model
Greetings, May I suggest that you obtain a copy of this document (Absolute Beginners Guide). I am sure you will find the information there.
toggle quoted message
Show quoted text
Log In ( /g/nanovna-users/files/Absolute%20Beginner%20Guide%20to%20The%20NanoVNA/Absolute_Beginner_Guide_NanoVNA_v1_5.pdf ) groups.io ( /g/nanovna-users/files/Absolute%20Beginner%20Guide%20to%20The%20NanoVNA/Absolute_Beginner_Guide_NanoVNA_v1_5.pdf ) apple-icon-180x180.png ( /g/nanovna-users/files/Absolute%20Beginner%20Guide%20to%20The%20NanoVNA/Absolute_Beginner_Guide_NanoVNA_v1_5.pdf ) ( /g/nanovna-users/files/Absolute%20Beginner%20Guide%20to%20The%20NanoVNA/Absolute_Beginner_Guide_NanoVNA_v1_5.pdf ) 73¡¯²õ
|
to navigate to use esc to dismiss