Re: NanoVNA USB C connector is stuck
Sorry, this reply was meant to be for a SMA connector. Jos Op 19-7-2020 om 18:21 schreef Jos Stevens:
By
Jos Stevens
·
#15438
·
|
Re: nanoVNA vs nanoVNA-F vs nanoVNA-H What is the difference??????
In short... Variant -H is the base 2.8" version. There are earlier h/w revisions, such as Hugen's original spin (black PCB + shielding) and the many clones of this. These should all be considered
By
Gerry Kavanagh
·
#15437
·
|
Re: SMA Torque Wrench
You're going to need something *Very Much* better than even the best NanoVNA to do those tests! Horses for courses, why would you use a ?50 "analyser" (that does work amazingly well) for any really
By
Dave_G0WBX
·
#15436
·
|
Red digit in the input field of the keaypad
Which is the aim behind the presentation of the data (sometimes with a red digit) in the input field of the keypad on the NaoVna H4 (fw version 0.5.0)? It seems they are always integers. And if a real
By
PE0CWK
·
#15435
·
|
Re: Intro and Noob Question
Hi Charles. Nanovna-saver is a Python app which runs pretty much everywhere. I run it on Fedora Linux but any fairly modern Linux will work. Just visit github and choose the download/install method
By
mike.carden
·
#15434
·
|
Intro and Noob Question
Greetings, all... I've been reading this group for a while now and today I took the plunge and ordered a NanoVNA-H4. Should be here in about a week. And I'm not the most patient guy in the world when
By
Charles Albert
·
#15433
·
|
Re: Determination of Soil Characteristics with Nanovna
Roger, Do you mean get the actual numbers that apply? Instead of the numbers you wish for? Just semantics - in this case significant. 73 de KEoZUW - John
By
John Nicholas
·
#15432
·
|
Re: SMA Torque Wrench
At HF frequencies, all this hand-wringing is of no consequence. Tighten the SMA connectors finger tight and get on with your measurements. I did microwave engineering (1-100 GHz) for many years. 73,
By
Carey Fisher
·
#15431
·
|
Re: NanoVNA Saver 0.3.3 or 0.3.4
Thank you Gyula and all the rest that replied. I managed to get Python loaded onto my shack computer and then I ran into another problem. Right now I¡¯m not sure what it was. However, a friend of
By
Joe Joncas
·
#15430
·
|
Re: Vertical OFFSET
#consolecommands
#improvement
#firmware
#measurement
#nanovna-h4
Kees, Personally, I am happy with the present scheme for the Reference Position. Regarding the red digit on the data entry line: More recent firmware versions seem to behave differently. Try some out
By
John Gord
·
#15429
·
|
Re: Determination of Soil Characteristics with Nanovna
Not sure if this is helpful or not, but I have and use a "fall of potential" ground resistance meter to check my ground restivity. It uses a built in AC oscillator driving 3 electrodes with a given
By
Ray, W4BYG
·
#15428
·
|
Re: NanoVNA Saver 0.3.3 or 0.3.4
Thank you wrote:
By
Clyde Spencer
·
#15427
·
|
Re: SMA Torque Wrench
Reading the original Military Specification for the SMA stated 3 inch pounds for Brass SMAs. It also limited mates/demates to 500 per pair. So if you are attaching to a PCB mounted unit, that one also
By
John Nicholas
·
#15426
·
|
Re: SMA Torque Wrench
How about someone in the group runs some tests on the electrical properties of the SMA connector torqued, finger tight and partially torqued? John, W?ZI
By
John Morphet
·
#15425
·
|
Re: SMA Torque Wrench
Some research indicates this idea has support elsewhere in the industry: https://www.maurymw.com/pdf/datasheets/5A-011.pdf
By
namerati@...
·
#15424
·
|
Re: SMA Torque Wrench
Not sure what you're talking about, Amazon has them for pennies on the dollar! https://www.amazon.com/3-5mm-connector/s?k=3.5mm+connector The nomenclature-related confusion potential is presumably one
By
namerati@...
·
#15423
·
|
Re: NanoVNA Saver 0.3.3 or 0.3.4
Clyde Unzip this file: https://github.com/NanoVNA-Saver/nanovna-saver/releases/download/v0.3.6/NanoVNASaver.windows-latest.zip The exe file is in folder Enrique
By
Enrique A. Wembagher LU8EFF
·
#15422
·
|
Re: Determination of Soil Characteristics with Nanovna
The soil conductivity and permittivity change with frequency and over a very small area. Rudy Sevens wrote a paper on how to model a low dipole over ground and then change the ground characteristics
By
Roger Steyaert <k7rxv@...>
·
#15421
·
|
Re: NanoVNA firmware user interface mod
#mods
Great, now you can set minimum and maximum in SWR, now it works. There are also many markers, more than three. It is perfectly. I only use this program. it is very stable, I would say, it works for me
By
DMR <bryonikater@...>
·
#15420
·
|
Re: Vertical OFFSET
#consolecommands
#improvement
#firmware
#measurement
#nanovna-h4
John, Thanks. Nice to read that it is possible what I was looking for. Sure. I discovered that it is possible to position the reference point not only on the gridlines, but also between them. However
By
Kees <bostulpje@...>
·
#15419
·
|