Keyboard Shortcuts
ctrl + shift + ? :
Show all keyboard shortcuts
ctrl + g :
Navigate to a group
ctrl + shift + f :
Find
ctrl + / :
Quick actions
esc to dismiss
Likes
- Nanovna-Users
- Messages
Search
Re: 4" H4 arrived
On Wed, Jan 22, 2020 at 11:41 AM, Jos Stevens wrote:
" ..I misread the date, sorry abt that, 18/01/2020 is the latest firmware indeed for the -H and the -H4..." ================================================ Jos, I've done that on more than one occasion. The group members are usually pretty quick to fill in my blind spot for me. Regarding your other question about the Menu Structure Map, it looks like in the haste to release the NanoVNA-H4 the map for the NanoVNA-H v.3.4 was included as an after thought. The worst error in the map, with regards to the H4, is the CONFIG->DFU sub-menu. This has been replaced with the BRIGHTNESS sub-menu and entering the DFU mode is now done by holding down the multi-function switch while powering on the H4, and then releasing. If you discover any special H4 related functions while putting it through its paces be sure to let the rest of us know. - Herb |
Re: SMITH CHART REACTANCE LINES.
Please desist from adding to this particular OT branch on this thread. I will terminate the thread if this branch continues, as the thread itself, on topic, is useful but this branch is not.
toggle quoted message
Show quoted text
If you wish to pursue the topic concerning edited messages, please start a new thread. DaveD, owner/moderator On Jan 22, 2020, at 14:55, Vince Vielhaber <vev@...> wrote: |
Re: We started selling nanoVNA-H4 using STM32F303CCT6 and 4-inch LCD
Can anyone tell me if the font is any bigger on the 4" over the 2.8"? I know the screen is bigger, but is the font bigger, or is it the same?
And yes, I know there is another firmware vers with bigger fonts.... but I'd like to keep the current firmware if I get it. -- Regards, Chris |
Re: Corrupted firmware.
Please review this Wiki page:
/g/nanovna-users/wiki/drivers#Cannot-load-new-firmware3AC2A0-STM32-BOOTLOADER After any recommended changes, the main Wiki page will be updated to point at it |
Re: SMITH CHART REACTANCE LINES.
Vince Vielhaber
One reason I can see for it being done is those of use that get the messages via email have no idea why someone edited or what they changed. All we get is a number of copies of seemingly the same message, often because someone missed a comma or period, or mis-spelled a word. Nothing in the email tells what was changed. It just says that it was edited.
toggle quoted message
Show quoted text
Vince - K8ZW. On 01/22/2020 12:25 PM, Larry Rothman wrote:
The owners of the group disabled the editing feature for some unknown reason.This forces you to copy the contents of the original message, which is then deleted and then you create and paste to a new message to edit.Or - just create yet another message and clutter up the forum, which is now over 10,000 messages!! --
K8ZW |
Re: 4" H4 arrived
Hi Herb,
toggle quoted message
Show quoted text
You are right , my fault, there isn't, I misread the date, sorry abt that, 18/01/2020 is the latest firmware indeed for the -H and the -H4. That is one of my questions, the compatibility of the firmware, if I remember well , I read in one of the posts that Hugen wanted to keep the firmware compatible , but I think? the posibilities of the CPU should be used. Best regards Jos Op 22-1-2020 om 20:14 schreef hwalker: On Wed, Jan 22, 2020 at 10:52 AM, Jos Stevens wrote: |
Re: Corrupted firmware.
Hi Brian -
These instructions1) .. are incomplete, in that many will need to install the appropriate STM drive. 2) There is already an entry at /g/nanovna-users/wiki#Help "check for wrong driver" |
Re: 4" H4 arrived
On Wed, Jan 22, 2020 at 10:52 AM, Jos Stevens wrote:
" I know there is a version dated 25/01/2020 for the -H " ============================================= Where do you see the version dated 25/01/2020 for the -H? The latest releases are at and I do not see that version there. Matter of fact, the 25th of January is not for another 3 days. Please note that there are separate releases for the NanoVNA-H4 and NanoVNA-H. They use different processors and displays so the firmwares are not interchangeable. - Herb |
Re: 4" H4 arrived
Hi Hugen,
toggle quoted message
Show quoted text
Yesterday I received the NanoVNA-H, very nice device. The NanoVNA Menu Structure Map that was included did not match the actual structure, I saw more menu items. is there a document that describes the H4 as it is ? Another question , the device came with firmware dated 18/01/2020 loaded , I know there is a version dated 25/01/2020 for the -H version can I use it for the H4 as well? or do I loose extra functionalities ? In Github I see the? H4 version dated 18/01/2020 as the latest ! Thanks in advance, Jos Op 21-1-2020 om 11:00 schreef hugen@...: In NanoVNA-H4, you can modify the display format of the SIMTH chart through the menu "MARKER" ¡ú "SMITH VALUE". |
Re: Corrupted firmware.
I wanted to document a solution to this problem that I found on the Wilderness Labs website. I will quote their steps directly so that we have an archive of the STM32 BOOTLOADER driver issue:
1) Connect your device in bootloader mode. 2) Open Device Manager 3) Find Universal Serial Bus devices > STM32 BOOTLOADER 4) Right-click STM32 BOOTLOADER and select Uninstall Device 5) In the Uninstall Device window, check Delete the driver software for this device, and click Uninstall 6) After uninstall is complete, the device will appear as STM Device in DFU mode under Universal Serial Bus controllers. 7) Reconnect the device in bootloader mode. These instructions and photo came (with permission) from the following web page: 73, Brian |
Re: SMITH CHART REACTANCE LINES.
On Wed, Jan 22, 2020 at 08:54 PM, hwalker wrote:
.... (and probably most casualMaybe, but I 'm not sure. However, thank you for your answer. As for me, I would be absolutely happy if this little line R+/-jX appeared on the NanoVNA-H screen. ))) 73! |
Re: SMITH CHART REACTANCE LINES.
On Wed, Jan 22, 2020 at 09:19 AM, Andy UA3RAW wrote:
Oristo wrote: I very much appreciate being able to select my 10kHz - 1 MHz stimulus calibration and e.g. check components or capacitance of short cables on the Smith chart display So am I. ))) But what is the problem to display an additional line with R+/-jX as on NanoVNA-Q screen on the screenshot below. Maybe because of memory limit? ============================================================ Andy, For designing matching networks I also prefer the R+/-jX format but the majority of the time, as commented by Oristo , I (and probably most casual users), use the NanoVNA-H to check components and sweep networks. Fortunately, whatever your preference, there is a firmware version out there that meets it (see message #9989). You are correct that because of flash memory space each firmware designer has to pick and choose what features they include. The NanoVNA-H4 has twice the flash memory of a NanoVNA-H and should be future proofed from this limitation for a while. A while should be translated as until every additional feature under the sun is added. - Herb - Herb |
Re: SMITH CHART REACTANCE LINES.
Because the edited (an re-edited and re- re-edited ...) messages add nothing but noise to the list. It¡¯s better to make sure one¡¯s post is as desired before posting than it is to re-post the message multiple times
toggle quoted message
Show quoted text
DaveD, owner/moderator On Jan 22, 2020, at 12:10, Andy UA3RAW <ua3raw@...> wrote: |
Re: SMITH CHART REACTANCE LINES.
The owners of the group disabled the editing feature for some unknown reason.This forces you to copy the contents of the original message, which is then deleted and then you create and paste to a new message to edit.Or - just create yet another message and clutter up the forum, which is now over 10,000 messages!!
toggle quoted message
Show quoted text
On Wednesday, January 22, 2020, 12:11:03 p.m. GMT-5, Andy UA3RAW <ua3raw@...> wrote:
Sorry for off topic, but why there is no abbility to edit messages in this group as in the others? It's a great inconvenience. ((( |
Re: *** FIX FOR NANOVNA-SAVER PYQT5 INSTALLATION PROBLEMS ON LINUX MINT 19.3 ***
#nanovna-saver
On Wed, Jan 22, 2020 at 02:49 AM, Nick wrote:
"Wheels are the standard Python packaging format for pure Python or binaryThanks Nick. The 64-bit wave is rolling over us :-) We can move on. Your install worked great on the 64-bit computer and the effort is much appreciated. 73, Bob |
Bob Albert
I removed my connector because of factory error, solder bridge, that shorted the 5V supply.? I would love to put it back but it's too difficult.? I may retrofit a different connector.
toggle quoted message
Show quoted text
I just don't have the visual acuity, steady hand, and tiny soldering tool needed. Bob On Wednesday, January 22, 2020, 09:17:31 AM PST, <roncraig1@...> wrote:
Putting a USB-C to USB-mini adaptor would only extend a stiff level arm to the connector making it more likely to put more stress on USB C socket. If it is still working and you want to improve things, add more solder to the shell ground connections at PCB to beef them up.? Be careful not to put so much solder that it possibly wicks into inner part of shell which would interfere with plug insertion. Use leaded solder if you can.? Most assembly houses these days use lead free solder which is more prone to fracturing then leaded solder.? Europe is very strict about using leaded solder and will block any supplier that ships their device with leaded solder. Changing the connector is difficult.? You need a very small solder tip and very steady hands.? Sometimes it is better to just allow solder to bridge the connection pads and use solder wick after to clean it up and remove solder bridges. |
Re: SMITH CHART REACTANCE LINES.
On Wed, Jan 22, 2020 at 08:04 PM, Oristo wrote:
I very much appreciate being able to select my 10kHz - 1 MHz stimulusSo am I. ))) But what is the problem to display an additional line with R+/-jX as on NanoVNA-Q screen on the screenshot below. Maybe because of memory limit? |
to navigate to use esc to dismiss