John,
Thank you for your advice; I think that is the reason for the fault. I tried that and operated the unit outside of the case and it seemed to work a little better but the menu still flickered and jittered. I also noted that, after a full charge, the battery discharged rapidly -- after about 10 minutes of use. Apologize for not searching the group for an answer, but what battery could be used and how would it be replaced? Thank you again. -- William, k6whp -------------------- "Cheer up, things could get worse. So I cheered up and things got worse." |
Re: NanoVNA H FW 1.0.53 Display Intermittent
William,
toggle quoted message
Show quoted text
Also check for battery swelling causing pressure on the display. --John Gord On Thu, Apr 3, 2025 at 10:29 AM, k6whp wrote:
|
Re: Measuring Capacitors
Internally-matched power transistors use the internal bond wires as high-Q inductive elements. In conjunction with MOS capacitors they are used to build matching networks inside the package to bring the sub- to few-Ohm transistor impedances to something more manageable, or in some cases directly to 50 Ohm, at the device leads. The number of wires and their length, height and spacing determine their values, so are tweaked for tuning.
The devices' parasitic capacitances are absorbed into the matching network, making a useful element out of what was a hindrance. 73, Don N2VGU |
Re: NanoVNA H FW 1.0.53 Display Intermittent
William,
toggle quoted message
Show quoted text
This might be due to the case pressing on the touchscreen Try loosening the mounting screws or perhaps adding thin washers for spacing. --John Gord On Thu, Apr 3, 2025 at 10:29 AM, k6whp wrote:
|
NanoVNA H FW 1.0.53 Display Intermittent
Have an old NanoVNA H with the above FW whose display is intermittent. More specifically, the menu turns off and on or will revert to the main menu.
I have tried to do the touch cal and touch test with no success. Appreciate any remarks on the subject; resetting the unit, etc. Thanks in advance. -- William, k6whp -------------------- "Cheer up, things could get worse. So I cheered up and things got worse." |
Re: NANO VNA H4 , Implausible measurement results?
Hi, Brian,
toggle quoted message
Show quoted text
I still have mine with the matching speaker. Mine is an NC-183, not an NC-183D. Like you, I really loved that thing. Even now, the sight of it here brings back good memories. But I haven't used it for awhile as I've been using an R-388 I built up from parts in the mid-'70s. Even more, I use a Halli S-40B, a good compromise between weight and performance. The weight matters more to me at age 82 than is did a few decades ago. 73, Maynard W6PAP On 4/3/25 08:54, Brian Beezley wrote:
On Thu, Apr 3, 2025 at 08:40 AM, Maynard Wright, P. E., W6PAP wrote:Maynard, I bought a NC-183 to replace my S-38D in the early 1960s. I just loved that big receiver. |
Re: NANO VNA H4 , Implausible measurement results?
On Thu, Apr 3, 2025 at 08:40 AM, Maynard Wright, P. E., W6PAP wrote:
Maynard, I bought a NC-183 to replace my S-38D in the early 1960s. I just loved that big receiver. Brian |
Re: NANO VNA H4 , Implausible measurement results?
Hi, Ed,
toggle quoted message
Show quoted text
That's true! I remember hearing the phrase "you can work the world with watt and a wet noodle," but I didn't fully understand what was going on at the time. I did cut an old broadcast receiver chassis in half, use the three tube sockets for a 6AG7, a plate coil, crystals, and leads to the hand key and it put out, I think, about a watt or two and I had fun powering it from my NC-183. I mounted a meter on the chassis for tuning. It's still in the attic somewhere. I used a circuit from the 1952 ARRL Handbook, using a parallel resonant circuit with one variable instead of ARRL's pi-network. That would have been in 1958 when I bought the NC-183. Before that I had an S-38E and borrowing power from that would have been more difficult. I don't think that I would have been competent enough to build a power supply from scratch so the auxiliary socket on the NC-183 was pretty handy. 73, Maynard W6PAP On 3/31/25 09:57, AG6CX via groups.io wrote:
Maynard and others: |
Re: Measuring Capacitors
On Thu, Apr 3, 2025 at 08:11 AM, alan victor wrote:
I had guessed the DC block above SRF might be useful even when C was not the LF value. Thanks for the insight on R and L, Alan. Brian |
Re: Measuring Capacitors
Well.....here's another one for you: SM inductors. Most of the suppliers
quote Q at 1 MHz. 1) The RF "resistance" (due to skin effect) should be used instead of the DC resistance. 2) Outside of RFI suppression, who really uses them at 1 MHz. Where are the plots of Q vs. frequency? Or RF "resistance" vs. frequency? This is why I always source MuRata who gets it right. CoilCraft? No. Dave - W?LEV On Wed, Apr 2, 2025 at 10:34?PM Brian Beezley via groups.io <k6sti= [email protected]> wrote: By coincidence, I just added an image showing capacitance and dissipation-- *Dave - W?LEV* -- Dave - W?LEV |
Re: Measuring Capacitors
On Wed, Apr 2, 2025 at 03:34 PM, Brian Beezley wrote:
This is common practice in microwave power amplifiers and and some MMIC designs as one component brings in two. The R and L for above SRF of the C serves as a DC block while adding a stabilizing R and an L for the match. The same tactic is used with distributive L. First glance at some PA designs will most likely not make sense without recognizing that the parasitic is used to advantage. A complete sim is required adding in all device models including the passives. |
Re: Measuring Capacitors
On Thu, Apr 3, 2025 at 06:21 AM, Jim Lux wrote:
That's what I finally guessed designers must do. Check out the Y21 method plot for capacitance I just posted for a different capacitor. Above the first two resonances, capacitance returns to a positive value, though not the LF or rated value. Brian |
Re: Measuring Capacitors
On Wed, Apr 2, 2025 at 08:14 PM, Jim Lux wrote:
After looking at more .s2p capacitor files, I've concluded that the file comments refer to the measurement frequency range, not the recommended frequency range for the part. I've attached S-parameters for an 82 pF porcelain capacitor that are pretty wild. Capacitance calculated with the S21 and Y21 series-through methods differ greatly. Brian |
Re: Measuring Capacitors
To elaborate on this a bit. Let’s think about a standard 0602 sized part - that’s 0.06” long or about 1.5 mm. A piece of wire that long has an inductance of about 1.5 nH.
toggle quoted message
Show quoted text
With, say, 33 pF, that’s resonant at 715 MHz. And yet, such parts are regularly used in all sorts of circuits at higher frequencies. You just design for the parasitic values. On Apr 2, 2025, at 20:14, Jim Lux via groups.io <jimlux@...> wrote: |
Re: Measuring Capacitors
The max frequency is probably more about where losses get too big.
toggle quoted message
Show quoted text
And they’ll measure for a very wide range. Most design tools can deal with staying away from the SRF, if supplied with the part parameters. After all, at microwave frequencies most parts have a very complex and varying impedance. On Apr 2, 2025, at 15:34, Brian Beezley <k6sti@...> wrote: |
Re: Jittery , non steady readings
Yes, it is
Zack W9SZ On Wed, Apr 2, 2025, 4:12 PM Dave Brown via groups.io <2c39a= [email protected]> wrote: Is the measurement frequency stable? |
Re: Measuring Capacitors
By coincidence, I just added an image showing capacitance and dissipation factor plotted by my S-parameter plotter. It was derived from an .s2p file provided by Kyocera. Scroll to the last image:
One thing I don't understand. Manufacturers specify useful frequencies several times the capacitor self-resonant frequency, as revealed by the .s2p files they supply. The 33 pF shown departs from 33 pF as it approaches its 1.6 GHz SRF, which is nowhere near the 10 GHz specified upper frequency limit. All the capacitor manufacturers seems to do this. Why? Brian |
Re: Jittery , non steady readings
Is the measurement frequency stable?
toggle quoted message
Show quoted text
Dave ZL3FJ -----Original Message-----
From: [email protected] [mailto:[email protected]] On Behalf Of Zack Widup via groups.io Sent: Thursday, April 03, 2025 06:14 To: [email protected] Subject: Re: [nanovna-users] Jittery , non steady readings I have consistently had this problem measuring inductors, capacitors and resistors. Just recently I measured a silver mica capacitor that was around 3400 pF. I measured at 475 kHz (630 meter amateur band). As I watched the display, every time I got a new measurement I would see something like 3420.1 3416.3 3411.8 3418.6 3422.5 3424.2 etc. I took the average of the measurements as the value. But I don't know why this was happening. The same happens with resistors and inductors. I could see the inductors as most likely to pick up radio signals. But I do not live close to a radio station or any service that is transmitting near me (as noted on a TinySA). I turned off my wifi and got the same results. I use a right angle SMA connector with a wire about 3 inches long going through the opening and soldered to the center pin contact, also another wire about 3 inches long soldered to the SMA body. I solder the other ends of the wires to the device under test. Zack W9SZ On Tue, Apr 1, 2025 at 2:51?PM kellogs via groups.io <mihai0226= [email protected]> wrote: Is it normal for the readings to fluctuate as much as 2-3 ohms ? As in<> Virus-free.www.avg.com <> <#DAB4FAD8-2DD7-40BB-A1B8-4E2AA1F9FDF2> |