Re: NanoVNA H / H4 / V2 / V2Plus / V2Plus4 firmware v1.0.69 #firmware

 

Obviously you haven't since the emails keep coming.

On Mon, 16 Aug 2021 at 13:15, Knud Jorgen Olsen-Jensen via groups.io
<vk2kjj@...> wrote:

Stop sending the e-mail to me. I have even left the Group because I could
not stop the mails

CW4EVER

On 16 Aug 2021, at 19:31, Anton <om1aeg@...> wrote:

?Thank you for your reply DiSlord. I looked at both PCBs, 10R resistor
for 3.3V I put in position R2 on "LCD" PCB, MOSI signals, MISO, SCLK are
available on H1 connector on "LCD" PCB. The problem will be to get the PB9
(CS) signal out of U303:46, directly from U303 pin, no trace on PCB.









Re: Measuring Unknown #matching #transformer

 

See the bottom of each email for the link

On Aug 15, 2021, at 20:10, Knud Jorgen Olsen-Jensen via groups.io <vk2kjj@...> wrote:

?Don¡¯t send me your emails

CW4EVER

On 16 Aug 2021, at 09:15, Charles KC6UFM <kc6ufm@...> wrote:

?Hi, Luciano...

I more or less (in my head) wrote off the "extra" resistance needed to make
the NanoVNA see a flat match as being to a combination of lead
resistance/reactance and operator error.

I think it's safe to assume that the transformer is actually a 49:1 ratio.

Thanks!


On Sun, Aug 15, 2021 at 3:48 PM Luciano Luciano <luciano.wdc@...>
wrote:

Hi Charles,

I get "suspicious" when I see small differences like this i.e. 50 ohm as
in this case. Assuming the black box is lossless, you should measure either
2450 or 2500 ohm if you load the other port (with coax connector, right?)
with 50 ohm... if you measure 2450 then it is a 49:1 transformer as you
correctly guessed in the first place! Of course easier to say (and write)
in theory than to actually do in practice.

Regards,
Luciano


On Sun, Aug 15, 2021, 6:15 PM Charles KC6UFM <kc6ufm@...> wrote:

Hello, All...

I recently had a need to measure an unknown matching transformer. As it
was
in a sealed enclosure with noth but the wire terminal and coax connector
exposed, and I didn't want to damage the enclosure, I pulled out my
trusty
NanoVNA.

All I knew about the "black box" was that it was used with a
10-12-15-17-20m EFHW wire antenna. That made me assume it would be
somewhere in the range of a 49:1 ratio.

I pulled out my decade resistance box and dialed in 2450 ohms (50 ohms x
49) and put that between the output wire terminal and ground. I then
connected the NanoVNA to the coax input.

I then played with the decade box until I got a flat response from the
NanoVNA and the needed resistance to get there was 2501 ohms.
Technically,
that makes the matching network about 50:1 ratio.

All of this told me what I wanted to know, but I'm wondering if there
would
be an easier, more direct way of getting there with the NanoVNA.

I'm good with the idea that I may have just stumbled onto the right
answer
in my madness.

Take Care & 73

--
de KC6UFM
Charles









--
de KC6UFM
Charles








Re: NanoVNA H / H4 / V2 / V2Plus / V2Plus4 firmware v1.0.69 #firmware

 

Stop sending the e-mail to me. I have even left the Group because I could not stop the mails
You need go /g/nanovna-users/editsub and select No Email for disable receive group messages


Re: NanoVNA H / H4 / V2 / V2Plus / V2Plus4 firmware v1.0.69 #firmware

Knud Jorgen Olsen-Jensen
 

Stop sending the e-mail to me. I have even left the Group because I could not stop the mails

CW4EVER

On 16 Aug 2021, at 19:31, Anton <om1aeg@...> wrote:

?Thank you for your reply DiSlord. I looked at both PCBs, 10R resistor for 3.3V I put in position R2 on "LCD" PCB, MOSI signals, MISO, SCLK are available on H1 connector on "LCD" PCB. The problem will be to get the PB9 (CS) signal out of U303:46, directly from U303 pin, no trace on PCB.





Re: Download NanaoVNA Labview

 

From the NI MAX web site: "NI MAX is only supported on Windows and MacOS, not Linux, and cannot be downloaded by itself. It is included with all NI drivers (NI-VISA, NI-DAQmx etc.) and NI System Configuration."

73, Don N2VGU


Re: NanoVNA H / H4 / V2 / V2Plus / V2Plus4 firmware v1.0.69 #firmware

 

Thank you for your reply DiSlord. I looked at both PCBs, 10R resistor for 3.3V I put in position R2 on "LCD" PCB, MOSI signals, MISO, SCLK are available on H1 connector on "LCD" PCB. The problem will be to get the PB9 (CS) signal out of U303:46, directly from U303 pin, no trace on PCB.


Re: Measuring Unknown #matching #transformer

Knud Jorgen Olsen-Jensen
 

Don¡¯t send me your emails

CW4EVER

On 16 Aug 2021, at 10:10, Knud Jorgen Olsen-Jensen via groups.io <vk2kjj@...> wrote:

?Don¡¯t send me your emails

CW4EVER

On 16 Aug 2021, at 09:15, Charles KC6UFM <kc6ufm@...> wrote:

?Hi, Luciano...

I more or less (in my head) wrote off the "extra" resistance needed to make
the NanoVNA see a flat match as being to a combination of lead
resistance/reactance and operator error.

I think it's safe to assume that the transformer is actually a 49:1 ratio.

Thanks!


On Sun, Aug 15, 2021 at 3:48 PM Luciano Luciano <luciano.wdc@...>
wrote:

Hi Charles,

I get "suspicious" when I see small differences like this i.e. 50 ohm as
in this case. Assuming the black box is lossless, you should measure either
2450 or 2500 ohm if you load the other port (with coax connector, right?)
with 50 ohm... if you measure 2450 then it is a 49:1 transformer as you
correctly guessed in the first place! Of course easier to say (and write)
in theory than to actually do in practice.

Regards,
Luciano


On Sun, Aug 15, 2021, 6:15 PM Charles KC6UFM <kc6ufm@...> wrote:

Hello, All...

I recently had a need to measure an unknown matching transformer. As it
was
in a sealed enclosure with noth but the wire terminal and coax connector
exposed, and I didn't want to damage the enclosure, I pulled out my
trusty
NanoVNA.

All I knew about the "black box" was that it was used with a
10-12-15-17-20m EFHW wire antenna. That made me assume it would be
somewhere in the range of a 49:1 ratio.

I pulled out my decade resistance box and dialed in 2450 ohms (50 ohms x
49) and put that between the output wire terminal and ground. I then
connected the NanoVNA to the coax input.

I then played with the decade box until I got a flat response from the
NanoVNA and the needed resistance to get there was 2501 ohms.
Technically,
that makes the matching network about 50:1 ratio.

All of this told me what I wanted to know, but I'm wondering if there
would
be an easier, more direct way of getting there with the NanoVNA.

I'm good with the idea that I may have just stumbled onto the right
answer
in my madness.

Take Care & 73

--
de KC6UFM
Charles









--
de KC6UFM
Charles








Re: Measuring Unknown #matching #transformer

Knud Jorgen Olsen-Jensen
 

Don¡¯t send me your emails

CW4EVER

On 16 Aug 2021, at 09:15, Charles KC6UFM <kc6ufm@...> wrote:

?Hi, Luciano...

I more or less (in my head) wrote off the "extra" resistance needed to make
the NanoVNA see a flat match as being to a combination of lead
resistance/reactance and operator error.

I think it's safe to assume that the transformer is actually a 49:1 ratio.

Thanks!


On Sun, Aug 15, 2021 at 3:48 PM Luciano Luciano <luciano.wdc@...>
wrote:

Hi Charles,

I get "suspicious" when I see small differences like this i.e. 50 ohm as
in this case. Assuming the black box is lossless, you should measure either
2450 or 2500 ohm if you load the other port (with coax connector, right?)
with 50 ohm... if you measure 2450 then it is a 49:1 transformer as you
correctly guessed in the first place! Of course easier to say (and write)
in theory than to actually do in practice.

Regards,
Luciano


On Sun, Aug 15, 2021, 6:15 PM Charles KC6UFM <kc6ufm@...> wrote:

Hello, All...

I recently had a need to measure an unknown matching transformer. As it
was
in a sealed enclosure with noth but the wire terminal and coax connector
exposed, and I didn't want to damage the enclosure, I pulled out my
trusty
NanoVNA.

All I knew about the "black box" was that it was used with a
10-12-15-17-20m EFHW wire antenna. That made me assume it would be
somewhere in the range of a 49:1 ratio.

I pulled out my decade resistance box and dialed in 2450 ohms (50 ohms x
49) and put that between the output wire terminal and ground. I then
connected the NanoVNA to the coax input.

I then played with the decade box until I got a flat response from the
NanoVNA and the needed resistance to get there was 2501 ohms.
Technically,
that makes the matching network about 50:1 ratio.

All of this told me what I wanted to know, but I'm wondering if there
would
be an easier, more direct way of getting there with the NanoVNA.

I'm good with the idea that I may have just stumbled onto the right
answer
in my madness.

Take Care & 73

--
de KC6UFM
Charles









--
de KC6UFM
Charles





Re: Measuring S11 at input of RF power amplifier - could I calibrate "through" an attenuator?

 

On Sun, Aug 15, 2021 at 02:21 PM, Jim Lux wrote:



What's the ripple in the measurement from? A reduced SNR would give a
random error, not a periodic one, but maybe it's a manifestation of a
phase bias that is contributing more or less depending on the reflected
phase?
The attenuators affect more than S11 SNR when used in this fashion They are not exactly 50 ohms input/output impedance. Also the calibration errors will probably be greater as the DUT impedance is further away from 50 ohms.

Roger


Roger


Re: download the calibration from the NanoVNA

Knud Jorgen Olsen-Jensen
 

Don¡¯t send me your emails

CW4EVER

On 16 Aug 2021, at 09:17, DiSlord <dislordlive@...> wrote:

?Need use any console software (like terminal, putty RealTerm)

You receive list of error tetm (used by nanoVna as calibration data)
'data 2' ED - error term directivity
'data 3' ES - error term source match
'data 4' ER - error term refrection tracking
'data 5' ET - error term transmission tracking
'data 6' EX - error term isolation

But NanoVNA Saver Use SOLT calibration data format, so you can`t use this calibration data in it.





Re: download the calibration from the NanoVNA

 

Need use any console software (like terminal, putty RealTerm)

You receive list of error tetm (used by nanoVna as calibration data)
'data 2' ED - error term directivity
'data 3' ES - error term source match
'data 4' ER - error term refrection tracking
'data 5' ET - error term transmission tracking
'data 6' EX - error term isolation

But NanoVNA Saver Use SOLT calibration data format, so you can`t use this calibration data in it.


Re: Measuring Unknown #matching #transformer

Charles KC6UFM
 

Hi, Luciano...

I more or less (in my head) wrote off the "extra" resistance needed to make
the NanoVNA see a flat match as being to a combination of lead
resistance/reactance and operator error.

I think it's safe to assume that the transformer is actually a 49:1 ratio.

Thanks!


On Sun, Aug 15, 2021 at 3:48 PM Luciano Luciano <luciano.wdc@...>
wrote:

Hi Charles,

I get "suspicious" when I see small differences like this i.e. 50 ohm as
in this case. Assuming the black box is lossless, you should measure either
2450 or 2500 ohm if you load the other port (with coax connector, right?)
with 50 ohm... if you measure 2450 then it is a 49:1 transformer as you
correctly guessed in the first place! Of course easier to say (and write)
in theory than to actually do in practice.

Regards,
Luciano


On Sun, Aug 15, 2021, 6:15 PM Charles KC6UFM <kc6ufm@...> wrote:

Hello, All...

I recently had a need to measure an unknown matching transformer. As it
was
in a sealed enclosure with noth but the wire terminal and coax connector
exposed, and I didn't want to damage the enclosure, I pulled out my
trusty
NanoVNA.

All I knew about the "black box" was that it was used with a
10-12-15-17-20m EFHW wire antenna. That made me assume it would be
somewhere in the range of a 49:1 ratio.

I pulled out my decade resistance box and dialed in 2450 ohms (50 ohms x
49) and put that between the output wire terminal and ground. I then
connected the NanoVNA to the coax input.

I then played with the decade box until I got a flat response from the
NanoVNA and the needed resistance to get there was 2501 ohms.
Technically,
that makes the matching network about 50:1 ratio.

All of this told me what I wanted to know, but I'm wondering if there
would
be an easier, more direct way of getting there with the NanoVNA.

I'm good with the idea that I may have just stumbled onto the right
answer
in my madness.

Take Care & 73

--
de KC6UFM
Charles









--
de KC6UFM
Charles


Re: Measuring Unknown #matching #transformer

 

Hi Charles,

I get "suspicious" when I see small differences like this i.e. 50 ohm as
in this case. Assuming the black box is lossless, you should measure either
2450 or 2500 ohm if you load the other port (with coax connector, right?)
with 50 ohm... if you measure 2450 then it is a 49:1 transformer as you
correctly guessed in the first place! Of course easier to say (and write)
in theory than to actually do in practice.

Regards,
Luciano

On Sun, Aug 15, 2021, 6:15 PM Charles KC6UFM <kc6ufm@...> wrote:

Hello, All...

I recently had a need to measure an unknown matching transformer. As it was
in a sealed enclosure with noth but the wire terminal and coax connector
exposed, and I didn't want to damage the enclosure, I pulled out my trusty
NanoVNA.

All I knew about the "black box" was that it was used with a
10-12-15-17-20m EFHW wire antenna. That made me assume it would be
somewhere in the range of a 49:1 ratio.

I pulled out my decade resistance box and dialed in 2450 ohms (50 ohms x
49) and put that between the output wire terminal and ground. I then
connected the NanoVNA to the coax input.

I then played with the decade box until I got a flat response from the
NanoVNA and the needed resistance to get there was 2501 ohms. Technically,
that makes the matching network about 50:1 ratio.

All of this told me what I wanted to know, but I'm wondering if there would
be an easier, more direct way of getting there with the NanoVNA.

I'm good with the idea that I may have just stumbled onto the right answer
in my madness.

Take Care & 73

--
de KC6UFM
Charles






Re: download the calibration from the NanoVNA

 

I do not understand what you mean. Do you mean the nanovna-saver.exe window
(mostly black with some status lines on it: I am not able to do a command
from there)?
Or is there some console within the NanoVNA-Saver window?
Or do I need to start a cmd.exe window and then?

Thanks for any help.

All the best,

Victor

Op zo 15 aug. 2021 om 15:52 schreef DiSlord <dislordlive@...>:

Use console data command
data 2
data 3
....
data 6






Re: Download NanaoVNA Labview

Syd
 

I worked for PWA for decades and was the only engineer that used LabVIEW, now all the engineers do. It is very easy to learn (very friendly for EEs) and yes it is expensive. So I am glad to see that there is a free version of the IDE. National Instruments makes a huge profit from the hardware, not software, that it sells. Our department bought over $100, 000 worth of FPGA hardware a while ago. It is used world wide (CERN for one)! Having the commercial version installed on my laptop, now I'm curious just how much the free version can support for the budding developer, ie. can one develop an entire project or just a small VI? Does the version include MAX to experiment and simulate hardware devices instead of having to actually buy one? If this does included MAX, then one can make a project using simulated hardware devices in the Vi, and then simulate the device when running the VI.
wt1v


Re: Measuring a 1/4 wave balanced line #cables

 

Great! Thanks. Any google search I attempted lead me to the RSGB website, which was a dead end for me. I did realize the forums were right here on groups.io, duh.


Measuring Unknown #matching #transformer

Charles KC6UFM
 

Hello, All...

I recently had a need to measure an unknown matching transformer. As it was
in a sealed enclosure with noth but the wire terminal and coax connector
exposed, and I didn't want to damage the enclosure, I pulled out my trusty
NanoVNA.

All I knew about the "black box" was that it was used with a
10-12-15-17-20m EFHW wire antenna. That made me assume it would be
somewhere in the range of a 49:1 ratio.

I pulled out my decade resistance box and dialed in 2450 ohms (50 ohms x
49) and put that between the output wire terminal and ground. I then
connected the NanoVNA to the coax input.

I then played with the decade box until I got a flat response from the
NanoVNA and the needed resistance to get there was 2501 ohms. Technically,
that makes the matching network about 50:1 ratio.

All of this told me what I wanted to know, but I'm wondering if there would
be an easier, more direct way of getting there with the NanoVNA.

I'm good with the idea that I may have just stumbled onto the right answer
in my madness.

Take Care & 73

--
de KC6UFM
Charles


Re: Measuring a 1/4 wave balanced line #cables

 

[image: image.png]

This should get you started.

Dave - WLEV



On Sun, Aug 15, 2021 at 7:40 PM Lou W7HV via groups.io <louandzip=
[email protected]> wrote:

On Sun, Aug 15, 2021 at 12:26 PM, David Eckhardt wrote:


Owen's posts can also be accessed on the RSGB sites. I subscribe to both
the "antennas" and the "antennas research" sites from RSGB.
Did a quick search for RSGB sites as described but didn't have any luck.
Could you provide a link or more info to help find them?

TNX





--
*Dave - W?LEV*
*Just Let Darwin Work*


Re: Measuring S11 at input of RF power amplifier - could I calibrate "through" an attenuator?

 

On 8/15/21 12:37 PM, Roger Need via groups.io wrote:
On Sat, Aug 14, 2021 at 09:14 AM, David Feldman wrote:

If I insert (example) 6 dB pad between nanovna S11 port and amplifier input
port, and calibrate the nanovna (open-short-load) at the "far" end of the pad,
what impact would this have on S11 measurements?
Here are some S11 measurements I did "calibrating out" a 10 dB and a 20 db attenuator. Measurement errors get worse as you increase the attenuation but 6 dB won't be bad at all.

/g/nanovna-users/message/18145

Roger

What's the ripple in the measurement from? A reduced SNR would give a random error, not a periodic one, but maybe it's a manifestation of a phase bias that is contributing more or less depending on the reflected phase?


Re: Measuring S11 at input of RF power amplifier - could I calibrate "through" an attenuator?

 

On 8/15/21 12:06 PM, KENT BRITAIN wrote:
How does the output load become part of the S11 measurement?
I agree you need it to keep the amp happy, but when you make your?amplitude and phase measurements on the antenna tuner, the load should?not be part of that.? ? ? Kent G8EMY
on real amplifiers, with non zero S12, the load impedance does show up at the input - imagine an amplifier with S12 of -10 dB and a S11 of -100dB.? A total reflection at the output of the amp will make the S11 of the amplifier appear to be -10dB. With solid state stage gains for power amplifiers of 8-10dB, this isn't so unusual. As long as |S12|<|S21| the amplifier will probably be stable.


And on a non-amplifier case, if you have two antennas that have any mutual coupling (or for which you hope there's negligible coupling), the impedance connected to the feedpoint of antenna 2 affects the measured impedance of antenna 1.

I've been doing some measurements of just that - using only S11 measurements of the AUT.