Re: Is anyone working on a screen larger than 4.
Bird uses a 5.5" Samsung cellphone for the display and compute base of their SK4000 antenna analyzer series so it is possible.?I mentioned the SK4000 way back last September.
When you think about it, cho45's android app for the 'nano sort of replicates that in a crude way.? ... Larry On Wed, 22 Jan 2020 at 6:20 PM, Dr. David Kirkby, Kirkby Microwave Ltd<drkirkby@...> wrote: The screen size of the first NanoVNAs is barely usable unless people have very good vision. I know Hugen has a screen slightly less than 4¡±, and the NanoVNA-F has a 4.3¡± screen. Is anybody working on a version with a larger screen? One can get a mobile phone with a 5.5¡± capacitive touch screen for $28 from Amazon. -- Dr. David Kirkby, Kirkby Microwave Ltd, drkirkby@... Telephone 01621-680100./ +44 1621 680100 Registered in England & Wales, company number 08914892. Registered office: Stokes Hall Lodge, Burnham Rd, Althorne, Chelmsford, Essex, CM3 6DT, United Kingdom |
Is anyone working on a screen larger than 4.3 inches?
The screen size of the first NanoVNAs is barely usable unless people have
very good vision. I know Hugen has a screen slightly less than 4¡±, and the NanoVNA-F has a 4.3¡± screen. Is anybody working on a version with a larger screen? One can get a mobile phone with a 5.5¡± capacitive touch screen for $28 from Amazon. -- Dr. David Kirkby, Kirkby Microwave Ltd, drkirkby@... Telephone 01621-680100./ +44 1621 680100 Registered in England & Wales, company number 08914892. Registered office: Stokes Hall Lodge, Burnham Rd, Althorne, Chelmsford, Essex, CM3 6DT, United Kingdom |
Re: 4" H4 arrived
On Wed, Jan 22, 2020 at 01:08 PM, Larry Rothman wrote:
From Hugen's github F303 branch, starting at line 169, you can see the list of all the (current) on-screen menu commands: =================================================================== Here is a printout of those commands from the CLI: # NanoVNA-H4 # Commands: help exit info threads version reset freq offset time dac saveconfig clearconfig # data frequencies port stat gain power sample scan sweep test touchcal touchtest pause resume # cal save recall trace marker edelay capture vbat transform threshold vbat_offset - Herb |
Re: We started selling nanoVNA-H4 using STM32F303CCT6 and 4-inch LCD
On Wed, Jan 22, 2020 at 12:26 PM, Birdman wrote:
Can anyone tell me if the font is any bigger on the 4" over the 2.8"? I know the screen is bigger, but is the font bigger, or is it the same? And yes, I know there is another firmware vers with bigger fonts.... but I'd like to keep the current firmware if I get it. ===================================================== Birdman, You didn't mention which version you are currently using but the 4" NanoVNA-H4 uses different and incompatible firmware than the 2.8" Nano-VNA-H, so you will definitely not be able to keep your current firmware. If you are currently using hugen's firmware, then the H4's firmware will include everything you are currently using plus some additional functions. The fonts on the 4" NanoVNA-H4 are larger that the default 2.8" NanoVNA-H, but about the same size as the fonts used in the -AA (antenna analyzer) firmware. The 4" screen is brighter and the characters are more legible than those of the -AA firmware. Regards, - Herb |
Re: 4" H4 arrived
From Hugen's github F303 branch, starting at line 169, you can see the list of all the (current) on-screen menu commands:
toggle quoted message
Show quoted text
On Wednesday, January 22, 2020, 3:59:19 p.m. GMT-5, hwalker <herbwalker2476@...> wrote:
On Wed, Jan 22, 2020 at 11:41 AM, Jos Stevens wrote: " ..I misread the date, sorry abt? that, 18/01/2020 is the latest firmware indeed for the -H and the -H4..." ================================================ Jos, ? ? I've done that on more than one occasion.? The group members are usually pretty quick to fill in my blind spot for me. Regarding your other question about the Menu Structure Map, it looks like in the haste to release the NanoVNA-H4 the map for the NanoVNA-H v.3.4 was included as an after thought.? The worst error in the map,? with regards to the H4, is the CONFIG->DFU sub-menu.? This has been replaced with the BRIGHTNESS sub-menu and entering the DFU mode is now done by holding down the multi-function switch while powering on the H4, and then releasing. ? If you discover any special H4 related functions while putting it through its paces be sure to let the rest of us know. - Herb |
Re: 4" H4 arrived
On Wed, Jan 22, 2020 at 11:41 AM, Jos Stevens wrote:
" ..I misread the date, sorry abt that, 18/01/2020 is the latest firmware indeed for the -H and the -H4..." ================================================ Jos, I've done that on more than one occasion. The group members are usually pretty quick to fill in my blind spot for me. Regarding your other question about the Menu Structure Map, it looks like in the haste to release the NanoVNA-H4 the map for the NanoVNA-H v.3.4 was included as an after thought. The worst error in the map, with regards to the H4, is the CONFIG->DFU sub-menu. This has been replaced with the BRIGHTNESS sub-menu and entering the DFU mode is now done by holding down the multi-function switch while powering on the H4, and then releasing. If you discover any special H4 related functions while putting it through its paces be sure to let the rest of us know. - Herb |
Re: SMITH CHART REACTANCE LINES.
Please desist from adding to this particular OT branch on this thread. I will terminate the thread if this branch continues, as the thread itself, on topic, is useful but this branch is not.
toggle quoted message
Show quoted text
If you wish to pursue the topic concerning edited messages, please start a new thread. DaveD, owner/moderator On Jan 22, 2020, at 14:55, Vince Vielhaber <vev@...> wrote: |
Re: We started selling nanoVNA-H4 using STM32F303CCT6 and 4-inch LCD
Can anyone tell me if the font is any bigger on the 4" over the 2.8"? I know the screen is bigger, but is the font bigger, or is it the same?
And yes, I know there is another firmware vers with bigger fonts.... but I'd like to keep the current firmware if I get it. -- Regards, Chris |
Re: Corrupted firmware.
Please review this Wiki page:
/g/nanovna-users/wiki/drivers#Cannot-load-new-firmware3AC2A0-STM32-BOOTLOADER After any recommended changes, the main Wiki page will be updated to point at it |
Re: SMITH CHART REACTANCE LINES.
Vince Vielhaber
One reason I can see for it being done is those of use that get the messages via email have no idea why someone edited or what they changed. All we get is a number of copies of seemingly the same message, often because someone missed a comma or period, or mis-spelled a word. Nothing in the email tells what was changed. It just says that it was edited.
toggle quoted message
Show quoted text
Vince - K8ZW. On 01/22/2020 12:25 PM, Larry Rothman wrote:
The owners of the group disabled the editing feature for some unknown reason.This forces you to copy the contents of the original message, which is then deleted and then you create and paste to a new message to edit.Or - just create yet another message and clutter up the forum, which is now over 10,000 messages!! --
K8ZW |
Re: 4" H4 arrived
Hi Herb,
toggle quoted message
Show quoted text
You are right , my fault, there isn't, I misread the date, sorry abt that, 18/01/2020 is the latest firmware indeed for the -H and the -H4. That is one of my questions, the compatibility of the firmware, if I remember well , I read in one of the posts that Hugen wanted to keep the firmware compatible , but I think? the posibilities of the CPU should be used. Best regards Jos Op 22-1-2020 om 20:14 schreef hwalker: On Wed, Jan 22, 2020 at 10:52 AM, Jos Stevens wrote: |
Re: Corrupted firmware.
Hi Brian -
These instructions1) .. are incomplete, in that many will need to install the appropriate STM drive. 2) There is already an entry at /g/nanovna-users/wiki#Help "check for wrong driver" |
Re: 4" H4 arrived
On Wed, Jan 22, 2020 at 10:52 AM, Jos Stevens wrote:
" I know there is a version dated 25/01/2020 for the -H " ============================================= Where do you see the version dated 25/01/2020 for the -H? The latest releases are at and I do not see that version there. Matter of fact, the 25th of January is not for another 3 days. Please note that there are separate releases for the NanoVNA-H4 and NanoVNA-H. They use different processors and displays so the firmwares are not interchangeable. - Herb |
Re: 4" H4 arrived
Hi Hugen,
toggle quoted message
Show quoted text
Yesterday I received the NanoVNA-H, very nice device. The NanoVNA Menu Structure Map that was included did not match the actual structure, I saw more menu items. is there a document that describes the H4 as it is ? Another question , the device came with firmware dated 18/01/2020 loaded , I know there is a version dated 25/01/2020 for the -H version can I use it for the H4 as well? or do I loose extra functionalities ? In Github I see the? H4 version dated 18/01/2020 as the latest ! Thanks in advance, Jos Op 21-1-2020 om 11:00 schreef hugen@...: In NanoVNA-H4, you can modify the display format of the SIMTH chart through the menu "MARKER" ¡ú "SMITH VALUE". |
Re: Corrupted firmware.
I wanted to document a solution to this problem that I found on the Wilderness Labs website. I will quote their steps directly so that we have an archive of the STM32 BOOTLOADER driver issue:
1) Connect your device in bootloader mode. 2) Open Device Manager 3) Find Universal Serial Bus devices > STM32 BOOTLOADER 4) Right-click STM32 BOOTLOADER and select Uninstall Device 5) In the Uninstall Device window, check Delete the driver software for this device, and click Uninstall 6) After uninstall is complete, the device will appear as STM Device in DFU mode under Universal Serial Bus controllers. 7) Reconnect the device in bootloader mode. These instructions and photo came (with permission) from the following web page: 73, Brian |
Re: SMITH CHART REACTANCE LINES.
On Wed, Jan 22, 2020 at 08:54 PM, hwalker wrote:
.... (and probably most casualMaybe, but I 'm not sure. However, thank you for your answer. As for me, I would be absolutely happy if this little line R+/-jX appeared on the NanoVNA-H screen. ))) 73! |
Re: SMITH CHART REACTANCE LINES.
On Wed, Jan 22, 2020 at 09:19 AM, Andy UA3RAW wrote:
Oristo wrote: I very much appreciate being able to select my 10kHz - 1 MHz stimulus calibration and e.g. check components or capacitance of short cables on the Smith chart display So am I. ))) But what is the problem to display an additional line with R+/-jX as on NanoVNA-Q screen on the screenshot below. Maybe because of memory limit? ============================================================ Andy, For designing matching networks I also prefer the R+/-jX format but the majority of the time, as commented by Oristo , I (and probably most casual users), use the NanoVNA-H to check components and sweep networks. Fortunately, whatever your preference, there is a firmware version out there that meets it (see message #9989). You are correct that because of flash memory space each firmware designer has to pick and choose what features they include. The NanoVNA-H4 has twice the flash memory of a NanoVNA-H and should be future proofed from this limitation for a while. A while should be translated as until every additional feature under the sun is added. - Herb - Herb |