Re: 2 poles filters teminaison impedance
Roger, You are correct that it does not change the actual impedance presented to the filter. However, it is possible to mathematically compute S parameters in, say, a 500 ohm system knowing the S
By
John Gord
·
#29661
·
|
Re: 2 poles filters teminaison impedance
Edy555, the first NanoVNA developer, did some measurements on monolithic crystal filters like the ones Gerard is using (45R15AZ; motorola 20J26) . The article is on his website in Japanese at the link
By
Roger Need
·
#29660
·
|
Re: 2 poles filters teminaison impedance
I respectfully disagree with you. The Port Z feature in the latest DiSlord software only does the mathematical calculations necessary to convert the measurements to a different system impedance (like
By
Roger Need
·
#29659
·
|
Re: 2 poles filters teminaison impedance
Gerard, 1) The DisLord firmware should work on most any NanoVNA, clone or not. 2) I don't know if the PORT-Z feature works via NanoVNASaver. 3) 3-leged filters should work with the PORT-Z method.
By
John Gord
·
#29658
·
|
Re: 2 poles filters teminaison impedance
Hello John, Thank you for your response 1) First I have to see if I can download it into my nanoVNA (Compatibility) and study how to do it. See picture probably a clone 2) Then I emulate more with a
By
Gerard
·
#29657
·
|
Re: NanoVNA App - Installation and Use
#applications
Thanks for the tip. I got a new display and now the screen capture works. The old display has the version 1.0 and the new display has the version 1.1.
By
Klaus G?bel
·
#29656
·
|
Re: 2 poles filters teminaison impedance
Gerard, The latest DisLord firmware for the NanoVNA does allow you to see what the filter response would be with a load impedance different than 50 ohms. First perform an SOLT (short, open, load,
By
John Gord
·
#29655
·
|
2 poles filters teminaison impedance
Hello, How to find the values of the "Terminating impedance" of a filter 2 poles. (values of resistor and capacity) I have 2 models, but I can¡¯t find the values on the Net (45R15AZ; motorola 20J26)
By
Gerard
·
#29654
·
|
Re: #nanovna-saver I'm stuck
#nanovna-saver
Download link in this message >> /g/nanovna-users/message/29523 Roger
By
Roger Need
·
#29653
·
|
Re: #nanovna-saver I'm stuck
#nanovna-saver
Hi Francois ... As you told " ....I went from 0.3.8 which worked under Seven ..." , friend of yours, gave you a "special" version 0.3.10 which, according to your experience, works fine under WIN-7 ...
By
Peter
·
#29652
·
|
Re: #nanovna-saver I'm stuck
#nanovna-saver
Why don't you go back to an earlier version. What does not work is to use a recent version on an old OS. I don't think it affects the drivers (what do the experts say?). Personally I went from 0.3.8
By
F1AMM <18471@...>
·
#29651
·
|
Re: #nanovna-saver I'm stuck
#nanovna-saver
The first thing I would try is to use a new USB cable. They do wear out. And Saver, as good as it is, does not do very good error checking on returned data from the nano - it wxpects it to be
By
Stan Dye
·
#29650
·
|
Re: #nanovna-saver I'm stuck
#nanovna-saver
0.5.2 is buggy. Wait for 0.5.3 https://github.com/NanoVNA-Saver/nanovna-saver/issues/541#top I am testing fixes daily as the developers sort out the problems. (Linux here but I'm sure these issues
By
Barry Jackson
·
#29649
·
|
Re: #nanovna-saver I'm stuck
#nanovna-saver
Brent I just downloaded SAVER 0.5.2 and it is working fine with my Win10 (10 yr old) desktop. I do not see a whole lot of changes compared to earlier SAVER versions in terms of measuring common
By
Barry K3EUI
·
#29648
·
|
#nanovna-saver I'm stuck
#nanovna-saver
Tonight NanoVNA Saver started crashing a few seconds after I connect to the first gen NanoVNA I've been using for a long time. The program finds the serial port, and is stable until I connect. It says
By
Brent DeWitt
·
#29647
·
|
Re: Firmware Version?
According to information I found, the MS version will have a _M after the model number. Both my NanoVNA-H and NanoVNA-H4 do not have the _M after the model number so they are SI models. There is also
By
Brian Donaldson
·
#29646
·
|
Re: DiSlord v1.2.0 instability even though MS5351 clock-generator is selected (MS-3.6 HW version)
Tim and Dragan, Thanks for your inputs. I have now updated my H4 with the SI dfu file.
By
manor
·
#29645
·
|
Re: Firmware Version?
Several years old use SI version. MS version is for recent production units with MS on the back label. Roger
By
Roger Need
·
#29644
·
|
Re: Firmware Version?
/g/nanovna-users/message/29639
By
Dragan Milivojevic
·
#29643
·
|
Firmware Version?
I have a NanoVNA-H4 which is several years old. The back says HW version 4.2. The firmware lists contain either a "MS" or "SI". My 5351 says "BG008 006. Which version of firmware should I use? Thanks,
By
John N0TA <reillyjf@...>
·
#29642
·
|