¿ªÔÆÌåÓý

ctrl + shift + ? for shortcuts
© 2025 Groups.io
Date
Re: usb controled rf generator.
I have one.? I am happy with it, except that the USB connector is only soldered to the circuit board, rather than screwed to something solid.? I read somebody's report that the connector had come
By Jim Allyn - N7JA · #6073 ·
Problems on installation on Linux
Hi all, I'm installing the Linux version of nanovna-saver on a netbook with a 32-bit Debian 10.1 installed. I have installed all the required packages but when I give the command python3.7 -m pip
By ik0ozb@... · #6072 ·
Re: Success in automatic bridge and calibration error correction calculation #internals #calibration
Garry Thanks for the feedback. I tested also with a better semi rigid cable. The model finds a somewhat different R, I guess the cable has a bit different impedance but the imaginary part is the same.
By Erik Kaashoek · #6071 ·
Re: edelay vs ELECTRICAL DELAY and other fun #internals
To analyze possible confounding factors, modify: main.c cmd_vbat() - chprintf(chp, "%d mV\r\n", vbat); +/* needs adc_stop(ADC1); ?? */ +chprintf(chp, "%d %d\r\n", adc_vbat_read(ADC1),
By Oristo · #6070 ·
Re: Voltage sensing diode
No, this is TRACE 2 baseline marker :)
By QRP RX · #6069 ·
Re: Success in automatic bridge and calibration error correction calculation #internals #calibration
Hi Erik; I think your assumptions are incorrect. To achieve what you are attempting requires your test cable be free of imperfections. In truth, the cable is not likely precisely a constant Z0 equal
By Gary O'Neil · #6068 ·
Re: Success in automatic bridge and calibration error correction calculation #internals #calibration
Kurt suggested that very good cable is wanted, e.g. airline. I notice better results from LMR-400 than RG58 or RG316
By Oristo · #6067 ·
Success in automatic bridge and calibration error correction calculation #internals #calibration
After calibration with the correct calibration error parameters, a 1 meter cable connected to the reference plane with short and open at its other end, should give perfect circles spiraling inwards in
By Erik Kaashoek · #6066 ·
Re: a place to compare features?
QRP RX recently updated his README: https://github.com/qrp73/NanoVNA-Q/blob/master/README.md
By Oristo · #6065 ·
Re: NanoVNA does not want to start -solved
Bob, https://www.aliexpress.com/wholesale?catId=0&initiative_id=SB_20191030105308&SearchText=IP5303 But be careful - some vendors charge big $$ for shipping.
By Larry Rothman · #6064 ·
Re: NanoVNA does not want to start -solved
Where to buy IP5303?
By Bob Albert <bob91343@...> · #6063 ·
Re: Voltage sensing diode
Thanks for the image, KVR5 Your hand is steadier for soldering than mine.. @QRP - does the small red mark next to it signify bad hardware?
By Oristo · #6062 ·
Re: has anybody tested hf traps
That's exactly what I do at LC. "You can also connect trap to hot ends of both CH0 and CH1 and do S21 measure without need for coil adapter. It worked for me when I was unable to detach trap from
By Igor - PY3IG · #6061 ·
Re: NanoVNA questions
IF your reply DID NOT start with put-down I would reply....
By vaclav_sal <vaclav_sal@...> · #6060 ·
Re: NanoVNA questions
IF you would have looked in the Files and Wiki sections of the forum - all of your questions would have been answered except #1.There is no trademark - only a copyrighted name, owned by edy555. Check
By Larry Rothman · #6059 ·
Re: usb controled rf generator.
Sure, but one fixed LPF suffices, rather than LPF tracking swept square wave.
By Oristo · #6058 ·
NanoVNA questions
Before purchase I would like to have the following answered / verified Is ¡°NanoVNA¡± a trade mark? (verify) Is ¡°NanoVNA¡± open source ¨C both hardware and software ? (verify) ¡°NanoVNA ¡° is
By vaclav_sal <vaclav_sal@...> · #6057 ·
Re: CH0 LOGMAG and CH1 LOGMAG after CAL RESET (with no calibration)
connect it to CH0, leave CH1 open
By QRP RX · #6056 ·
Re: CH0 LOGMAG and CH1 LOGMAG after CAL RESET (with no calibration)
There is a testing of hardware, to make sure that it provides adequate measurements. With calibration enabled possible hardware issues will be hidden by calibration. This is why I asked for screenshot
By QRP RX · #6055 ·
Re: CH0 LOGMAG and CH1 LOGMAG after CAL RESET (with no calibration)
Do the same with load on CH0 and CH1