Re: Measure crystal motional parameters? Needs 1Hz frequency steps
Reference clock source frequency error easily compensate by software in firmware or with external program. i requested it.
By
pgc1682@...
·
#6021
·
|
Re: Remove plastic screen protector?
In the USA the Dollar Tree stores often have large screen protectors that are labeled for some device but may be adapted ...? kd4e
By
David KD4E <dcolburn@...>
·
#6020
·
|
Re: Dead?
So it seems that the IP5303 should be replaced.? I opened the unit and found it but don't know where to obtain a replacement part.? My usual sources have no listing of this.? The only data sheets I
By
Bob Albert <bob91343@...>
·
#6019
·
|
Re: Remove plastic screen protector?
So does anybody have a link to where to get screen protectors? I've just had to order a new screen for my NanoVna.
By
Terry VK5TM
·
#6018
·
|
Re: Dead?
/g/nanovna-users/topic/nanovna_does_not_want_to/32846852
By
QRP RX
·
#6017
·
|
Re: Remove plastic screen protector?
Raymond Domp Frank wrote: I have found that the best and most accurate pointing device to use with the Nano is the stylus from an old Panasonic Toughbook. That was a hardened laptop series that are
By
N9KDY
·
#6016
·
|
Re: Dead?
Where is this related topic?? I'm not too good with the seup here. Bob
By
Bob Albert <bob91343@...>
·
#6015
·
|
Re: Dead?
many peoples reported issues with IP5303 charge controller chip. You can find related topic here. It has some workaround for bad IP5303
By
QRP RX
·
#6014
·
|
Dead?
I went to use my unit today and it came on for only a few seconds and shut itself off. Sometimes it won't come on at all and other times just a few seconds. Any ideas?
By
Bob Albert <bob91343@...>
·
#6013
·
|
Re: Measure crystal motional parameters? Needs 1Hz frequency steps
There is one item that may have been overlooked. The frequency error of the reference source for the PLL is 0.5 ppm., as used in the VNA. At 70 MHz, that is a 35 Hz error. I did a 6 pole crystal
By
alan victor
·
#6012
·
|
Re: Measure crystal motional parameters? Needs 1Hz frequency steps
The software that comes with the AIM4170/4300 can automatically measure crystals.? I have designed about 20 different crystal filters? using this software and the results are virtually perfect with
By
Larry Benko
·
#6011
·
|
Re: Measure crystal motional parameters? Needs 1Hz frequency steps
Hi Alan Oristo just told QRP has the solution Kind regards Kurt -----Oprindelig meddelelse----- Fra: [email protected] <[email protected]> P? vegne af Alan G3XAQ Sendt: 29. oktober 2019
By
Kurt Poulsen
·
#6010
·
|
Re: Measure crystal motional parameters? Needs 1Hz frequency steps
Hi Alan Yes I missed that point and agree 1Hz step is a must. But I have seen mentioned in a posting frequency steps of 1Hz for a special firmware but when and from whom I do not recall Kind regards
By
Kurt Poulsen
·
#6009
·
|
Re: Measure crystal motional parameters? Needs 1Hz frequency steps
you can find firmware here: https://github.com/qrp73/NanoVNA-Q/releases Just tested 0.4.2 supports 1 Hz steps. Frequency steps smaller than 1 Hz is not supported, because frequency is represented with
By
QRP RX
·
#6008
·
|
Re: Remove plastic screen protector?
All the NanoVNA devices use resistive touchscreen devices so it is irrelevant if you leave it on or take it off. However, replacing it with a real screen protector is always a good idea.? ... Larry
By
Larry Rothman
·
#6007
·
|
Re: edelay vs ELECTRICAL DELAY and other fun
#internals
This is really a 2nd order polynomial...it seems to be entirely adequate. Higher order (x^3...) polynomials can be made to fit almost anything in a strict range, but IMO much above 3rd is not
By
Rich NE1EE
·
#6006
·
|
Re: edelay vs ELECTRICAL DELAY and other fun
#internals
More points means more long measurement and more high probability of some interference spike. I think may be there is need for a median filtering, but there is too small memory in order to do median
By
QRP RX
·
#6005
·
|
Re: Measure crystal motional parameters? Needs 1Hz frequency steps
yes, it supports 1 Hz step, also there is fixed frequency rounding error and it measure exactly these frequencies which are requested. With old firmware versions you will get random frequency errors
By
QRP RX
·
#6004
·
|
Re: Measure crystal motional parameters? Needs 1Hz frequency steps
At least QRP's recent firmwares accept 1Hz steps, e.g.: scan usage: scan {start(Hz)} {stop(Hz)} [points] scan 10000 10100 100 frequencies 10000 10001 10002 10003 ... 10098 10100
By
Oristo
·
#6003
·
|
Re: Remove plastic screen protector?
Different types of protectors exist for plastic screens: One is just meant to protect the plastic screen surface from scratches (and fingerprints) while being handled during manufacturing and
By
Raymond Domp Frank
·
#6002
·
|