All of my gear is in storage so I can't test ATM but if I
remember correctly, upon first connect it does not detect
the version string that it expects, so it newer runs the
get_running_frequencies function.
It usually prints out a message in the console, but I don't remember
what it was.
toggle quoted message
Show quoted text
On Sat, 17 Jul 2021 at 16:54, DiSlord <dislordlive@...> wrote:
If i correct understand problem in loaded from NanoVNA start/stop range?
NanoVNA Saver not correct do this if not detect VNA:
Here this code:
def _get_running_frequencies(self):
'''
If possible, read frequencies already runnung
if not return default values
Overwrite in specific HW
'''
return 27000000, 30000000
This function not defined for H4 ?:
def _get_running_frequencies(self):
if self.name == "NanoVNA":
logger.debug("Reading values: frequencies")
try:
frequencies = super().readValues("frequencies")
return frequencies[0], frequencies[-1]
except Exception as e:
logger.warning("%s reading frequencies", e)
logger.info("falling back to generic")
else:
logger.debug("Name %s, fallback to generic", self.name)
return VNA._get_running_frequencies(self)