On Thu, Feb 13, 2025, 1:07?PM чавдар левков via <lz1aq=[email protected]> wrote:
Hi Simon,
In coplanar loops the currents from A and B are simply added. So if B is noisy then A+B will be also noisy.
Yes, that's what I assumed as well, thank you for confirming that!
This cable layout is more important? if you use loops in dipole mode. In loop mode it almost does not have an impact.
Why loop B is more noisy? I do not know but in near field region every meter matters! The height of the loop above ground is not very important in an open field with no obstacles but in your case .....?.
Yes, lower loop B is definitely physically closer to the place where I have all the computers, screens, etc. Makes sense!