Reposted to make the subject more descriptive.
All my power nets are global in my flat hierarchy.
One of them is local to each sheet instance (individually fused).
How can I make it local, i.e. rename it (functionally) from
+5V
to
/SingleHub/+5V
/SingleHub1/+5V
¡
??
DRC ?thinks', they are not connected (see attached image).
Axel
<Bildschirmfoto 2022-07-07 um 17.34.14.png>
You need to use the 'Replicate Layout' plugin to duplicate a layout for identical hierarchical?sheets. You can layout just one copy, place the pivots for each other duplicate sheets then just use the plugin to duplicate?them.
You can get the plugin through the PCM, but anyway
There is no feature to keep them synchronised, honestly that isn't really that useful, it sounds like a fancy 'software inspired' feature but when you are designing production PCBs where every trace matters, having things change without you explicitly asking them to would be terrible. You can just rerun the plugin when you have updated the layout.?
Craig
On Sun, 26 Jun 2022, 18:16 Tony Casey, <
tony@...> wrote:
On Sun, 2022-06-26 at 17:43 +0200, Axel Rau wrote:
It seems, that the scripting console could help.
Any hints?
I've never had to use the scripting console. What have you tried to update the PCB after changing the schematic? Are you saying Tools > Update PCB from Schematic (F8) doesn't work?
If you were expecting it to behave like Eagle, it doesn't.
---
PGP-Key:?CDE74120 ?? ?computing @ chaos claudius
---
PGP-Key:?CDE74120 ?? ?computing @ chaos claudius