Re: Grid bias 3-500Z
I think you are over thinking this degassing issue? By adjusting the amount of bias diodes you can adjust the anode current.
By mike repinski · #41049 ·
Re: Grid bias 3-500Z
So I went to full voltage tests with the 2 tubes in place. With zero bias I measure · CW voltmeter 1700 V measures 236*8=1888 V intensity 175 mA; the tubes do not redden 298 W (2
By Fran?ois · #41048 ·
Re: Grid bias 3-500Z
Yeah mate. FIIK?. Pair of 3-500Z and the cap was 4700uF/50V. When the amp was keyed, the reed relay contact shorted the 15k resistor in series with the diodes. The idle current would take a full
By Alek Petkovic · #41047 ·
Re: Grid bias 3-500Z
Hello Please do not think that I am not interested in your relevant information. I have to integrate them and, often, I redo the experiments not to verify their validity but to adapt them to my
By Fran?ois · #41046 ·
Re: Grid bias 3-500Z
##? what tube were u using ?? ?This makes no sense at all.? The string of diodes and the parallel? cap are in the circuit at all times...and in series with the 50-100K? cutoff resistor.? We
By Jim VE7RF · #41045 ·
Re: Grid bias 3-500Z
Hi Jim. I tried a large value electrolytic across the bias string and every time I keyed up, the ZSAC would take a while to stabilise at the set level. When I stuck something like a 22uF in its place
By Alek Petkovic · #41044 ·
Re: Grid bias 3-500Z
Francois,? ?with zero bias on the L4B, using Eimac 3-500Z's ( MU=130)? the? idle current is 220-230 ma = 575w to 600 watts of idle power.... = blast furnace. If using Chinese 3-500Z's (
By Jim VE7RF · #41043 ·
Re: Grid bias 3-500Z
John and Alek, my friend just spoke to Tibi at OM Power the other day. ?He called to order some FU728 tubes. ?Tibi said to him that his supplier of tubes in China is making a design change inside
By Louis Parascondola · #41042 ·
Re: Grid bias 3-500Z
What should happen if I add the red components in the attached schematic. I have the impression that it would do the opposite of the desired effect, we would block the tube on a strong RF input. I
By Fran?ois · #41041 ·
Re: Grid bias 3-500Z
Yes. At 2.5kV plate volts, you probably don't need bias. At 3kV in the TL-922, you definitely want bias but as VK6JX mentioned, forward biased string of 6A10 diodes is a lot cheaper than a 50W zener
By Alek Petkovic · #41040 ·
Re: Grid bias 3-500Z
Hi Francois. In my experience, the 7.5V Zener provides a little bit of bias to limit the quiescent current of a pair of 3-500Zs running at around 3kV to 150mA. This is the requirement for Class
By John Sparkes · #41039 ·
Re: Grid bias 3-500Z
Hello Now that both of my 3-500Zs have been de-gassed, I have a new question. · In the L7 (Drake) the bias is at 0 volts · In the Kenwood TL-522 it is -7.5 V as shown in the
By Fran?ois · #41038 ·
Re: Drake L-7
1-2 hrs max...per tube. Alright. Then I'll do the second 3-500Z valve. Then I'll do the full voltage tests with the Drake's HT transformer -- F1AMM Fran?ois De la part de Jim VE7RF via
By Fran?ois · #41037 ·
Re: Drake L-7
1-2 hrs max...per tube.
By Jim VE7RF · #41036 ·
Re: Drake L-7
Hello Cooking the tubes. It was necessary to modify the tube polarization system. As shown previously, the HT power supply is floating relative to ground. This trick allows the cathode voltage
By Fran?ois · #41035 ·
Re: Ameritron AL-1500 Relay
I had a bad relay on my Al-811H and went this route. There’s a write up on DX World here: https://www.worldwidedx.com/threads/ameritron-al811-relay-headache-solved-my-way.265840/ I bought special
By Elijah · #41034 ·
Re: Ameritron AL-1500 Relay
The AL1500 relay is a typical 3pdt 12v relay. ?There is nothing magical about it. ?There are many relays that can be subsidized for it if the original cannot be found. ?With Ameritron going out of
By Louis Parascondola · #41033 ·
Re: Ameritron AL-1500 Relay
Try w8JI, CTR Engineering, he may have one. 73? Andy? K9ATX -- "Where the Old Soo crossed the
By DupyRail · #41032 ·
Ameritron AL-1500 Relay
The output relay in my Ameritron AL-1500 needs to be changed. I checked with MFJ since they are still selling some Ameritron replacement parts, but no luck.? From the user manual, this is "RLY1" and
By Riki, K7NJ · #41031 ·
SVHFS Conference 2025, Call for Papers & Presentations
Here's an update on the SVHFS 2025 Conference; Deadline for papers has been extended to March 17 Registration is open; details are in the attached file. Thanks, Robin Midgett K4IDC
By Robin Midgett · #41030 ·