L16-30 are 480v plugs.? L15-30 is what I run for any machines with less than 25 FLA.? Dave
toggle quoted message
Show quoted text
Aaron,?
Consider 12/4 SOOW from a strain-relieved terminal?hardwired/structurally secure box on the ceiling and drop toward floor, then end that with L16-30R twistlocks. Then the machines have L16-30P twistlocks and it works great for plugging?in , disconnecting
for safety, and flexibility when it's needed to move around the shop floor or make the drop happen in just the perfect spot, independent of the walls. That extra euro wire is not connected to anything, just 3 220v hots and the ground conductor. Also makes
it easier to swap machines around when all the plugs are compatible, wherever they are located.
On Mon, Jun 26, 2023 at 12:27?PM Aaron Inami <
ainami@...> wrote:
Hi all,
For those who have 3-phase Felder and Minimax equipment, what plugs/outlets are you using??? Does your equipment work fine with the L16-30P plugs and L15-30 outlets?? (those are 3 hot plus 1 ground conductors).?? Or does the Felder/Minimax equipment require
a 5-wire connection with both ground and neutral conductors?
-Aaron
--