开云体育

Imran: ?The 5T1 does not have a 208V setting, only 230V with the +/-10%. ?Yes, it will start but not run. ?The secondary voltages on the right side of 5T1 are low, 20V although in the 30V slot. ?Terry

On Jun 1, 2022, at 3:29 PM, imranindiana <imranindiana@...> wrote:

Terence,

Not sure what year is your machine but mine is from 2011. Because of some experiences, I can share some information that may be useful.

First, per the schematic the start function is built into the brake board. I have seen the brake board and it looks just the same as in my K975 (just higher current rating due to 7.53KW on dual51 vs 5.5KW on K975). I did have the brake board go out on K975 and it would not start at all. It also blinked a 2 digit code, which I think was 55 but I am not positive. Point being it would not turn the motor, your case seems different.

Now there are 2 transformers in the machine. It would make perfect sense that on 5T1 you would need to move the L1 connection to 208V tab so all voltages shown on secondary are correct. You should be able to verify these voltages as well.

<image0.jpeg>

This is the 2T1, responsible for the 24VAC. It does not have a 208V tab. This would indicate to me that the 24VAC circuit is tolerant of 208V input.

<image2.jpeg>

HTH.

Imran Malik

On Jun 1, 2022, at 2:49 PM, Terence via <terencewoolston@...> wrote:

?All:

I need HELP. I moved my 7.35kw Dual 51 from a shop with 240V to a shop condo with 208V (two legs from a 3 phase utility supply to a single phase panel). ?The Dual runs on a Phase Perfect Phase converter. ?The Dual worked fine in the old shop but will not run in the new...it starts up but when it hits full speed it shuts down.

I called Felder and they said to change the transformer tap to +10 to make up for the 208 to 230. ?This did nothing...same issue. ?Now the recommendation is to replace the brake board as this handles the task from start to run modes. ?I have no confidence in that analysis as it worked just fine with 240V supply. ?In any case, since I am in the middle of a multi piece furniture production I absolutely must have the Dual operational. ?I ordered the brake board but want trouble shooting advice from some of the electrical experts that know Felder and frequent the FOG.

Help!!

Best, Terry