Crestron Home with Unifi Cameras 9
I must apologize in advance is someone has already answered this question. I am trying to set up my first crestron home and I want to add in my Unifi Cameras. I have added a manual camera but when I go back out to the user interface, there are no cameras listed. Can someone give me a procedure for connecting my Crestron Home to my Unifi Cameras please?
Started by F David A Coker @ · Most recent @
Construct and Masters 2025 18
Hi All, I heard that it was announced that all new panels(UIs?) will only support HTML5/Construct. This of course pushes the deprecation of VTPro closer, which I expect of course. I'm assuming that they'll have to keep it around to support the TSR and GO app, which kinda sux to have two platforms to support all the UI devices - Anyone heard plans for this issue?? Also, they're supposed to be getting the MPO ported over to Construct by the end of the year for us resi guys... Can anyone illuminate more details on what they've heard about this? My concerns: - Construct needs to be solid - This forum has detailed much of the suffering over the last 2.5+ years. How are things going? Any light that we would be able to deliver real, client systems with it now/anytime soon? - We need the MPO - Ideally we need to have Construct support all the UI types TIA!
Started by ckangis @ · Most recent @
What is this Console Notice?? 5
Anyone know what this is/means?? 1. Notice: servicesd.exe # 2025-05-17 11:02:50 # CrestronMIB: Exceded 3200 It's from a Pro3 with the latest FW just updated. I got 500 of them with the same time-stamp...
Started by ckangis @ · Most recent @
Has anybody worked with Epiphan's Pearl2 rest API
Hello, I was wondering if anybody has worked with a pearl2 and used a TCP/IP client symbol with a SIO to send HTTP PUT commands to it to change outputs. I'm sure a Simpl sharp module is the way to go, but I lack the knowledge. Looks like it can be done without simpl# ,but I can't get the syntax right. I figured out the syntax for just doing it through windows command prompt, but anything I try through debugger and a SIO tells me to piss off basically. They have a module for it in application market, but it doesn't do a couple of things I would like it to. Thanks, Mike
Started by mike@... @
Rx to analog? 4
Hey guys, Basic topic for most of you, but how would you suggest I get the time elapsed/remaining Rx from my Denon DN-500BD MKII Blu Ray into an analog join displaying time format? I don't know SIMPL+, and guess that's probably the likely route, but any help is greatly appreciated. Dan
Started by dwiencek@... @ · Most recent @
Directv Control mystery + 3Path IR file - takeover job 3
It looks like I'm going to reprogram a restaurant/bar system with 20 sources and 57 TVs all because some of the source satellite boxes have been changed and they need updated IR drivers but the original programmer has supposedly lost the code - sigh. The system uses the Just Add Power AV over IP stuff I'm familiar with. But I did notice on my visit this morning that there are 8 of the small Directv boxes which only have satellite, HDMI out and power connected but these are all being controlled...somehow. I didn't find any DTV stuff on a network scan and nothing in the IP table. I should have also done a WHO command but forgot to in case there was any direct socket stuff going on that could explain it. But weirdly when I was connected looking at the files on the Pro3 hoping in vain to find the source code .zip file, I did see a .dll called something like DirectvShef. I know Shef refers to the old serial command set you could send through the USB. So really curious how they are achieving control. I thought it might have been CEC control from the Just Add Power encoders, but it doesn't look like they can do that. Any suggestions gratefully received. 9 Dish boxes were removed and in their place are now something called Roberts 3Path boxes. These are for sport content only. I am looking for an IR driver in case anyone has one. On site the remotes there are all bluetooth and paired to each individual box, but the boxes do have IR windows and an IR remote exists, but they don't have one on site. Thx in advance OP
Started by spannertech@... @ · Most recent @
TSR Performance issues 10
I have a site that is reporting TSR issues, pages/suppages slow to populate or not populating, sluggishness, etc. I was just told by my network guy that: "Crestron has identified an issue with the latest version of the firmware on the TSR-310's. It's not affecting all remotes, but it depends on the chipset you have. They recommend rolling back to one version previous to get it working properly again. " Currently using 'tsr-310_3.000.0010.puf' - Anyone heard about this and know if we're supposed to roll back to the .0186 version? Also, how would one determine the chipset used, etc. etc. And Crestron - Any possibility that we could have better communications??????
Started by ckangis @ · Most recent @
Shared Gateway 2
So I just tried to add a third IP table entry to my CEN-GWEXER thru TBx/System Info and found that It wouldn't let me. This begs the question: - How many entries are actually allowed? - How would a mere mortal find out info like that? I'm also wondering the same about the new CEN-GW1... Any ideas? I'm going to try adding thru console...
Started by ckangis @ · Most recent @
Lutron QSX/RA3/Leap Protocol and VLANs 2
I was interested/concerned about the issue of LEAP not being able to cross VLANs brought up in a different thread, so I thought it would be better to start a new one vs fork the other thread... As we have just revamped our network scheme to be multi-VLAN, I'm concerned about this issue. We don't generally deal with Lutron but we always get take-overs with them so we have to be agile... What are others' experiences with using QSX/Ra3 and the LEAP protocol with VLANs - specifically, Crestron on VLAN 1 and Lutron on VLAN 2 for example. I personally am only interested in Crestron custom apps since we don't use HOME... It's hard for me to imagine that with a pro network and someone who knows how to configure it that this would be a problem, but...you know...:)
Started by ckangis @ · Most recent @
newtonsoft question 5
Is there a way to not serialize a property in an object that is not initialized. Something like the [JsonIgnore] but I want to include the property if I set a value for it and leave it out of the serialization if it isn't set. For example, public class Account { public string FullName { get; set; } public string EmailAddress { get; set; } [Something like JsonIgnore] public string PasswordHash { get; set; } } Then Account account = new Account { FullName = "Joe User", EmailAddress = "joe@...", PasswordHash = "VHdlZXQgJ1F1aWNrc2lsdmVyJyB0byBASmFtZXNOSw==" }; string json = JsonConvert.SerializeObject(account); Console.WriteLine(json); // {"FullName":"Joe User","EmailAddress":"joe@...","PasswordHash":"VHdlZXQgJ1F1aWNrc2lsdmVyJyB0byBASmFtZXNOSw=="} However in the case where PsswordHash isn't initialized with a value Account account = new Account { FullName = "Joe User", EmailAddress = "joe@...", }; string json = JsonConvert.SerializeObject(account); Console.WriteLine(json); // {"FullName":"Joe User","EmailAddress":"joe@..."} So again, when PasswordHash isn't initialized it doesn't get included in the JSON at all. Thanks in advance for the help Jay
Started by jbasen @ · Most recent @
TSR Wifi performance - Ping Test
Hi All, We have a site where the TSRs are seemingly sluggish and sometimes won't populate SubPages (This is a custom system) Here's an example of some pings that are consistent with 3-4 TSRs of varying vintage, all with the latest v3.0.10 FW ping 10.32.101.94 Pinging Host 10.32.101.94 Reply from 10.32.101.94: Echo size=32 time=67ms TTL=63 Reply from 10.32.101.94: Echo size=32 time=3ms TTL=63 Reply from 10.32.101.94: Echo size=32 time=108ms TTL=63 Reply from 10.32.101.94: Echo size=32 time=25ms TTL=63 PRO3>ping 10.32.101.94 Pinging Host 10.32.101.94 Reply from 10.32.101.94: Echo size=32 time=99ms TTL=63 Reply from 10.32.101.94: Echo size=32 time=16ms TTL=63 Reply from 10.32.101.94: Echo size=32 time=35ms TTL=63 Reply from 10.32.101.94: Echo size=32 time=3ms TTL=63 Does this seem normal for Wifi TSRs? Hard-wired devices GW1, TSW, etc. ping out at 1-4ms consistently... TIA!
Started by ckangis @
Quotes are being added around a Serial String 7
I'm trying to use a Simpl# module "Crestron-WLED" that is getting quotes added around a serial string that aren't needed. https://github.com/mwohlert/Crestron-WLED I've tried to look in the module and I don't see where the quotes are being added. I'm not sure if this is a compile setting, simpl setting or a user error. I sent only brightness values 50. If you notice the "col":"" has "" and the serial string is empty. {"on":true,"bri":0,"transition":0,"seg":[{"col":"","bri":50,"fx":0,"sx":0,"ix":0}]} This string I sent had brightness value of 50 and color value of [[128,128,128]] but it gets sent as "col":"[[128,128,128]]" (I underlined the issue) {"on":true,"bri":0,"transition":0,"seg":[{"col":"[[128,128,128]]","bri":50,"fx":0,"sx":0,"ix":0}]} This is what the string should have been sent as. {"on":true,"bri":0,"transition":0,"seg":[{"col":[[128,128,128]],"bri":50,"fx":0,"sx":0,"ix":0}]} Any help figuring this out would be greatly appreciated. All Crestron software is updated, firmware on CP3N is latest version. If any other info is needed will be glad to provide it. Thanks Jason
Started by jaevans@... @ · Most recent @
Sony K55S30 Displays
Good afternoon. I am controlling these displays via RS232. Everything seems to be working as I would think with the exception of the "enter" button. We are using the built-in tuner for CATV. I can change the channel using channel up and down but putting in a channel number and hitting enter to change the channel, that is the part is not working.
Started by Rick Arnold @
Lutron RadioRA 3 Processor not connecting 15
Hello, I've been having issues getting my RA 3 proc to connect to my simpl windows program. I'm using the publicly available v1.1 modules on a DMPS3-4k-150c. My company does almost exclusively QSX and I've never run into this issue with those systems. I have set up an integration login in the ra3 processor and have triple checked the password. I am also able to ping the Lutron processor from the dmps. When I pulse connect, debugger shows LutronLeapCommLib1[ Connecting to: "PROCESSOR IP" ] and then nothing else. When I open the error log on the processor I see this error after program init: 50. Error: splusmanagerapp.exe [App 1] # 2025-05-10 20:28:14 # Module S-4.1:S-1 : Lutron_RadioRA_3_Command_Processor at line 141: Unhandled Exception: System.TypeLoadException: Method not found: m_fClientX509Cert Crestron.Infrastructure.ATcpClientSocket. at Crestron.SimplSharp.CrestronSockets.SecureTCPClient.Conn 51. Error: splusmanagerapp.exe [App 1] # 2025-05-10 20:28:14 # ectToServerAsync(SecureTCPClientConnectCallback pCallBackFunction) at Lutron.Leap.CommLib.CommandProcessor.Connect() at UserModule_LUTRON_RADIORA_3_COMMAND_PROCESSOR.UserModuleClass_LUTRON_RADIORA_3_COMMAND_PROCESSOR.CONNECT_OnPush_0(Object __Even 52. Error: splusmanagerapp.exe [App 1] # 2025-05-10 20:28:14 # tInfo__) at Amib.Threading.Internal.WorkItem.o() at Amib.Threading.Internal.WorkItem.Execute() at Amib.Threading.SmartThreadPool.e(WorkItem A_0) at Amib.Threading.SmartThreadPool.p() Anyone else seen this before/know how to fix?
Started by UnifiedChicken @ · Most recent @
NewtonSoft Problem 5
I'm trying to convert some JSON into a series of C# classes. My problem is that one of the classes is named Event and this is causing a conflict with SimplWindows because that name is already used. I know that NewtonSoft allows you to use JsonProperty to perform a renaming of an element of a class to avoid a similar conflict but I can't find anything that will solve this problem for a class. ERROR (LGSPLS1000) 'Event' already defined public class Root { public int id { get; set; } public string type { get; set; } public Event @event { get; set; } } public class Event { public string event_type { get; set; } public DateTime time_fired { get; set; } public string origin { get; set; } } Thanks in advance for the help Jay
Started by jbasen @ · Most recent @
Signal Change Events on the 4-Series 3
I'm going through the learning cliff of programming for a 4-series processor with VS2019. I always try to program my drivers using VS2008 so the code can be run on a 3-Series processor or a 4-Series processor. In this case I need VS2019's support for WebSockets. To pass data back to a group of Simpl+ modules I would do the following with VS2008: public class SerialChangeEventArgs : EventArgs { public string entity_id { get; set; } public SerialChangeEventArgs() { } public SerialChangeEventArgs(string entity_id) { this.entity_id = entity_id; } } public static class SignalChangeEvents { public static event SerialChangedEventHandler onSerialValueChange; public static void SerialValueChange(string entity_id) { SignalChangeEvents.onSerialValueChange(new SerialChangeEventArgs(entity_id)); } } However, under VS2019 I get the following error: Error CS0246 The type or namespace name 'SerialChangedEventHandler' could not be found (are you missing a using directive or an assembly reference?) I have the same "using" directives that I have used with VS2008. Any assistance would be greatly appreciated. Thanks Jay
Started by jbasen @ · Most recent @
VX automate / 1Beyond user feedback 8
Hi all, I'm looking for feedback from anyone with firsthand experience using the VX automated system. We're about to move forward with a 1Beyond/VX Automate system for a large conference room intended for upper management, and I¡¯d appreciate any insights you can share. Thx
Started by Anhtu Vu @ · Most recent @
Intelligent Video System 1 beyond v-sam-vxp- 1b 6
Hi guys so I have been trying to use the crestron automate vx solution. However I have been facing challenges especially in the tracking part and autoswitching. Is there anyone who has successfully deployed this system here and are willing to assist. 4 iv- camptz-12 and 4 iv-camptz-20 are the cameras being used.
Started by Heri Itika @ · Most recent @
POLY GY500 CONTROL VIA RS232 7
Hello team, I have a poly G7500 that is/was being controlled via rs232 by a CP4.This was working fine. However, this stopped recently. On COM port 1 of the CP4 I can no longer receive feedback from the poly G7500.When I change to COM port 2, I occasionally get feedback from the G7500, however seems to be just to be random symbols. Kindly advise.
Started by Heri Itika @ · Most recent @
TSW-770 Virtual Buttons on XPanel 3
Hi all, thanks for taking the time to read. I would like to know if there is a way to show the Virtual Buttons tool bar in XPanel, I was tasked to update a system from an old TSW 1050s series that has Hard Buttons programmed (Power ON/OFF, Volume UP/DOWN, Light Presets). I know this new 70 series panels have those buttons on a tool bar, but when I Saved As my VT project as TSW 770 and I run the XPanel I don't get to see those buttons. There is any way to make XPanel to show the Virtual Tool Bar on a 70 series like it would show Faceplate on 50 or 60 series ? Thanks !
Started by santiago@... @ · Most recent @