I believe the main fusion module starts at 50.? There is no standard for what signals get used and an order, you need to come up with one for the site deployment that you use.
The official training, newer method, is to use all the SSI modules to do this type of thing, and any type of equipment info you want to pass connects into it's own equipment or display module, or extension module that all connect to the main Fusion symbol.? When you use this newer (more flexible) method, the main Fusion symbol gets connected to a main SSI module, and then all the auxilliary monitoring modules tie in to the main SSI module.? This keeps everything kind of segregated.? It also allows for auto-detection to work when you discover rooms in Fusion better.
Sometimes this new method feels like overkill, but it really does kinda make it better since you can easily get signal conflicts between rooms using the old method.
--