¿ªÔÆÌåÓý

ctrl + shift + ? for shortcuts
© 2025 Groups.io
Date

Re: Changing the RFID on an HR150

Yves Delaune
 

Hi Jay.

connect the HR-150 via USB to your computer and use Toolbox to change the ID

Best regards


On Monday, February 15, 2016 8:55 PM, "Jay Gilliatt jaygilliatt@... [Crestron]" wrote:


?
Just aquired an HR-150 to an ex gateway and it shows up at 01. I need it to be 03
Can anyone please tell me how this is done.
It only comes with a basic manual.

Many thanks
Jay



Re: Sky Italia Ir Code

 

I do. I'll upload it tomorrow morning UK time for you.

I remember this giving me a headache first time around. I don't wish that upon anyone else!


Re: Basic Sonos controls

 

Lode for Sonos works very very well:


Re: Basic Sonos controls

 

Are you referring to this one by Cresmods.com? Yes only 3-series and not tested with more than 3 players.

?


Re: Yamaha YSP-5100

 

Do you get the config data packet back when you send the ready command?


Re: Yamaha YSP-5100

 

I did one of those about 5 years ago and I'm pretty sure I had to send that before any comms worked.
I went through similar pain as your are back then.

Looking back through my notes from then I used 9600,8,1,N and hardware RTS/CTS handshaking set on the comm port device settings dialog.


Re: Mobotix T25 -> Doorbell Trigger

 

If you read through the entire thread, Kevin Hawkins' reply on 3/29/14 describes the solution.

I did a system with one of these a couple of years ago, that also required a "doorbell" trigger. Someone else setup the "IP Notify" option in the Mobotix camera, but in the Crestron program I added a TCP/IP Server symbol for port 8003, then connected its Rx$ output to an SIO to match whatever string(s) they defined.

--- On Thursday, February 25, 2016 at 12:19 AM, steveita wrote:

Hi guys, i am very interested in this also. Has this been implemented?
Thanks


Re: HAI/Leviton security interface issue

 

No, HAI hasn't changed their RS-232 protocol. Most likely, the panel has "locked-out" the serial port, after five invalid log-in attempts (with wrong PC Access code).

To resolve it, make sure you have the correct PC Access code in the Crestron program, then power down both the HAI panel and the Crestron processor. Wait about 45 seconds then power-up the HAI panel first, wait another 30 seconds then power-up the Crestron processor. All should be good after that, assuming there are no other issues (which there shouldn't be, since it was working before the swap).

--- On Thursday, February 25, 2016 at 7:40 AM, Steve wrote:

A client recently had his HAI Omni Pro security panel replaced after a
lightning strike took it out. Even after changing the PC access code to
the value set by the installer, the Crestron RS232 interface cannot log
into the security. I am communicating to the HAI panel but when the Log
in command is sent to the panel, the panel reports back an negative
acknowledge meaning an invalid pc access code. Does any one know if
HAI/Leviton changed their protocol?


TSW-1052 Subpagefor the thermostat CHV-TSTAT not clearing

 

Hello Folks,


I am trying to understand why does every time that I wake up the touch panel or if I upload a project into the MC3 when the touch panel comes back online the sub-page of the thermostat to increase and decrease the temperature shows up on the screen by itself.


Thank you


Re: How to VPN into a Crestron Processor with DIR-880L router

 

Can anybody out there help me? Thank you


Re: Compile crashing

 

Hah!

On Thu, Feb 25, 2016 at 9:30 AM, cfm@... [Crestron] <Crestron@...> wrote:
?

"In my case, I have a KeyProA.usp which conflicted with KeyProA.csp."

Anyone else hear an echo in here?

? - Chip



Re: Compile crashing

 

"In my case, I have a KeyProA.usp which conflicted with KeyProA.csp."

Anyone else hear an echo in here?

? - Chip


HAI/Leviton security interface issue

 

A client recently had his HAI Omni Pro security panel replaced after a lightning strike took it out.? Even after changing the PC access code to the value set by the installer, the Crestron RS232? interface cannot log into the security.? I am communicating to the HAI panel but when the Log in command is sent to the panel, the panel reports back an negative acknowledge meaning an invalid pc access code.? Does any one know if HAI/Leviton changed their protocol?


New file uploaded to Crestron

 

Hello,


This email message is a notification to let you know that
a file has been uploaded to the Files area of the Crestron
group.


File : /Documents/Samsung Panel Setup Crestron Roomview_v2.pdf
Uploaded by : guestron <guestron@...>
Description : Samsung LED Panel - Roomview Control


You can access this file at the URL:



To learn more about file sharing for your group, please visit:



Regards,


guestron <guestron@...>


Sky Italia Ir Code

 

Does anyone have a update Sky Italia HD+ ir module which works. As in TV guide/Box Office etc etc and the MY sky?


Only code Ive been able to find on the net is TV guide, but am unable to learn the other via toolbox

?


Re: Yamaha YSP-5100

 

I tried the reporting command if that's what that is... it looks similar. What does that enable? Does nothing work until you send that command or is that just to enable feedback reporting?

I would have thought, from looking at the manual, that things like the power on/off/toggle commands should work regardless no?

Mike Jobson
Director
?


UX Digital Systems Limited
Approved Crestron Services Provider

?
Email: ?mike@...
Mobile: ?+44 (0) 7875 020894
Address: 16 Grassingham End, Chalfont St Peter, Gerrards Cross, Bucks SL9 0BP

UX Digital Systems Limited?is a limited company registered in England and Wales??| ?Company?Registration No.?09938561
Registered?Office:?Berkhamsted House,?121 High Street, Berkhamsted, Herts HP4 2DJ

This message is intended for the addressee only and may contain private and confidential information or material which may be privileged. If this message has come to you in error you must delete it immediately and should not copy it or show it to any other person.


On 24 February 2016 at 21:41, slip.cougan@... [Crestron] <Crestron@...> wrote:
?

RTS/CTS are crossover

RX/TX are crossover

Did you send the magic start command?
\x11\x30\x31\x32\x03




Re: Mobotix T25 -> Doorbell Trigger

 

Hi guys, i am very interested in this also. Has this been implemented?
Thanks


Re: (OT) Door lock suggestions.

 

¿ªÔÆÌåÓý

An electronic leverset is a necessity at my house.? My wife and I are out mountain biking, skiing, etc and don't want to risk losing our keys and locking ourselves out of the house.? Living in a resort town we also have frequent guests and need an easy way for them to come and go.

I've now had 3 electronic door locks at my house.? First a simple push button combo lock.? When Crestron added the Leviton Z Wave controller integration I replaced that lock with a supported Z-Wave Lock.? Finally I replaced the Z-Wave lock with the Crestron Yale lock.? The first push button lock worked fine but didn't offer any integration.? The Z-Wave system was a kludge.? It worked fine as a standalone lock but the integration was on the flakey side. ? The Crestron Yale lock is more that worth the price of admission.

Jay

On 2/24/2016 8:19 PM, Lincoln King-Cliby lincoln@... [Crestron] wrote:

?

+1

?

Not to mention the frustration and waste of money when you eventually change your mind anyway.

?

And this is coming from someone who is beyond uber cheap ¨C my house is the ultimate in ¡°odd¡± solutions¡­ But I have one of the Crestron/Yale deadbolts and one of the Crestron/Yale lever sets and I¡¯ve never looked back.

?

--

Lincoln King-Cliby, CTS, DMC-E-4K/T/D

Commercial Market Director

Sr. Systems Architect | Crestron Certified Master Programmer (Gold)

ControlWorks Consulting, LLC

Crestron Services Provider | Biamp Audia Certified | Extron Control Professional

?

From: Crestron@... [mailto:Crestron@...]
Sent: Wednesday, February 24, 2016 9:04 PM
To: Crestron@...
Subject: [Crestron] Re: (OT) Door lock suggestions.

?



Buy the one from Crestron. They integrate so easily. The time suck of a different one could easily eat up the extra cash.?




Re: (OT) Door lock suggestions.

 

¿ªÔÆÌåÓý

+1

?

Not to mention the frustration and waste of money when you eventually change your mind anyway.

?

And this is coming from someone who is beyond uber cheap ¨C my house is the ultimate in ¡°odd¡± solutions¡­ But I have one of the Crestron/Yale deadbolts and one of the Crestron/Yale lever sets and I¡¯ve never looked back.

?

--

Lincoln King-Cliby, CTS, DMC-E-4K/T/D

Commercial Market Director

Sr. Systems Architect | Crestron Certified Master Programmer (Gold)

ControlWorks Consulting, LLC

Crestron Services Provider | Biamp Audia Certified | Extron Control Professional

?

From: Crestron@... [mailto:Crestron@...]
Sent: Wednesday, February 24, 2016 9:04 PM
To: Crestron@...
Subject: [Crestron] Re: (OT) Door lock suggestions.

?



Buy the one from Crestron. They integrate so easily. The time suck of a different one could easily eat up the extra cash.?



Re: DMX interface?

 

I agree, just put one in and works for what i needed.