Re: CP3/CP3N Requires Reboot
On Fri, Jan 15, 2021 at 08:55 AM, @johnmax wrote:
Those Data aborts must be whats causing your issue. Run SPLUSTASKS and look for a Thread ID that matches one in your Exception Data Abort errors- in your case Thread-Id=09e60146. You will need to run it before the program resets as the Thread ID will change when the program restarts. When you find a Thread ID from the exception that matches one in SPLUSTASKS it will show you a module location in your program- that is the module causing the data aborts and probably your issues.?But the strange thing is the processor throws the "Data Abort" error along with the thread ID when I try to find it by using the SPLUSTASKS?command I am not getting that? Data Abort's thread ID so that I can pinpoint the SIMPL+ module even before the program restarts. I there something I am missing ??? Please let me know |
Re: Hidden causes of splusmanagerapp.exe exception Data Abort in simpl program.
#s
Even I am facing the similar issue "Data Abort" , But the strange thing is the processor throws the "Data Abort" error along with the thread ID when I try to find it by using the SPLUSTASKS?command I am not getting that??"Data Abort" thread ID even before the program restarts.
I there something I am missing ??? Please let me know |
Autonomic Coverart Issue
I currently have an Autonomic MMS-1e.? Recently I noticed that the coverart isn't displaying on my TPS-6L.? It used to work fine but now shows a spinning loading wheel.? The strange thing is that the coverart works fine on my Xpanel so it is something specific related to the 6L but I haven't changed anything with the programming.? I use the default program from the Autonomic website.? I know the 6L is old so I'm wondering if it is a cache storage issue or something similar.? Does anybody know how I would go into diagnosing the problem? Thanks. |
Re: CP3 Ethernet Issues
开云体育Ethernet watchdog is virtually always a network issue, specifically broadcast/multicast storms. Do you have AVoIP devices (e.g. NVX, Dante, etc. on the same VLAN)? If so make very sure that IGMP, etc. is properly configured on all switches. ? If I recall correctly the dwRxPacketReceived values indicate that it’s receiving more than 4400 packets per second which is not typical. ? If you fire up wireshark on a hardwired connection on the same VLAN it should be largely quiescent – some ARPing and other housekeeping traffic at? trickle – if you are seeing a constant stream from one or more IPs/MACs, there’s hard evidence of the problem I’m describing. ? -- Lincoln King-Cliby, CTS, DMC-E-4K/T/D ? From: [email protected] [mailto:[email protected]]
On Behalf Of Sharan Suvarna via groups.io
Sent: Sunday, January 17, 2021 5:38 AM To: [email protected] Subject: Re: [crestron] CP3 Ethernet Issues ? Hi Guys, FECTimer: Exceeded Receive Packet Trip Count, dwRxPacketReceived: 4408 in 1000 milliseconds FECTimer: Ethernet disabled by watchdog FECTimer: ETH RX re-enabled by watchdog It would be great If anyone could help me out in this issue. |
Re: CP3 Ethernet Issues
Hi Guys,
Even I facing the same issue in couple of places, the CP3 errlogs is flooded with watchdog errors. I don't know how to resolve this. When I asked help? from the crestron true blue support they just say its the network issue, the network is getting flooded with traffic. I don't think that's the case because the sane issue cannot be happening in all my clients place at the same time. FECTimer: Exceeded Receive Packet Trip Count, dwRxPacketReceived: 4408 in 1000 milliseconds
FECTimer: Ethernet disabled by watchdog
FECTimer: ETH RX re-enabled by watchdog
It would be great If anyone could help me out in this issue. |
Processors Losing IP table
I've had a rash of processors losing the IP table on a power cycle of the processor in the last couple of months. It's mainly been dmps 250/350's with firmwares 1.08.016 & 2.01.052 and cp3n's with 1.601.0050 & 1.603.0113. I tried the newest firmwares because that's TB response for everything and I've still encountered the issue.?
Anyone else having this issue or know of a resolution? Thanks. |
Re: Sonos AMP Discrete ARC Access
Yeah I was pretty excited when I tripped over that single IR code. We were in the middle of a pretty large Sonos install when the customer wanted to add local TV sound to a few rooms...it really saved my ass. Nice thing is it works every single time. Ive even been using IR for volume control lately and only relying on the volatile Crestron module for FB and basic control. This way ensures than WHEN the module fails the customer can still watch TV and control the volume.
|
Re: Sony UBP-X1100ES Power-On issue
开云体育I?m using WOL successfully on other devices, so i don?t think i?m doing something wrong. I?ve also tried a WOL-tool on my PC which I use for testing – that also doesn?t work reliable. And i?ve found some other posts on the internet mention that WOL only works once after a power-cycle. So there seems to be something. If it?s working 100% with you, i?d really interested how. I?ve now installed IR as a fallback just for powering up the player, but it would be nice if it would work completely via LAN. In this installation the player is sitting right below the processor so cabling is not an issue, but there can be other projects where this is not the case. ? Cheers, Thorsten ? Von: [email protected] <[email protected]> Im Auftrag von rickwookie ? Ok well I think I’m using the UDP client directly to do the WOL and it works. I’ll have a look later and post an update. |
Re: Sony UBP-X1100ES Power-On issue
开云体育I?m using a WOL symbol provided by TB. It works sometimes (so I guess it?s doing the right thing), but not always… ? The HDMI setting I mentioned in my previous mail didn?t help… I?ll probably send ?the power-on command via IR – the X1100 has a IR-plug on the back so that?s not a real issue. ? ? Von: [email protected] <[email protected]> Im Auftrag von rickwookie ? Only works via WOL for me (UK version of the player). Perhaps you’re doing the WOL wrong. How are you doing it? |
Re: Sony UBP-X1100ES Power-On issue
开云体育Hm, it seems as if setting “HDMI control” to “off” is required. ? ? Von: [email protected] <[email protected]> Im Auftrag von Thorsten K?hler ? Hi, ? i?m using the module from the group archive to drive this player to control it via IP. Everything works fine, including power-off. The only thing that doesn?t work is power-on. I?ve tried via the module and also via WOL. Player?s networking settings are allowed to be controlled via external control system. ? Am i?m missing something? ? Cheers, Thorsten |
Sony UBP-X1100ES Power-On issue
开云体育Hi, ? i?m using the module from the group archive to drive this player to control it via IP. Everything works fine, including power-off. The only thing that doesn?t work is power-on. I?ve tried via the module and also via WOL. Player?s networking settings are allowed to be controlled via external control system. ? Am i?m missing something? ? Cheers, Thorsten |
Re: VT - PRO e
I got this too this week.? I had the project open for a few days.? Closed it, and rebooted my laptop, and windows did an update and then all projects opened and would not show UI.? To fix, you ONLY need to update the new VTPro-e application itself.? I did not update anything else, including SG or databases of any kind.? The problem is corrected by VTPro-e update only.
-- Jason Mussetter Control Systems Designer Mussetter Programming Services |
Re: Curl formatting
Why are you sending it with any line breaks in a serial send? That's more for human readability, but in a send symbol it all appears on one line with your escape codes anyways meaning there is no added benefit in doing so... Minimize that JSON into a single line with no line-breaks or spaces.
{"device":"AA:AA:AA:AA:AA:AA:AA:AA","model":"H6141","cmd":{"name":"turn","value":"on"}} -- ?
Crestron Service Provider - TBD Enterprises Inc.
|
SIP Intercom
HI;
I am being asked to specify SIP intercom for a large-ish installation: ? 6 – TS-1542 15 – TS-1070 And replacing a Panasonic telephone system that has 30-ish extensions as well as a car-gate and man-gate.??Apparently they never actually use phone system for outgoing calls but only for intercom purposes.??Limited initiation of point to point calls, mostly an all-page kind of thing. ? Client seemed OK with using 770 or 1070 for replacement of Panasonic phones. ?A bit expensive, but I they also get the ability to see their 90-ish cameras, run HVAC, etc. so there is a bit of extra value there I guess. ? I have looked at demo program and understand phone book, etc.??but I would like to know if there is any additional hardware I will need to specify to support the number of endpoints. ? Also, I am wondering about the gate stations.??Drive up has an old skool DoorKing calling the Panasonic.???Is there any way to recognize an incoming SIP call from the gate, either via an appliance like Barix,?replacement?call box that has SIP, or whatever (i.e. not a touch panel) to trigger control system events? ?Can I get something at the gate to initiate all-call to 50 endpoints? ? ? |