Keyboard Shortcuts
ctrl + shift + ? :
Show all keyboard shortcuts
ctrl + g :
Navigate to a group
ctrl + shift + f :
Find
ctrl + / :
Quick actions
esc to dismiss
Likes
- Crestron
- Messages
Search
Sonos 3.1.0: IP Port Number Parameter Value?
Hi,
Latest Crestron Sonos Device Module 3.1.0 has parameter field for IP Port Number. I have three Sonos Ports gouing in. What should this value be for each of the three Ports? (No detailed help in the Crestron help file: "
Thanks in advance |
|
Re: MC3 Image
This is a common problem on PMC3 and MC3, i try it once and didn work, maybe i didnt copy it correclty,may i have a copy of the Image file,,,, pretty please?. i wish crestorn would use a better SD card so we dont have this problem, i am afraid to change programs, the more you write the faster it will degrade and die. We have sent easly around 6 of those to NJ to have the SD replaced, pain in the butt for the client to be 2 to 3 weeks with no lights or av processor, all this for a 20$ memory card
|
|
Lutron Radio Ra 2 over IP no feedback
#lighting
Hello,I am controlling a radio ra 2 over IP like i have done a million times but on this project i am able to contorl the keypads but there is no feedback on the buttons, i also notice that on the IP Table shows wating... online... not connected, constantly. i swtich over to 232 and works ok, have anyone experience this issue? rebooting both didnt help either. TIA
|
|
Re: CrestronXPanel Installer error
I had this the other day for the first time and wound up installing Adobe AIR from then running the CrestronXPanel installer.air package with no issues. On Mon, Jul 13, 2020 at 3:54 AM rockyoucvs <cvs@...> wrote: Thank you for this information, |
|
Re: CrestronXPanel Installer error
Thank you for this information,
Now I get below error : The application cannot be installed due to a certificate problem.? The certificate does not match the installed application certificate, does not support application upgrades, or is invalid.? Please contact the application author. Guess I'll need to update to latest sw versions, Thanks Best regards Chris |
|
Re: crestron app had an update today...
#crestronapp
Michael LaFayette
This is just insane.? I just wasted several hours literally tracking down an iPad just so I can debug these issues.
I've been told that it's being sort of dealt with on the Crestron side of things, but come on man.? Be better Crestron. |
|
Re: SIMPL Windows - Incompatible Signal Type when commenting out signal using "//"
Yes, it¡¯s the 3.0 version of the Biamp Tesira VoIP controls.?
|
|
Re: SIMPL Windows - Incompatible Signal Type when commenting out signal using "//"
Andrew Davis
Is it a Simpl module? There is probably a symbol inside with an ambiguous input (Could accept serial or analog).? You could create a dummy signal and use the force analog or any symbol that explicitly uses an analog join as an output.? On Sun, Jul 12, 2020 at 1:29 PM Mike Taylor <miketeachesclass@...> wrote: I'm encountering something weird - if I try to complete a symbol using ctrl+i, I'm getting the message |
|
SIMPL Windows - Incompatible Signal Type when commenting out signal using "//"
I'm encountering something weird - if I try to complete a symbol using ctrl+i, I'm getting the message
"Please note there are still incomplete items that SIMPL Windows did not have enough information to be able to complete.? ?As such this data must be completed manually.? Typically this is due to parameters that do not have default values defined".?? The unused DIgitals and serials have "//" on them, as expected.? The analogs don't. If I manually add "//" to an analog to complete the signal, the following error occurs: "Invalid Signal name or incompatible signal types.? Cannot connect to this signal here".?? I've not see this happen before; any ideas?? This is preventing me from compiling and loading, obviously, because the symbols aren't complete. If I delete all other symbols from the program, this symbol does complete properly.? Obviously this isn't a real fix, but just additional information. Thank you, MIke |
|
Re: Crestron app no longer available for IOS
#app
toggle quoted message
Show quoted text
On Sat, Jul 11, 2020, 4:28 PM <OSCAR7EMAIL@...> wrote: Have you guys realize the crestron app was taken down on the apple app platform? Is still available on Android market place? |
|
Crestron app no longer available for IOS
#app
Have you guys realize the crestron app was taken down on the apple app platform? Is still available on Android market place?
|
|
Re: crestron app had an update today...
#crestronapp
Michael S Moran
¿ªÔÆÌåÓýThere appear to be issues with the App and it has been temporarily removed from the App Store. ? From: [email protected] <[email protected]> On Behalf Of oleg_crestron via groups.io
Sent: Saturday, July 11, 2020 11:54 AM To: [email protected] Subject: Re: [crestron] crestron app had an update today... #crestronapp ? Just got a complain from client that Crestron app disappeared from his iPad. |
|
Re: Compiling Error Cisco SX80 V1.4 Crestron Module
¿ªÔÆÌåÓý
There is some funkiness happening with Cisco lately. Usually, I re-import archive the module, re-sync my database, and then recompile the code. But I've heard that the latest database is wreaking havoc with Cisco. I've always used the Cisco 2.3.9 module. What
Cisco module are you using?
Christian Arboleda, CTS
Mobile: (347) 880-2047
From: [email protected] <[email protected]> on behalf of Jacob Dobbs <jacob.m.dobbs@...>
Sent: Friday, July 10, 2020 7:39:27 PM To: [email protected] <[email protected]> Subject: Re: [crestron] Compiling Error Cisco SX80 V1.4 Crestron Module ?
I can confirm rolling back to Simpl v4.11 will fix this, had same issue.
On Fri, Jul 10, 2020, 5:37 PM DH <dhollander@...> wrote:
If you aren't compiling for 4-Series use SIMPL v4.11 instead of v4.14 to resolve SIMPL# compile issues with Cisco modules. |
|
Re: Compiling Error Cisco SX80 V1.4 Crestron Module
Jacob Dobbs
I can confirm rolling back to Simpl v4.11 will fix this, had same issue. On Fri, Jul 10, 2020, 5:37 PM DH <dhollander@...> wrote: If you aren't compiling for 4-Series use SIMPL v4.11 instead of v4.14 to resolve SIMPL# compile issues with Cisco modules. |
|
to navigate to use esc to dismiss