Keyboard Shortcuts
Likes
- Crestron
- Messages
Search
Re: Custom Animated Objects
Any chance you wanna make a YouTube video of this process? :)
toggle quoted message
Show quoted text
|
Re: Latest version of Samsung EXlink protocol
One-way serial. ?The issue is one way serial port goes between 0 and 5 volts as opposed to the ¡°full¡± com ports which go between -13 and + 13 volts. ?Some devices prefer the ¡°TTL version" of rs-232. From: <Crestron@...> on behalf of "floyd1212@... [Crestron]" <Crestron@...> Reply-To: <Crestron@...> Date: Thursday, January 19, 2017 at 9:19 AM To: <Crestron@...> Subject: [Crestron] Re: Latest version of Samsung EXlink protocol ?
Phil, |
Re: Sharp Serial Port
Always send the RSPW 1 when the TV is on. ?I send it 1 second before power off every time. From: <Crestron@...> on behalf of "rickmcneely@... [Crestron]" <Crestron@...> Reply-To: <Crestron@...> Date: Wednesday, January 18, 2017 at 11:41 AM To: <Crestron@...> Subject: [Crestron] Re: Sharp Serial Port ?
I believe that (in most cases) the RSPW1 command must be sent when the display is already on. |
Re: Sony Bravia tv controls
Go into the TV menu and find SimpleIP and turn it on, even if you are only using rs-232. From: <Crestron@...> on behalf of "mingomaster@... [Crestron]" <Crestron@...> Reply-To: <Crestron@...> Date: Wednesday, January 18, 2017 at 6:20 PM To: <Crestron@...> Subject: [Crestron] Sony Bravia tv controls ?
Has anyone experienced loosing controls on tv power on when tv is left off for more than an hour ? And the only way to get it back working is to turn tv with tv remote its self |
Re: Power Toggle logic
It's not possible to get this working in all cases.? You have three options: 1) get power feedback from the display somehow (current sensor, light sensor, USB power detect, EDID detect), 2) use a different display with discrete power commands, or 3) put a power toggle button on the touchpanel and manage user expectations (not ideal). On Thu, Jan 19, 2017 at 6:25 AM, jaime.short@... [Crestron] <Crestron@...> wrote:
|
Re: Adding a stop command after PZT action controlling a camera
"Or put your DPAD signals (up, down, left, right) into a NOR and drive the STOP command from the output.
As long as the STOP logic is only edge triggered, there's no need for any additional pulse symbols." The anal retentive among us hate the idea that this means a pan stop, tilt stop and zoom stop commands are generated/fired out every time the program starts up - that's why we use the neg trigger on pulses instead.? :) ? - Chip |
Re: Polycom Soundstructure C series
Andrew Welker
There should be a sample program in the zip file you used. Look at that for reference I how things are hooked up. You'll probably mostly be using the basic in and out modules.
|
Power Toggle logic
So I have a TV that only has a power toggle. I have to correct logic ( I believe) to only execute the power command when sources are selected after the TV is on so it doesn't turn it back off, and I thought I had the off working as well until I realized it throws the off again with a whole house off and ends up turning the TV on if its off and vice verse if it's in the other state. What would be the best logic or symbols to use to get this to function correctly. I was thinking a truth table but is there a better way (easier)?
Thank you in advance for any input on this. |
Polycom Soundstructure C series
new here in Crestron programming, I am working on a project which includes Audio Conference, with VoIP interface, my processor is CP3 and it is controlling the DSP via RS-232. I downloaded the C-series module from crestron application market but I do not know which of those modules do I need to use, because there's a lot of modules inside the folder. TIA! |
Re: Sony Bravia tv controls
toggle quoted message
Show quoted text
On Jan 18, 2017, at 6:43 PM, wiredhometechnologies@... [Crestron] <Crestron@...> wrote:
|
Re: Sonos and Swamp
What we have always done is 1:1 sonos connects going through the SWAMP. When the zone is "Off" we instead switch to the SONOS and fix the volume on the SWAMP, This allows the client to have the full sonos experience separate from the "Crestron" experience . .even thought hey are still using the SWAMP as an amp . .albeit unbeknownst to them. . Now this is pre-60 series but I dont see how anything would change. GUI volume is disabled and only Sonos volume matters at that point.
|
Re: Sharp Serial Port
miketx
In the power setting make certain the following are set:
Setup - Quick Start On System Options - Power Control Off It is also always best to update firmware. Mike From: Crestron@... [mailto:Crestron@...] Sent: Wednesday, January 18, 2017 1:23 PM To: Crestron@... Subject: [Crestron] Re: Sharp Serial Port I have recently ran into the same issue where the panel will not respond after the display is powered down. did you get any resolution? [Non-text portions of this message have been removed] |