Re: Pentair Screenlogic
I do know that the interface is a serial brick and that the software was deveolped by a company called Homelogic that is now owned by Elan. I have a current Elan system controlling a pool through that serial brick via ip on port 10001. When I tryed to watch watch what commands were being sent, it locked up and had to be reset.
toggle quoted message
Show quoted text
I too am looking for a way to interface with this device from an mc3. Anyone else had any luck with this? --- In Crestron@..., "Brylliantworks" <bryn@...> wrote:
|
Re: Help with a tutorial
connect_http is not the same signal as http_connect. Unless there's
toggle quoted message
Show quoted text
something else connecting those signals together, that's a "broken wire". http_connect is going high, but the signal to your TCP/IP client is named connect_http, so nothing ever happens. On Fri, Aug 16, 2013 at 11:53 AM, toplegit <toplegit@...> wrote:
Hi, --
Jeremy Weatherford |
Re: DirecTV H25 via the external Remote port
Or ip
toggle quoted message
Show quoted text
--- In Crestron@..., "antosanmar" <asandoval@...> wrote:
|
Re: PRO3 Random reboot
Ethernet heavy? IE lots of Ethernet devices and lots of inter processor send between programs?
toggle quoted message
Show quoted text
--- In Crestron@..., Nathan Hesson <nhesson@...> wrote:
|
Re: 3-series out of bounds array references FYI...
I was bit by this one.
Boy did it kill some time. The code was littered with Print statements to verify execution from event handler to function to function to my insanity... It would be great if that error entry was sent back as a TRACE as well so that you get a nice notice in your face. The 3-Series log is so verbose that items get lost quite easily after a day of loading and testing. On Wed, Aug 14, 2013 at 9:05 PM, Chip <cfm@...> wrote: ** [Non-text portions of this message have been removed] |
Core3 Graphics help please
I don't have any real time to mess around and just want to use a couple button types from my non core3 projects. Two questions.
Is the only way to 'quickly' do this using modes for every graphic 'button', or, is there a way to make the button size snap to the custom graphic on an advanced button rather than the graphic conforming to the button size itself? |
Re: PRO3 Random reboot
I don't get any message close to that. I actually can't get a message out
toggle quoted message
Show quoted text
of the processor as to why the HW Watchdog fails. The most consistent message I see in my PLOGs before the reboot occurs is: Warning: LogicEngine.exe [App 1] # 13:20:28 8-13-2013 # RuntimeState - Sysdog did not wake us up for 30 seconds Warning: nk.exe # 13:20:41 8-13-2013 # WDG: SimplSharpPro.exe(1) Watchdog Fault - Notifying Application Warning: nk.exe # 13:20:41 8-13-2013 # WDG: LogicEngine(0) Watchdog Fault - Notifying Application Warning: nk.exe # 13:20:41 8-13-2013 # WDG: RouterTransportProcess(1) Watchdog Fault - Notifying Application The NVRAMREBOOT entry says: 07:38:37 8-16-2013 HW Watchdog timeout Very informative :) I'm getting a reboot every 13-16 hours. I'm going to call TB later today and try to have this escalated but I'm curious if anyone has any other ideas. Thanks, -Nathan On Fri, Aug 16, 2013 at 8:51 AM, Witmarquzot Dyrjuv <witmarquzotix@...
wrote: What is the message? close to this? |
Re: DirecTV H25 via the external Remote port
So sorry...I read the manual and this input seems to be for some RF external adapter for RF remotes, so...flasher it is.
toggle quoted message
Show quoted text
--- In Crestron@..., "antosanmar" <asandoval@...> wrote:
|
Re: Can't import RSDs anymore?
I?m using thunderbird to post. Correcting the post via web.
toggle quoted message
Show quoted text
Did someone found a solution for it? I?m doing my first D3 Project and I can export the RSD but when try to import it in an EISC it doesn?t allow me to select this option. Main Processor is a CP2E Light Processor is a MC2E. Lots of iLux, dimmers, keypads and switches. Signed, Rafael Costa --- In Crestron@..., Rafael Costa <rafaelg.costa@...> wrote:
|
Re: How would you parse this data?
Is the protocol available publically? If yes, post to files section of Group and let us know.
I can help with this and sure that others may join in as we collectively love a challenge :) Tray From: jonathan_bbi Sent: Friday, August 16, 2013 12:08 PM To: Crestron@... Subject: [Crestron] Re: How would you parse this data? It's a Lab Gruppen NLB-60E, there is a module on Crestron's site, but it's not even close to working correctly. The only thing I can think of is that the latest firmware drastically changed the command format, otherwise, the programmer was so high he couldn't comprehend anything. :)I'm in precisely the same boat. The crestron module on the lab gruppen website and the crestron website has very little in common with the current protocol for the device. Lab gruppen tech support is spectacularly unhelpful. If you managed to cobble together a module for this, any chance you could post it in the modules section to save me a day of parsing hell? Thanks! |
Re: 1080p h.264 preview on TSW-1050
Eric Williams
One of these may work for you. I looked at some of their APIs at infocomm, should do it??? -----Original Message-----
From: "Neil Dorin" <neildorin@...> Sent: ?8/?16/?2013 11:40 AM To: "crestron" <Crestron@...> Subject: Re: [Crestron] 1080p h.264 preview on TSW-1050 FYI I tested this using the RTSP streaming output of a CAPTURE-HD-PRO set to 720p60 sending to an embedded video window on a TSW-1050 and it works flawlessly. Great quality too. On Fri, Aug 16, 2013 at 9:01 AM, Neil Dorin <neildorin@...> wrote: Yeah, client doesn't want to wait a few months. The primary sources for [Non-text portions of this message have been removed] ------------------------------------ Check out the Files area for useful modules, documents, and drivers. A contact list of Crestron dealers and programmers can be found in the Database area. Yahoo! Groups Links [Non-text portions of this message have been removed] |
Re: Can't import RSDs anymore?
Did someone found a solution for it?
I?m doing my first D3 Project and I can export the RSD but when try to import it in an EISC it doesn?t allow me to select this option. Main Processor is a CP2E Light Processor is a MC2E. Lots of iLux, dimmers, keypads and switches. Signed, Rafael Costa Em 04/06/2013 17:59, Tres escreveu:
[Non-text portions of this message have been removed] |
Re: How would you parse this data?
It's a Lab Gruppen NLB-60E, there is a module on Crestron's site, but it's not even close to working correctly. The only thing I can think of is that the latest firmware drastically changed the command format, otherwise, the programmer was so high he couldn't comprehend anything. :)I'm in precisely the same boat. The crestron module on the lab gruppen website and the crestron website has very little in common with the current protocol for the device. Lab gruppen tech support is spectacularly unhelpful. If you managed to cobble together a module for this, any chance you could post it in the modules section to save me a day of parsing hell? Thanks! |
Help with a tutorial
Hi,
I'm trying to follow a very simple tutorial to send out a GET http request. This is the tutorial in question: I've been following the tutorial word for word but I am not having success. Believe it or not I've spent many hours trying different things to no avail. I was hoping someone might be able to shed some light. Below is a screenshot of how I set it up in simpl windows, and then what I see in the debugger when I try pulsing http_go. I can never see anything come in on http_rx. As per the tutorial I verified that when I execute 'testdns google.com' in the text console I do get a proper IP address back. Any help is appreciated! Thanks! |
Re: PRO3 Random reboot
What is the message? close to this?
toggle quoted message
Show quoted text
REBOOT: 00:00:00 00-00-00 QM-RMC v4.003.0015 4355, HW Watchdog, Task=TIMER, RAM=21740560, PC=806ad250, Stk=80571adc,805714cc,80500c8e,806b1e36,806acfc0,806af42e,806a6cc4,806a683a,806abdda,806a133c,0, --- In Crestron@..., "Pleasant Bud" <mbuddycoughlin2002@...> wrote:
|
Re: 1080p h.264 preview on TSW-1050
FYI
toggle quoted message
Show quoted text
I tested this using the RTSP streaming output of a CAPTURE-HD-PRO set to 720p60 sending to an embedded video window on a TSW-1050 and it works flawlessly. Great quality too. On Fri, Aug 16, 2013 at 9:01 AM, Neil Dorin <neildorin@...> wrote:
Yeah, client doesn't want to wait a few months. The primary sources for |
Re: Christie HD6K module
Bueller? Anyone?
toggle quoted message
Show quoted text
I'm looking at the protocol manual and the example commands don't resemble what the HD5K module is sending out. Somebody has to know which module I should be using.... --- In Crestron@..., Neil Dorin <neildorin@...> wrote:
|
Re: OT: Laptop Bags?
cyberbri24
There a lot of nice options with all of these. I especially like the separate case just for your sunglasses. I actually scratched a really nice pair of mine a couple years ago which kinda sucked. I think they were 290 that I got for only 150 (Maui Jims Sandbar in black) I did work for a Vision client and hooked me up 8 yrs ago. Sadly they are now at the bottom of the ocean. Gigantic wave took them last week. Ugh! I am now thinking a new backpack for this option to keep the new pair from getting scratched.
toggle quoted message
Show quoted text
cyberbri --- In Crestron@..., Jesus Tossas <audioandnetartist@...> wrote:
|
Re: PRO3 Random reboot
I'm using , I believe four serial devices. I have four programs running. It seems to reboot ABOUT every 25 - 27 hours.
toggle quoted message
Show quoted text
--- In Crestron@..., Phil Bridges <gravityhammer@...> wrote:
|