VT-Pro..."suspicious swf object" followed by program crash

davidglassman30
 

Hi everyone,

Just wanted to throw this one out there and see if anyone else has run into it. Have an open ticket with Crestron but I tend to get a quicker response from the forum so I'm giving it a shot too.

Working on a Core3 panel in VT-Pro. Put several hours into it and didn't have any issue opening or saving it last week. Come in this morning ready to work on it further and I'm greeted with an error message("found a suspicious swf object. It will be removed") followed by an immediate crashing of VT-Pro. No changes to file, programs or settings on my end since last opened.

Very fearful my work is lost. Any potential solutions would be greatly appreciated! Thanks!

-Dave


Re: Weird Network issues between Crestron products as of late?

 

We have had the same issues at a clients house with a CP2E talking to a Pro2 and a Pac2mini. We have been working with Crestron engineers on the issue and they sent us a BETA firmware that seems to have fixed the issue. We were running the 4.007.00 fimware on both with the same UNKNOWN in the IP table.

Crestron said the "root of the problem is a network link that is going down and back up very quickly ¡­ in very short amount of time. This causes us to overwrite the link-up state with the link down state. We will have a firmware that addresses this tomorrow, so this is an option. We could also put the switch on a UPS if all the Crestron processors are connected to the same switch. This would presumably prevent this short cycling. The FW will be a pre-release and it will take some time for this to work its way through our Full QE (Quality Engineering) testing cycle and become incorporated into a released version. Please first explore adding a UPS to the switch (they can do that right now), but if we need to employ the pre-release FW we can do that when its available later this week."

I would contact support regarding the issue and see if they will give the firmware to try.

Eric
Xen Technology Group, LLC

--- In Crestron@..., "jac777888" <jchelton@...> wrote:

Also, I have had similar networking issues with using the LAN's PoE switch to supply PoE power to DMCO-55 cards, when connected, I would intermittently loose connection to CP2E, then disconnect PoE feeds to output cards and it cleared up. Also throughput on the LAN dropped significantly. Using PoE injectors solved the problem.


--- In Crestron@..., "innoventgroup" <innoventgroup@> wrote:

Just FYI, I just finished fighting the same type of issues. All of the sudden I had the same network problems with multiple, non-connected, systems. Come to find out, there were two main issues. First, I had ADMS's at both locations and both were a major contributor to the problem. I could unplug them and the problems went away, plug them back in and the problems would return. Also, another culprit was the 4.007 firmware update. And, finally, the center point of the problem was a Netflix 8 port gigabit switch. I switched it out for a cisco 16 port gigabit switch and all is well. I still get errors on the 4.007 firmware but they are not killing my systems anymore. By the way, you can get rid of the 4.007 errors by rolling back the firmware to the previous version. I hope something in my babbling will help.

Take Care,
DAVE

--- In Crestron@..., "toritian" <toritian@> wrote:

Has anyone else experience weird network connection problems between Crestron equipment with recent updates?

I have had DM Router issues, where it will show the DM Router as being offline until I reboot the DM and then it pops back up online in the IP Table.

This happened in multiple locations with multiple programs/DMs.

On another site I have CP2E running lights talking to another CP2E and I'm having a hell of a time getting them to talk to each other over an EISC.

A reboot of both will usually connect them up for a while, but then they will stop talking.

One processor is showing a status of "UNKNOWN" and the other shows a connection status of "NO_NETWORK", which I don't remember seeing before.

I gave up using Direct Sockets because they seem broke, but this is just basic Crestron 101 falling apart.


Re: Upgrading RAM memory to my Mac Book Pro

Jesus @ Audio& Net Artist
 

Nice page for Mac stuff! thanks for the link, yeah looks like I can go up
to 16G wish I thought only 8G were capable (don't know why) but ill update
to 16!!

!--


*Jesus Tossas*
*
*
*Technology Architect, Audio Engineer, Programmer*
*
*
*787-460-1223*
*
*
Contact Info <>


Re: Upgrading RAM memory to my Mac Book Pro

Joseph K. Vossen
 

I've purchased my macbook pro upgrades (new internal disk and memory) at OWC (<>)

just plug in the type of machine you have and they will recommend the proper part(s)

good service and reasonable prices

HTH

-----Original Message-----
From: gsusmood <audioandnetartist@...>
Sent: Mar 25, 2013 8:24 AM
To: Crestron@...
Subject: [Crestron] Upgrading RAM memory to my Mac Book Pro

For those running Parallels, My mac have stock RAM 4G. am planing the upgrade to 8G, Anyone have any particular brand tested to get better performance on the Crestron Apps or overall? AM thinking that any update to the RAM will improve compiling and some weird opening windows thinking circle...


Re: Going mad... xPanel

 

Hold down Ctrl and hit refresh. It forces IE to download a fresh uncached
copy. When I was a web designer this was a common fix to a common problem
of old content.

Nick

Sent from my eMail.

On Mar 25, 2013, at 8:09 AM, pmwilliams8720 <pmwilliams1@...> wrote:





This might sound silly but have you reloaded the webpage? I know it sounds
strange but I've had this exact issue before. Clearing temp files via
CCleaner and Internet Options does nothing until I explicitly reloaded the
page via IE's refresh button.

- Patrick

--- In Crestron@..., "olly_penguin" <oliver.hall@...> wrote:

This will only remove the 64-bit web Xpanel executables, which is valid
if you can't get the xpanel to *fit*, but they have nothing to do with the
panel design.

--- In Crestron@..., "rabih" <marselle001@> wrote:

To Make the web xpanel work please follow the steps below:

After Compile , open xpanel web folder and delete every file has 64 ,
mainly they are 2 files :

XPanel64
XInit64

then it should work !

Rabih Brahim
Crestron CAIP



[Non-text portions of this message have been removed]


Upgrading RAM memory to my Mac Book Pro

gsusmood
 

For those running Parallels, My mac have stock RAM 4G. am planing the upgrade to 8G, Anyone have any particular brand tested to get better performance on the Crestron Apps or overall? AM thinking that any update to the RAM will improve compiling and some weird opening windows thinking circle...


Re: DM System without Processor

 

Thanks guys for the help.

I appreciate it.

Thom

--- In Crestron@..., Lincoln King-Cliby <lincoln@...> wrote:

Yes, only nitpick is that the -transmitter- needs to be set to autoswitch (the out of the box default) to allow either VGA or HDMI to be connected; there is nothing in the scaler to switch...what comes in the DM input gets scaled and goes out the HDMI output.

--
Lincoln King-Cliby, CTS
Sr. Systems Architect | Crestron Certified Master Programmer (Silver)
ControlWorks Consulting, LLC
Crestron Services Provider

-----Original Message-----
From: Crestron@... [mailto:Crestron@...] On Behalf Of crestronprogrammingfun
Sent: Sunday, March 24, 2013 2:22 PM
To: Crestron@...
Subject: [Crestron] DM System without Processor

Does anyone know if this will work...
A dm wall plate and a dm scaler only. No processor. Set the scaler up for auto detect to allow vga or hdmi to be plugged in.

Thoughts?

Thanks
Thom



------------------------------------



Check out the Files area for useful modules, documents, and drivers.

A contact list of Crestron dealers and programmers can be found in the Database area.
Yahoo! Groups Links


Re: Going mad... xPanel

 

This might sound silly but have you reloaded the webpage? I know it sounds strange but I've had this exact issue before. Clearing temp files via CCleaner and Internet Options does nothing until I explicitly reloaded the page via IE's refresh button.

- Patrick

--- In Crestron@..., "olly_penguin" <oliver.hall@...> wrote:

This will only remove the 64-bit web Xpanel executables, which is valid if you can't get the xpanel to *fit*, but they have nothing to do with the panel design.

--- In Crestron@..., "rabih" <marselle001@> wrote:

To Make the web xpanel work please follow the steps below:

After Compile , open xpanel web folder and delete every file has 64 , mainly they are 2 files :

XPanel64
XInit64

then it should work !

Rabih Brahim
Crestron CAIP


Hardware, pulled from a job site

 

Hey guys,

We should be pulling some hardware from two job sites that we are upgrading.


AV2 with Ethernet card (C2ENET1)

433 MHz 1way gateway

Tps4L with aluminum frame (2)



Also, I'll have a complete 12 zones adagio system with apads.


Anyone interested drop me a direct email.

Thanks !


Re: Going mad... xPanel

 

This will only remove the 64-bit web Xpanel executables, which is valid if you can't get the xpanel to *fit*, but they have nothing to do with the panel design.

--- In Crestron@..., "rabih" <marselle001@...> wrote:

To Make the web xpanel work please follow the steps below:

After Compile , open xpanel web folder and delete every file has 64 , mainly they are 2 files :

XPanel64
XInit64

then it should work !

Rabih Brahim
Crestron CAIP


Re: MJPEG encoder suggestions

 


Re: MTX 3 battery level analog join

 

I always used the device extender in Simpl successfully. I do however run across a problem about 25% of the time where the unit will not properly report battery levels at all, not even in its internal setup. When this happens, in setup the battery reports as 0% at all times. The solution is to RMA if this condition exists.

hth, erik

--- In Crestron@..., "Gerard" <galcala@...> wrote:

Is the reserved join for battery level 17507? I'm trying to indicate the current battery level on a MTX3 and am not having success.

Thanks.


Re: Going mad... xPanel

Albert Brown
 

This is something I use when updating webpages.



Open command promt and enter the following ( ipconfig /flushdns ) this will
make sure it will reload from the server.



Albert



From: Crestron@... [mailto:Crestron@...] On Behalf
Of rlf79cm
Sent: Sunday, March 24, 2013 7:32 AM
To: Crestron@...
Subject: [Bulk] [Crestron] Re: Going mad... xPanel





Ok, I tried it on a new PC and it shows the new design, but on the PC's
which have already run the older design it doesn't update, so I guess this
is an IE cache problem rather than Crestron - never seen it before tho!

--- In Crestron@... <mailto:Crestron%40yahoogroups.com> ,
"rlf79cm" <rlf79cm@...> wrote:

Tried that, both with the IE options and CCleaner to clear everything -
still showing old design :o(

--- In Crestron@... <mailto:Crestron%40yahoogroups.com> ,
trayschaeffer <trayschaeffer@> wrote:

Clear the temp files from your browser. That's all I can think of right
now...

Tray




Sent from my Samsung Galaxy Note???, an AT&T LTE smartphonerlf79cm
<rlf79cm@> wrote:
I've updated my xPanel but whenever I compile and run it through the
browser it's showing the old version - I've tried renaming, running it from
the PC, processor, etc - always showing the old version. If I compile as an
exe the new design works fine, but I can't for the life of me get the
browser version to update.

Never seen this before - any ideas?

Cheers, Rick



[Non-text portions of this message have been removed]




[Non-text portions of this message have been removed]


MTX 3 battery level analog join

 

Is the reserved join for battery level 17507? I'm trying to indicate the current battery level on a MTX3 and am not having success.

Thanks.


Re: Analog output

 

Depends on the way the trigger to whatever module you're using is written/intended to be used but generally "only once".

Most SIMPL+ logic, for example, is edge triggered -- the action occurs on the rising or falling edge of the signal [e.g. high to low or low to high]. Some logic, though is level triggered, for example a RAMP in SIMPL+ where the action occurs for as long as the signal is high (or low)

Lincoln

-----Original Message-----
From: Crestron@... [mailto:Crestron@...] On Behalf Of rlf79cm
Sent: Sunday, March 24, 2013 5:36 PM
To: Crestron@...
Subject: [Crestron] Re: Analog output

Quick one, if I tie the < digital output to a trigger email event will it send the email just once, or continually send it until the < is no longer high?

Cheers

--- In Crestron@..., "Chip" <cfm@...> wrote:


ACOMP2 and a debounce to make sure the temp is stable before triggering the email?

- Chip


--- In Crestron@..., "rlf79cm" <rlf79cm@> wrote:

What's the best way to trigger an event based on an analog output from a C2N-RTHS sensor? The sensor has one Temp and one Humidity output, and I'd like to send an email when temp gets below 12 degrees.. (the email side things is all written and the sensor is outputting correctly - just not sure if the symbol inebtween the two)

Cheers!



------------------------------------



Check out the Files area for useful modules, documents, and drivers.

A contact list of Crestron dealers and programmers can be found in the Database area.
Yahoo! Groups Links


Re: DM System without Processor

 

Yes, only nitpick is that the -transmitter- needs to be set to autoswitch (the out of the box default) to allow either VGA or HDMI to be connected; there is nothing in the scaler to switch...what comes in the DM input gets scaled and goes out the HDMI output.

--
Lincoln King-Cliby, CTS
Sr. Systems Architect | Crestron Certified Master Programmer (Silver)
ControlWorks Consulting, LLC
Crestron Services Provider

-----Original Message-----
From: Crestron@... [mailto:Crestron@...] On Behalf Of crestronprogrammingfun
Sent: Sunday, March 24, 2013 2:22 PM
To: Crestron@...
Subject: [Crestron] DM System without Processor

Does anyone know if this will work...
A dm wall plate and a dm scaler only. No processor. Set the scaler up for auto detect to allow vga or hdmi to be plugged in.

Thoughts?

Thanks
Thom



------------------------------------



Check out the Files area for useful modules, documents, and drivers.

A contact list of Crestron dealers and programmers can be found in the Database area.
Yahoo! Groups Links


Re: Analog output

 

Quick one, if I tie the < digital output to a trigger email event will it send the email just once, or continually send it until the < is no longer high?

Cheers

--- In Crestron@..., "Chip" <cfm@...> wrote:


ACOMP2 and a debounce to make sure the temp is stable before triggering the email?

- Chip


--- In Crestron@..., "rlf79cm" <rlf79cm@> wrote:

What's the best way to trigger an event based on an analog output from a C2N-RTHS sensor? The sensor has one Temp and one Humidity output, and I'd like to send an email when temp gets below 12 degrees.. (the email side things is all written and the sensor is outputting correctly - just not sure if the symbol inebtween the two)

Cheers!


Re: URC MX980 wont work with my STRFGWX

 

Yea I got one on eBay today for 65$.

Am I the only one that has a stock pile of equipment left over from jobs and its never what I need.... ? Lol

Thanks for the help y'all.

--- In Crestron@..., "eagrubbs" <eagrubbs@...> wrote:

Good catch, I didn't see/read the "ST" part. Yep, must be the 1-way gateway.

--- In Crestron@..., "Ted" <ted_brincka@> wrote:

Mark, it will work with the CNRFGWA-418. Ted

--- In Crestron@..., "Mark" <dedicatedsystems@> wrote:

So i bought a URC MX980 and was thinking since the STRFGWX is 418mhz it would work as the receiver.

Am i wrong? I cant drop it in on the symbol... WTH?

and i have another gateway but yep it is a CNRFGWA... that is 418mhz.

so am i screwed?


please understand, i am a commercial guy we do not do allot of handheled remotes..


Re: Analog output

 

Perfect - exactly what I needed. Thanks Chip

--- In Crestron@..., "Chip" <cfm@...> wrote:


ACOMP2 and a debounce to make sure the temp is stable before triggering the email?

- Chip


--- In Crestron@..., "rlf79cm" <rlf79cm@> wrote:

What's the best way to trigger an event based on an analog output from a C2N-RTHS sensor? The sensor has one Temp and one Humidity output, and I'd like to send an email when temp gets below 12 degrees.. (the email side things is all written and the sensor is outputting correctly - just not sure if the symbol inebtween the two)

Cheers!


Re: Analog output

Chip
 

ACOMP2 and a debounce to make sure the temp is stable before triggering the email?

- Chip

--- In Crestron@..., "rlf79cm" <rlf79cm@...> wrote:

What's the best way to trigger an event based on an analog output from a C2N-RTHS sensor? The sensor has one Temp and one Humidity output, and I'd like to send an email when temp gets below 12 degrees.. (the email side things is all written and the sensor is outputting correctly - just not sure if the symbol inebtween the two)

Cheers!