Re: Simpl+ with "" as the default string parameter value
Tony is right, the only way to have an empty string parameter default to "" in SIMPL when you drag in a module is to do what Tony said, edit parameter properties (in .umc) and set default value to "".
Logically pretty much impossible to do that in Simpl+. |
Re: PRO4 with C3-IR
¿ªÔÆÌåÓýRan into something similar the other day with a PRO4 and relay cards. ?Apparently the cards communicate over IP through the processor and since they were developed for the 3-Series they fail with HOSTNAMES that are over 13 or 15 characters (can¡¯t recall). ?Try shortening the HOSTNAME on the processor and see if that resolves your issue.
|
Re: PRO4 with C3-IR
¿ªÔÆÌåÓýThey show up in Text Console with the cards or showhw commands, all looks good, there are led¡¯s on the front for Slots 1,2,3, they are flashing green which is a little concerning I guess ? Sent from From: [email protected] <[email protected]>
On Behalf Of ckangis
Sent: Saturday, February 24, 2024 1:27 PM To: [email protected] Subject: Re: [crestron] PRO4 with C3-IR ? Do they show up when you look at the front panel to see the installed cards?? (I'm assuming that you can do this like on the old Pro2's...) |
Re: PRO4 with C3-IR
¿ªÔÆÌåÓýUggh, does not seem to matter ? Sent from From: [email protected] <[email protected]>
On Behalf Of Daygecko
Sent: Saturday, February 24, 2024 12:08 PM To: [email protected] Subject: Re: [crestron] PRO4 with C3-IR ? Is the source code compiled for both 3 & 4 series? I don't know that it makes a difference...Just a thought. |
Re: Simpl+ with "" as the default string parameter value
Have you tried wrapping it in a umc, then setting the parameter properties in Simpl?
toggle quoted message
Show quoted text
--- On Saturday, February 24, 2024 at 2:04 PM, Devin Cook wrote: |
Re: Simpl+ with "" as the default string parameter value
Thanks for the suggestion. Unfortunately it didn't work. --Devin On Sat, Feb 24, 2024 at 5:42?AM jbasen <jay.m.basen@...> wrote:
|
Re: PRO4 with C3-IR
¿ªÔÆÌåÓýCorrect, They are brand new C3IR-8 cards, I have 1 card in a PRO4 and 2 cards in a different PRO4, none of them work ? Sent from From: [email protected] <[email protected]>
On Behalf Of ckangis
Sent: Saturday, February 24, 2024 10:44 AM To: [email protected] Subject: Re: [crestron] PRO4 with C3-IR ? Just to confirm, you're using C3IR-8 cards with your Pro4?? the Pro2 used C2IR-8 cards that are not compatible with the Pro4... |
Re: Simpl+ with "" as the default string parameter value
¿ªÔÆÌåÓýI'm not sure if this will work for you without doing a bunch of
testing, but it sounds like S+ believes that it is OK to put a 0d
in your parameter field that should only be accepting a string.?
Try setting the following in your parameter properties. propValidUnits = unitString; Hope this helps Jay On 2/24/2024 4:04 AM, Devin Cook wrote:
I've written a Simpl+ module with a massive amount of string parameters and to make the module as user friendly I would like have them fill with "" by default.?? |
Re: Zoom with Flex Systems
We regularly have to integrate either teams or zoom with crestron, and indeed it is complicated each time.
It's been a while since I interacted with Zoom but it seemed to me that you could stay on the control interface more easily than for Teams where you have to constantly activate a "hold" to stay in control mode.
I find that the most frustrating thing is not being able to manage the "ingest" part in teams => we cannot tell the machine to stop sharing content if the last user has left the meeting. ... |
Simpl+ with "" as the default string parameter value
I've written a Simpl+ module with a massive amount of string parameters and to make the module as user friendly I would like have them fill with "" by default.??
I've tried about every combo I can think of for the?propDefaultValue but alas, no luck.? And for some reason Simpl like to fill in the values with a 0d if you tell it to complete the block. Any hints on the syntax?? I tried """", "\x22\x22" and "\"\"" along with everything I could think of. Anyone get this to work? Thanks |
Re: TSR-302 Voice Control Issue
It's the same output.
toggle quoted message
Show quoted text
There's a special section in the remote's Setup Menu, where it can be registered to use one of the cloud processing services - I believe only the TSR-310 has this. Once registered, that voice capture feedback signal contains the PROCESSED voice output. If the touchpanel isn't registered with a cloud service, the voice capture output contains the raw text-to-speech. And there's a HUGE difference between the two :-) --- On Friday, February 23, 2024 at 2:03 PM, giblp44 wrote: |
Flex with QSC Control
Hi. Is there a way to delete the Crestron "page 2" application from a Flex system, so a different "page 2" (QSC) can be installed instead? |
Re: UC-MX50T speakerphone issue
¿ªÔÆÌåÓýPS these units have been in service for over a year, so it is not some commissioning error ? From: <[email protected]> on behalf of Kol Johnson <kol.mstc@...> ? echo cancelling speakerphone isn¡¯t connected ?(?!) |