Keyboard Shortcuts
Likes
- Crestron
- Messages
Search
Re: Honeywell Vista-21IPSIA
#simpl
a. The Vista-21 iPSIA is just a Vista-20 with an IP communications board that speaks specifically SIA protocol.
b. as Tony mentioned, it uses the CBM module, which I've heard is not great - we've always had the Security contractor upgrade the panel to a 128BPT which has the serial port built onto the main board... Tony, What is your recent experience with the Vista-20 and the CBM module, particularly if you've compared it with the 128/250BPT systems?? ?TIA!! |
Re: Honeywell Vista-21IPSIA
#simpl
It uses the 4232CBM serial adapter, and accompanying Simpl module.
toggle quoted message
Show quoted text
--- On Wednesday, October 12, 2022 at 4:06 PM, Alex Teague wrote: |
Honeywell Vista-21IPSIA
#simpl
I'm supposed to program a?Honeywell Vista-21iPSIA in SIMPL and I can't find a module or anything indicating the existence of a module. I do however see that this model is listed as compatible with CH. I have a CH processor on site and can use the PYNG smart object but I'd rather not if I don't have to. Anyone know if a SIMPL module exists or if there's another module that might work for this series?
|
Re: Cisco Room Devices 3.4 issue
#crestron
was released Jul.2019 for use with DB v115 or below. Have you tried updating the program to use the latest module version, or tested with the v4 demo? |
Re: Updating CLZ
#simplsharp
On Tue, Oct 11, 2022 at 11:28 PM, Tony Golden wrote:
This service should be able to take care of it...I second this service!? |
Cisco Room Devices 3.4 issue
#crestron
hi everyone?
i use cisco room devices 3.4 and xhen i receive a meeting invitation from teams i can't join the meeting. when i click on the ''JoinActiveBooking''button, nothing happens. what could be the problem? |
Re: Crestron Home simple relay driver
The CCD SDK (the SDK required for extension devices in Crestron Home) doesn't provide access to the general processor hardware directly, but you could write a driver to fire events and hook it up that way.
I doubt there's a driver already written that does exactly what you want, so the "DIY" open is probably your best bet - though the CCD SDK is a bit of a minefield! Best of luck, Oliver |
Re: File /Programs/CI-KNX v1.6.zip uploaded
#file-notice
Hello math leenen I have run the program and I have try to send command through simpl dibugger? to switch for 4 channel knx actuator but? command not execute and actuator not perform task kindly guide where I am wrong?
I have done all necessary step example like I have assigned the group address to actuator as well ci knx and make static IP of ci knx |
Re: Updating CLZ
#simplsharp
This service should be able to take care of it...
toggle quoted message
Show quoted text
--- On Tuesday, October 11, 2022 at 7:06 PM, Daniel Portugal wrote: |
Re: DSC PowerSeries Neo
I did login to try to read this article, but it says "the answer is no longer available".? I wrote to Crestron True Blue support, they gave me a detailed explanation and solution with screen shots. I'm happy to share it here but I have no way to upload photos and screenshots.? ? Anyway the problem is resolved now. Thanks everyone for your help! |
Topics in Home Automation - New Article in Residential Tech Today
¿ªÔÆÌåÓýMy latest article, "Health and Fitness Tracking with the Withings
ScanWatch¡± is being published by the good folks at Residential
Tech Today Magazine on their web site. You can find the article here:
|
Updating CLZ
#simplsharp
I received an old program.
Compiling it gives an error: "SimplSharpParseJson.usp : simplsharphttplibrary.dll cannot be used due to a dependency on Newtonsoft.Json.Compact, version 3.5.0.0.. Press Help for details." Is it possible to just replace the common DLL files in the CLZ with new ones? Obviously the best case scenario is that that I would have the VS2008 solution and related files to be recompiled. |
Re: Crestron Home simple relay driver
Thank you all for your help and suggestions,
I already have CP3 with Crestron Home Triggers events, but finally I want to remove CP3 and use only CP4-R. The best for me could be simple driver to control relays in CP4-R. I am S# beginner so maybe there will be someone to share such driver.
?
If not I will try to write something by myself. |
Re: TSR-310 xPanel test
TSR-310 doesn't support XPanel emulation; official stance is that you need the physical remote to test at this time. When running a TSR-310 .vtz as XPanel you won't have an option to Enable Faceplate to emulate hard buttons. Only TSR-302 .vtz has an associated faceplate. When in SIMPL you won't have a "TSR-310 - XPanel 2.0 Simulator" definition under the list of Ethernet devices. Only TSR-302 has a "simulator" hardware definition. TSR-310 hw def isn't viable because it handles update requests / feedback differently. I'm not sure offhand if you can point it to TSR-302 simulator def to get it partially working in the meantime. These items were being tracked in BR 739 "TSR310 - XPanel Emulator Issues - Not Updating Joins & Faceplate Missing." This groups.io thread was added to BR 739 for tracking. |