Re: Converting AMX Module to Crestron Module
It is a TriplePlay Server that communicates to each TriplePlay Play3R-SP1 signage players. Uses JSON for all communication. Working on creating control via C# but just not adverse in C# yet.
I would look at any module to get me going in the right direction. |
Re: Converting AMX Module to Crestron Module
Hi Brad,
I'm thinking that there's no easy way to convert. probably the best way is to have both open side by side and just copy/paste the concepts into SMW If you're talking about the Antex SRX-3 Sirius TriplePlay unit, I may have an old module to at least get you started...LMK |
Re: Replacement for multichannel amplifier
¿ªÔÆÌåÓýHi Angel, ? the Dayton Audio i?m using is pretty simple ¨C no Crestron control involved. I?m using the input sense functionality of the amplifier, so each zone independently powers up when music playback starts. The amplifier can also be turned on using a 12V trigger, but that would fire up all zones which i don?t want to. ? HTH ? Cheers, Thorsten ? Von: [email protected] <[email protected]> Im Auftrag von Angel Marti ? Hello all, |
Re: Replacement for multichannel amplifier
Hello all,
Thorsten, how did you controll the Dayton Audio amp, just commands or with some module? I'm just started a project using a Dayton Audio amplifier, but I haven't found any module for it yet. Would you share something I can use for make it work? Thank you, Angel. |
Mag322 (Infomir) STB?IR?code ?
Hi
Looking for some IR captures of remote of Infomir STB (more specifically MAG322) although it looks to be same remote for all models. I found out an IP protocol but it looks quite cumbersome to get simple commands control. Someone got experiences with these ? or IR capture of the remote ? Thanks ³Õ¾±²Ô³¦¨¨²Ô |
Re: S# Pro on RMC4 with a DM-XIO-DIR
#rmc4
Are you familiar with Answer ID?1000315?? Even with less than 65 endpoints defined, I have still seen similar issues with overloading the processor - I would recommend trying the commands in that section to see if it improves things. On Thu, May 26, 2022 at 11:45 AM Mark via <junkmailhangar=[email protected]> wrote: I have a program that defines a director, four NVX units, adds them to the unit and then registers the lot. I receive very odd messaging in the error log and am not sure where to begin looking. Another odd behavior is attempting to stop the program takes a very long time. Has anyone seen this before: |
Re: SW-VMK-WIN
¿ªÔÆÌåÓýYeah, i think it?s similar to EventGhost which i?ve used in the past. I was just thinking using the Crestron tool would be easier to interface as there are already drivers in SIMPL, but if the tool isn?t working, that?s not helping. ? @Chris ? Cheers, Thorsten ? Von: [email protected] <[email protected]> Im Auftrag von Geoffrey Reynolds ? MCE Controller works really well: ? ? Pair it with a TCP Client symbol in your SIMPL program and you're good to go.? I've been using it for years without any issues. ? Geoff ? On Mon, May 30, 2022 at 4:09 PM Thorsten K?hler <thorsten.koehler@...> wrote:
|
Re: SW-VMK-WIN
If you¡¯re asking about MCE controller, I think so, but I have only used it to initiate actions on the PC from the Crestron side. Geoff On Mon, May 30, 2022 at 7:55 PM ckangis <chris@...> wrote: Just curious, |
Re: SW-VMK-WIN
MCE Controller works really well: Pair it with a TCP Client symbol in your SIMPL program and you're good to go.? I've been using it for years without any issues. Geoff On Mon, May 30, 2022 at 4:09 PM Thorsten K?hler <thorsten.koehler@...> wrote:
|
SW-VMK-WIN
¿ªÔÆÌåÓýHi, ? i need to control a Windows 10 PC from a Crestron touchpanel and wanted to give the VMK-WIN a try. It installs fine and the service is running, but it doesn?t seem to work correctly. For instance the Crestron symbol that should appear in the system tray after reboot is missing. Any ideas or is this tool just too old for Windows 10/11? ? Cheers, Thorsten |
Re: 70 series VTP default page when processor offline
I'd do a modal subpage that is fed by the reserved join for panel offline.? On Mon, May 30, 2022, 3:01 PM RK-X <rkx1984@...> wrote: Bit of an embarrassing one here, You can display a page prior to processor online when panel boots (Page 1) *System startup, Please wait* I'm sure there was a way to display that page when the processor goes offline after successful System boot *System Failure - Call xxxxxx* |
70 series VTP default page when processor offline
Bit of an embarrassing one here, You can display a page prior to processor online when panel boots (Page 1) *System startup, Please wait* I'm sure there was a way to display that page when the processor goes offline after successful System boot *System Failure - Call xxxxxx*
I normally wouldn't bother because fusion handles notifications for Support. This is a non fusion setup with an old fashioned email alert. Did a test on a brand new panel and page 1 never shows when CP4's network is pulled. Please someone jog my memory or tell me I dreamt it... |
Biamp Tesira X400 - VOIP dialer not controlled via Crestron
Good day all,?
Trying to control the VOIP dialer within a Tesira Forte X400 unit.? The dialer from the DSP/Tesira software works.? However, i cannot get the VOIP dialer to initialize with the 3.0 or 3.2 module versions.? Leve/mute/state controls work well. Just the VOiP dialer does not work at all. If I set the Enable for VOIP low, then Command processor module init completes.? I did confirm both VOIP instance names from the DSP file. Copied and pasted to be sure program tags match the DSP file.?? Any ideas of how to work around this?? Tesira Forte x 400 FW: 4.2.4.5 Thanks,? Tray #Biamp # DSP |
Re: Launching a 3rd party app from the crestron go app
#crestronapp
Hi Tony, i've only just started using shortcuts and they could be very handle. Shortcuts works like a command list or schedule list. A Shortcut can also adds a icon on the iphone home page. Basically you can use the shortcut to open one or more apps. Its a good workaround if you can't find or a app doesn't have a URL scheme.??
|