Working on a deployment with 100+ NVX devices on a single domain, NVX Director, Extreme Switches in star topology, and a Pro3. Had an issue where the processor was crashing after a reboot.?
Solved the issue, but in case anyone else runs into this problem, check out the following Crestron support article?.? It was really great that in multiple calls with True Blue, this was never mentioned. Just happened to find it on our own.? Hope this helps somebody else. [Edited by moderator to remove content that is not available without dealer access]
?
|
Opportunity at Intaglio
plarson835
¿ªÔÆÌåÓýIntaglio is looking for an experienced systems programmer to join our team. See the job link below or reply to me directly (rather than the group).
Peter Larson Founder and Chief Creative Officer Intaglio, LLC 3106 Three Mile Rd. NW Grand Rapids, MI 49534 |
Re: SWE-8 Needed. Anyone got a spare sitting on shelf?
¿ªÔÆÌåÓý? Karl, I have one, lightly used.? ? |
Re: Launching a 3rd party app from the crestron go app
#crestronapp
Because even in the security world a lot of the overflow and command execution examples called calc as it was harmless to demonstrate. Is anyone adding a flipperzero to their toolkits On Wed, May 18, 2022 at 1:31 PM JB <jbbrescia@...> wrote:
|
Re: Launching a 3rd party app from the crestron go app
#crestronapp
Interesting, i think it will the good place to share each other the link you are all using to call third party applications ? fell free to put you succes url here : |
Re: Cisco webex
Currently have a few systems running with the Cisco 4.0 modules from the Market place. With mixed results. [equip: 4 Codec Pro's]? |
Re: Poly G7500 device mode command
Do you want to change the provider mode or just go in and out of device mode for BYOD with the Poly camera/mic/etc...?
Changing providers always reboots because it is changing the underlying setup for how it communicates all the time whether its Poly / Zoom or device mode. If you are using the standard Poly mode and are just looking to turn on / off device mode you can do that from the RESTful API. I thought it had been added to the command line API but taking a quick look that doesn't seem to be there anymore. RESTful docs :? Command Line docs :?https://www.poly.com/content/dam/www/products/support/video/video-os/other/g7500-api-3-9-0.pdf |
Re: NAX Traffic crushing network
It is only Ubiquiti's Unifi line that cannot handle multicast traffic. I have several NVX installations using Ubiquiti's Edge line with no issues.? I would imagine that NAX traffic would not be quite as taxing as NVX.
toggle quoted message
Show quoted text
However, it is best to route all multicast traffic through a single switch as there is no IGMP snooping on multicast router ports. If you have several switches, you have to make sure there is sufficient bandwidth on the uplink ports to handle all multicast traffic.? For NVX you will quickly run out of bandwidth on those uplink ports. casey@...
|
Re: Cisco webex
Daniel Sartorius
I believe there is. Which module are you using to control the webex device? (guessing it's a codec).
If you are using the Cisco Room Devices 4.0, I believe that device has "message center" or "alert center" control sections, which may allow you to enter credentials. I have not had to use this yet, however, so I may be completely wrong. |
Text console command to set HDCP support
Daniel Sartorius
Is there a way to change the HDCP support of DM chassis input cards via Text Console? I know DMHDCPdisplay shows the current HDCP info per card, but is there a way to use text console to turn support on/off?
I work with systems that have 1-2 outputs connected to capture cards, so I need to be able to turn off HDCP support - which gets turned on upon firmware upgrades. I know I can do this via DM tool, but that tool takes forever to load. Thanks for any info! |
Re: CCDs and NVRAM
BR 5812 = SIMPL - CCD Display Module - v1.14-1.19 allocating NVRAM and unable to compile when using multiple instances
?
BR 5812 solved noting SIMPL+ calls storing data have been removed from v2.x modules.
In removing that code, the programmer must now send the user attribute data in at the correct time - AFTER the driver has been loaded.
The proper sequence is: Load Driver -> Loaded_FB -> Set User Attributes (including "Send it In") -> Trigger Connect
?
?
Example SIMPL programs showing this logic will be posted to the SDK-CD page resources tab soon.
? |
Re: Launching a 3rd party app from the crestron go app
#crestronapp