Re: Master 2022, no virtual option? WTF

 

has the date been released yet?


Re: TCP Client Stopped working

 

Yeah, It definitely seems very intermittent, as I at least have not seen it before...
In this case, I don't believe that the Vantage system was off-line at all (certainly not for hours/days) so it seems that the Client just disconnected itself...


Re: TCP Client Stopped working

 

¿ªÔÆÌåÓý

I¡¯ve seen an issue on my home system (PRO4) a couple times but not with enough frequency to get enough info for a proper bug report where if the Ethernet link is lost under some circumstances the connection will not retry until the program is reset. The status in the IPT is ¡°LINK LOST¡± ¨C but this doesn¡¯t happen on every link loss event. (Most recently I saw it because I was upgrading one of the edge switches in my AV equipment room)

?

The other thing to remember is that the TCP client retry time rises exponentially the longer it can¡¯t connect to the other device, e.g. the longer a device is off line the longer it will be between retrying the connection (I want to say the upper end is 65000 seconds but I¡¯ve never personally tried it) so if the device had been offline for ¡°a long time¡± that could explain why it didn¡¯t seem to be retrying.

?

Beyond those two cases though I can¡¯t say I¡¯ve seen any systematic issues with the TCP/IP client on the 3- or 4- series¡­. And I have a few applications where I know I¡¯d know if there were issues because the failure would be critically obvious.

?

?

--

Lincoln King-Cliby, CTS, DMC-E-4K/T/D
Commercial Market Director
Sr. Systems Architect | Crestron Certified Master Programmer (Diamond)
ControlWorks Consulting, LLC
Direct: (+1)440.771.4807 | Cleveland: (+1)440.449.1100? | Boston: (+1)508.695.0188 | DC: (+1)202.381.9070? | Fax: (+1)440.449.1106
Crestron Services Provider | Biamp Authorized Independent Programmers | Extron Qualified Independent Programmer

?

From: [email protected] [mailto:[email protected]] On Behalf Of ckangis
Sent: Saturday, April 09, 2022 11:22 AM
To: [email protected]
Subject: [crestron] TCP Client Stopped working

?

Hi All,
Wondering if others have seen this odd, intermittent behavior...and also a heads-up for others to watch out for it

CP4 (v2.7000.00040) has a TCP client communicating with a Vantage System (though I don't think the remote device matters).
It was working two weeks ago, and we checked yesterday (client is out of town) and found that it was 'Not Connected' and specifically not trying to Re-Connect.
The Status analog just stayed at '1d' instead of the typical toggling between 1d and 3d (Waiting for connect vs Connect Failed)
As I have a '1' on the Connect input, I could not test if toggling this would fix the issue, Rebooting the Vantage processor did not restore.
Only restarting the program slot restored the connection.

I spoke with Crestron TS to trouble-shoot this, as I've never seen this behavior before, and they have confirmed that they have seen this a few times, offering:
1. They said it was 4-series issue, spanning fw updates
2. Use an S+ emulation module of the TCP client until they fix the issue...:(

Clearly this is a specifically intermittent issue, as I have not seen anyone else talking about this lately, but they have confirmed that there is a problem....
In a related note, another friend of mine who I trust with his technical knowledge and experience, says that he has seen this issue? for years on both 3 and 4-series systems.
He feels that it is a long-standing issue that has not been dealt with and thus probably will not be fixed...
Given my experiences over the last 5+ years with TB, I would tend to agree.

To have to use a custom S+ module to handle this is absolutely ridiculous - the TCP Client is a native hardware device symbol...
What experiences have other had about this??


TCP Client Stopped working

 

Hi All,
Wondering if others have seen this odd, intermittent behavior...and also a heads-up for others to watch out for it

CP4 (v2.7000.00040) has a TCP client communicating with a Vantage System (though I don't think the remote device matters).
It was working two weeks ago, and we checked yesterday (client is out of town) and found that it was 'Not Connected' and specifically not trying to Re-Connect.
The Status analog just stayed at '1d' instead of the typical toggling between 1d and 3d (Waiting for connect vs Connect Failed)
As I have a '1' on the Connect input, I could not test if toggling this would fix the issue, Rebooting the Vantage processor did not restore.
Only restarting the program slot restored the connection.

I spoke with Crestron TS to trouble-shoot this, as I've never seen this behavior before, and they have confirmed that they have seen this a few times, offering:
1. They said it was 4-series issue, spanning fw updates
2. Use an S+ emulation module of the TCP client until they fix the issue...:(

Clearly this is a specifically intermittent issue, as I have not seen anyone else talking about this lately, but they have confirmed that there is a problem....
In a related note, another friend of mine who I trust with his technical knowledge and experience, says that he has seen this issue? for years on both 3 and 4-series systems.
He feels that it is a long-standing issue that has not been dealt with and thus probably will not be fixed...
Given my experiences over the last 5+ years with TB, I would tend to agree.

To have to use a custom S+ module to handle this is absolutely ridiculous - the TCP Client is a native hardware device symbol...
What experiences have other had about this??


Re: DM-PSU-3X8-RPS is Discontinued

 

¿ªÔÆÌåÓý

It¡¯s not as elegant (or rack mountable) but I think some multiple of PW-5430DUS is your answer

?

?

?

--

Lincoln King-Cliby, CTS, DMC-E-4K/T/D
Commercial Market Director
Sr. Systems Architect | Crestron Certified Master Programmer (Diamond)
ControlWorks Consulting, LLC
Direct: (+1)440.771.4807 | Cleveland: (+1)440.449.1100? | Boston: (+1)508.695.0188 | DC: (+1)202.381.9070? | Fax: (+1)440.449.1106
Crestron Services Provider | Biamp Authorized Independent Programmers | Extron Qualified Independent Programmer

?

From: [email protected] [mailto:[email protected]] On Behalf Of jrw_96 via groups.io
Sent: Friday, April 08, 2022 2:34 PM
To: [email protected]
Subject: [crestron] DM-PSU-3X8-RPS is Discontinued

?

Anyone have any suggestions for a replacement device that will supply PoDM+ power to all ports on a 64x64 blade?

Are we out of luck and stuck powering everything with wall warts?

-JRW


DM-PSU-3X8-RPS is Discontinued

 

Anyone have any suggestions for a replacement device that will supply PoDM+ power to all ports on a 64x64 blade?

Are we out of luck and stuck powering everything with wall warts?

-JRW


bosch dcn ccub-ul

 

Hi All,

Does anyone know where I can find configuration software for this unit? (bosch dcn ccub-ul)

Thank you


Re: QSYS with Mat Klucznyk Github

 

Scott,

I am currently using these module without any issues.
Can you post a snippet of the Fader (one with issues) and Core module?


Re: Calling a C# method from Simpl+

 

Thanks for the response and I was able to get this to work.?
Next: I am reading an XML document, converting to JSON (this works) and placing in a <List> but not certain how to get the list back to Simpl+.


Re: Control for NP-PA803UL / new protocol?

 

¿ªÔÆÌåÓý

I don¡¯t think 015. Power On is the actual command just the command number and name (if you look at other fields in the document there are hex bytes provided for e.g. DATA 02 and DATA 03. I think you¡¯re missing the actual protocol document.

?

See page 190 of for (a portion of) the protocol where power on = \x02\x00\x00\x00\x00\x02.

?

I¡¯ve been able to throw more or less the same commands at every NEC projector I¡¯ve seen in the past 12ish years. Incidentally there was a run of NEC projectors that would randomly lock up the COM ports at 38400 (or maybe at 38400 + DM); setting the baud to 9600 resolved that issue so more or less out of superstition I¡¯ll always set a NEC projector to 9600 rather than leaving it at 38400 .

?

--

Lincoln King-Cliby, CTS, DMC-E-4K/T/D
Commercial Market Director
Sr. Systems Architect | Crestron Certified Master Programmer (Diamond)
ControlWorks Consulting, LLC
Direct: (+1)440.771.4807 | Cleveland: (+1)440.449.1100? | Boston: (+1)508.695.0188 | DC: (+1)202.381.9070? | Fax: (+1)440.449.1106
Crestron Services Provider | Biamp Authorized Independent Programmers | Extron Qualified Independent Programmer

?

From: [email protected] [mailto:[email protected]] On Behalf Of Tray Schaeffer
Sent: Friday, April 08, 2022 8:48 AM
To: [email protected]
Subject: [crestron] Control for NP-PA803UL / new protocol?

?

All,?

Working with new laser projectors here at a job site.? Set the PC cotnrol within the projector to 38400.?
Unfortunately, control via HDBaseT is not available due to the way things are wired.?
These are connected to DM-RMC-200 receivers from DM 32x32 (not CPU3).?
DM endpoints reports on line but have no comms at all with projector. Stereo mini is connected to the PC Control input on display, not the IR remote input next to it.?

Anyway, Seems that the control protocol may have changed since I last worked with one of these.?

See this document.?

?

?

The NP-PA803UL is listed.?

Not sure if the command should include the preceding number or not..?

From the document, power on = "015. POWER ON". Not sure of terminating char, if any is required.?

?

Any experience with these??

Thanks in advance,?


Tray


Re: NVX vs. SVSI

 

¿ªÔÆÌåÓý

Hi again Jeff,

?

Sorry for the delayed response, it¡¯s been a busy week.? Here are the answers to your follow-up questions:

  • Does the current VLAN switching software allow for control of multiple switches or just a "switch stack" or "virtual switch"?

You can do VLAN switching either way.? Some installers like the STACK approach when using multiple switches, but it is not mandatory.? This has been true since we launched HDMI over IP in 2008.? The turnkey drivers we came out with in 2010 were based on a STACK implementation, but it has always possible for a knowledgeable control system programmer to manage the switching on independent switches.

  • I'm curious how switching via VLANs is faster than multicast switching for the same product? When we switch streams to a decoder, the majority of latency to "picture" is the decoder processing time for the new stream...shouldn't make a difference if it's a new stream due to switching VLANs or switching routing. In both cases it's a new stream being directed to the encoder. This is borne out by the fact that if we have an incorrectly assigned VLAN for a decoder (i.e. on our control VLAN vice the streaming video VLAN), when we correct the VLAN assignment the decoder still takes the same amount of time to process the new incoming signal to show on the display. I could see mulit-milli-second delay differences in VLAN vs multicast routing, but multi-second has more to do with the decoder than VLAN vs Multicast switching.

In a nutshell, using the VLAN approach we have eliminated the TCP handshake that happens when a multicast device switches to a new stream.? The result is instant seamless switching vs the pause or blank screen associated with multicast switching.

Ed Qualls

Chief Executive Officer

+1-727-475-7033

ed@...

?

?


Re: Crestron Processor with 3rd Party Touch Panel?

 

If you can made custom HTML5 user interfaces on it, our WebSockets suite would be perfect for this application:?https://controlconcepts.net/product/cci_websocket_server_lite/


Re: Control for NP-PA803UL / new protocol?

 

I believe with those you have to go into the settings and manually select which port ( HDBaseT or RS-232 ) is being used for control. Is there network to it? I believe it is Crestron/RoomView connected so you can control it over the network.


Control for NP-PA803UL / new protocol?

 

All,?

Working with new laser projectors here at a job site.? Set the PC cotnrol within the projector to 38400.?
Unfortunately, control via HDBaseT is not available due to the way things are wired.?
These are connected to DM-RMC-200 receivers from DM 32x32 (not CPU3).?
DM endpoints reports on line but have no comms at all with projector. Stereo mini is connected to the PC Control input on display, not the IR remote input next to it.?

Anyway, Seems that the control protocol may have changed since I last worked with one of these.?
See this document.?
?
https://assets.sharpnecdisplays.us/documents/miscellaneous/pj-control-command-appendixes.pdf
?
The NP-PA803UL is listed.?
Not sure if the command should include the preceding number or not..?
From the document, power on = "015. POWER ON". Not sure of terminating char, if any is required.?
?
Any experience with these??
Thanks in advance,?


Tray


Bathroom/Spa Integration Options

 

Hi All,
I have a client that is interested in renovating an bathroom to be an integrated "Spa-Like" experience.
Looking for things like Steam Shower control, Shower control, Floor heating control, etc.
What have others found that works well in a Crestron-integrated situation (SMW of course!)

TIA!


Re: HZ-THSTAT

 

Has anyone actually installed any of these recently??? (I know, I know...has anyone actually received any of these recently???)

If so, Has the issue with unreliable room temp readings been resolved yet??

TIA!


Re: Crestron Processor with 3rd Party Touch Panel?

 

Haven't used this before...

It would need some research as I've never even heard of it before either


Re: Crestron Processor with 3rd Party Touch Panel?

 

What about node-red and http control as a solution

On Thu, Apr 7, 2022 at 9:18 AM Audvizer <Audvizer@...> wrote:
Hi Zac,

Yes we have installed one these before.?

Sadly the client wants to use the equipment he already has if he can


Re: Crestron Processor with 3rd Party Touch Panel?

 

Hi Zac,

Yes we have installed one these before.?

Sadly the client wants to use the equipment he already has if he can


Re: Crestron Processor with 3rd Party Touch Panel?

 

If this is MTR setup, you can make it work if you have/add Q-SYS DSP.?