Re: Using a 2-series processor for KNX module development
#crestron
We want to establish control and feedback of a VIMAR system (lighting and HVAC to start), which we believe is straight KNX communication but with some trickery in its addressing portion.
The thing is, VIMAR actually discourages 3rd party integration of their systems, so we would be working on our own. The emphasis on the 2 series processor is because we can actually get our hands on a decommisioned CP2E (or AV2 with Ethernet card) since all of our 3 series processors are already on their respective job sites getting set up and programmed. If we get this done, we would start offering this integration to our clients immediately (with brand new 3 series processors of course). At the moment this is just a fun little side project to see if its possible (but with the potential to reap some serious benefits since VIMAR has a big presence in the EU and most of Latin America). |
Re: Using a 2-series processor for KNX module development
#crestron
What do you want to develop exactly? There are 2-Series modules for the CI-KNX:?
You can also have Smart Graphics on a 2-Series but no Applications, one some not even Smart Objects, see? for details. With 3-Series you gain performance and also the ability to use the latest modules for the CI-KNX which make use of SIMPL#. |
Re: NVX and DANTE on Cisco 2960-x Switches
With enterprise level switches, it's best to setup QoS for Dante when on the same VLAN as other multicast traffic like NVX. And with Catalysts, NVX will work without unregistered filtering enabled as the querier and mrouter autolearn functionalities are much more robust than Pakedge (Pakedge is horrible for things like NVX) but you can still enable it with the command switchport block multicast which is applied on a port basis so youd want to do int range gi x/x/x-x but that will affect pulling up device settings in Dante Controller as Dante traffic is seen as unregistered multicast.
|
Using a 2-series processor for KNX module development
#crestron
Hello, good morning guys.
For my next personal project I want to develop a KNX module for a possible future integration job with a VIMAR system (lighting, HVAC, etc). Would it be possible to use a 2 series processor for this integration? what would I be missing compared vs a 3 series processor? is the main thing Smart Graphics? I used an RMC3 for the development of my Bticino MyHome module, and it performed very admirably. How would a decommissioned?AV2 (with an ethernet card) or an CP2E perform compared to the RMC3? Thanks! EDIT: The KNX interface is the CI-KNX. |
Topics in Home Automation - New Article Published in Residential Tech Today Magazine
My latest article, "Landroid, Tertill, and Rachio: A Smarter Way to Take Care of a Yard¡± is being published by the good folks at Residential Tech Today Magazine on their web site.? With summer upon us, this article looks at technology that at can minimize the drudgery of yard work including mowing, weeding, and watering.?? You can find the full article here:? For those interested in earlier articles that I've written, you can find those here: For those interested in even earlier content I've written, you can find my blog here: I hope you find the information useful. Thanks |
File /IR Drivers//HisenseTV.ir uploaded
#file-notice
[email protected] Notification
Hello, This is a notification to let you know that the following files have been uploaded to the Files area of the [email protected] group. Uploaded By: Dustin Wenninger <dustinwenninger@...> Description: Cheers, |
Re: Program Restart.
#console
Progreset -p:1 can be used for IPtable addpeer commands for remapping IPIDs for example.
|
Re: Samsung Flip2
Ok Thanks. Seems like samsung has not publiced API yet On Wed, Jun 24, 2020 at 08:34 TBB Automacao <tbbautomacao@...> wrote:
|
Re: Samsung Flip2
Hi Quang, No I don't have any control by Lan or RS.? On datasheet, I form control by RS and Ethernet. But I don't have success.? Only using CEC. But I don't like so much. I Prefer by Lan.?
|
Re: Samsung Flip2
Hello TBB, Do you have any luck on controlling these units via RS232 or LAN? I searched a lots but it seems there is no commands list in their documentation. Regards, V¨¤o Th 3, 23 thg 6, 2020 va?o lu?c 08:13 TBB Automacao <tbbautomacao@...> ?? vi?t:
|
Re: TSW-x52 non Crestron mac address
Thanks for the help guys. I ended up finding a handy python script on github that let me figure out the sudo password. |
Re: NVX and DANTE on Cisco 2960-x Switches
I had this exact issue using that pakedge switch? a while back.? Ended up buying a Cisco 350x and still had the same problem.? Finally figured it out after a number of headache filled days.??
Do you have unregistered multicast filtering enabled?? If NVX is working you probably do.? That setting will break Dante so you need to forward on some specific multicast addresses to the Dante device ports.?
|