Re: Does anyone know of any IP modules for a 2014 Samsung UN series TV?
I do have the protocol for RS-232 via the mini jack service port. The module is written for URC Total Control but I can post a picture of the commands if you like. You do need a TTL converter for the service port. I used a B&B electronics 232LPTTL but I cant remember if its the 3.3 or 5v version. I thinks its the 33 (3.3v) version. The model I tested was Samsung ED55D. |
Re: VT project for ipad mini 4
¿ªÔÆÌåÓýUsed to be that way.? Not anymore and it is pretty easy to download the wrong one. ? Adam Zatorski King Systems LLC ? From: Crestron@... <Crestron@...>
Sent: January 24, 2019 10:59 AM To: Crestron@... Subject: [Crestron] Re: VT project for ipad mini 4 ? ? I always thought the crestron app on ipad only see it for the ipad and vise versa. I think used to be that way. ? Thank you I will check on that.
|
Crestron DSP 1283 and MXA910
Dear all,
Have anybody used DSP 1283 with SHURE MXA910, I need help on AEC control. For your information I had used the Shure MXA 910 9th cahnnel as it is the Auto Mix channel and routed it to DSP1283 1st channel only, I know that I had to route the far end audio to AEC reference in Crestron DSP but don't know how to do that . Somebody please help me with a snapshot or sample program for this. |
Re: VT project for ipad mini 4
I had this happen a few months ago, and it was because the client had mistakenly installed the iPhone app on one of the iPads.
toggle quoted message
Show quoted text
--- On Thursday, January 24, 2019 at 10:39 AM, johnny.cashav wrote: |
Re: MC3 Image
Were you able to find a copy? On Thursday, January 17, 2019 jeroen.vandervelden <Crestron@...> wrote:
?
Hi, Im looking for an MC3 Image file. I found bunch of Reddit and Yahoo topics but no links in it. Does anyone has the image? Br, Jeroen |
Re: Infratech heater - 0-10v range to use?
I worked on a project with a few of these a couple of years ago. I didn't perform any scientific testing, but there was definitely a difference between say 30%, 60%, and 100%. It wasn't very noticeable between smaller increments, so I simply gave them "High", "Medium", "Low", and "Off" settings. I don't remember the exact model of Infratech heaters they had, or if that makes a difference.
toggle quoted message
Show quoted text
--- On Wednesday, January 23, 2019 at 2:20 PM, Jon wrote: |
Re: Cisco SX80 and Touch 10 Communication with Crestron DMPS3-200-C
You just need to create the GUi, and load to the codec. You can give your own name to each control, or use the default assigned when you create the control. In the program, use the cisco touch 10 modules, one for each control.(there is one for each type of control you can create) Put the name of the control widget from the gui editor in the paramWidgetId field, and tie all the modules to the control processor module, then send to the codec via your serial or SSH connection - initialize the control processor module after codec or processor reboot, and that should be all you need to do. |
Infratech heater - 0-10v range to use?
Hi all, We have a house with 6 heaters and they say the range isn't really working, the heaters are really just on or off. I tried using like 10%, 20%, 30%, 40%,50%,60%, 70%, 80%, 90%, 100%. But I am being told that the heat is more like a switch and just really either on or off. Has someone worked with these and figured out a curve that I can scale to such a like 66% is min and 90% is max kind of thing? I know it all varies but how many heaters, how high up they are mounted, the model, etv. But?wondered if someone has experienced this and has any tips. Thanks! Jon? |
Re: Steamist Sauna Control
Does anyone had any idea?
On Monday, January 21, 2019, 5:15:46 PM EST, johnny.cashav@... [Crestron] wrote:
?
Hi everyone Does anyone have a module that can control this device? I was using the one in the application market but they have changed the ports to udp 30303 and the olde one is 9761 and theres no way to change that. Any help is appreciated. Thank you |
Re: Cisco SX80 and Touch 10 Communication with Crestron DMPS3-200-C
Hi, Thanks for your reply, but do I need to do certain codeing in cicso VC or making the GUI using cisco end room controller is enough.
|