¿ªÔÆÌåÓý

ctrl + shift + ? for shortcuts
© 2025 Groups.io
Date

Re: DMX interface?

 

"So, what is the most cost effective, reliable way to communicate with a device that takes DMX cues?"

I have - but haven't played with it much yet - the KissBox DMX interface - might be worth checking out.? Have it controlling a multicolor, multisegment LED bar currently.? Personal thing, so - haven't had as much time as I wish.

? - Chip


Re: Single button dimmer

 

I made that module but I guess I'm having a hard time understanding. The module has a single analog output that connects to the dimmer device. So it would seem that because there is only one analog signal, the lights must necessarily follow it. Maybe you are using two of the onebutton modules, driven by a single button? If you have a reason to do that, then I suppose that adding additional logic as you have done is a good approach.

On Tue, Feb 23, 2016 at 4:56 AM, upag2016@... [Crestron] <Crestron@...> wrote:
?

Hi everyone, I'm using in my project the "Dimmer?ramp & presets for single button light control

jasonwmelvin?May 22, 2010" macro downloaded from this group.
Everything is fine but when I'm using it for a group of two ballast and one of the is off (es. when with a panel slider I get it off) if I press the ON/OFF single button, one ballast is going on and viceversa for the other.
This is my solution for this issue:
I've inserted a True table that checks if the couple of ballast are on or off it works as an usual on/off function an if one of the two ballasts is on it sends a 0d analog signal to the corresponding input DIN DALI ballast level...

I'm right? Any suggestion to make it easier!

Thank's Ugo Pagotto (Italy)

Apologizin' for my poor English...?

?



Single button dimmer

 

Hi everyone, I'm using in my project the "Dimmer?ramp & presets for single button light control

jasonwmelvin?May 22, 2010" macro downloaded from this group.
Everything is fine but when I'm using it for a group of two ballast and one of the is off (es. when with a panel slider I get it off) if I press the ON/OFF single button, one ballast is going on and viceversa for the other.
This is my solution for this issue:
I've inserted a True table that checks if the couple of ballast are on or off it works as an usual on/off function an if one of the two ballasts is on it sends a 0d analog signal to the corresponding input DIN DALI ballast level...

I'm right? Any suggestion to make it easier!

Thank's Ugo Pagotto (Italy)

Apologizin' for my poor English...?

?


Re: S+ Basic Question

 

Nathan - I'm reading in a setup file. Initializing labels and icons and setting visibility of specific media for a given room based on input from the file. I'm working on an S+ module to do it. Do you think that's doable as a Simpl Windows Module?


Re: Sony SRG-300H Camer over IP control.

 

Hi sopheap ouk,the module works very well, thanks for your help. Your are legend!!!^^


Re: Adding a new device to a project

Heather Baiman
 

Your module will only appear in the Symbol Library. The PRO2 has six built in COM ports. Pick one and connect the RX$ and TX$ from your module that you 'drag' from the Symbol Library into the Program View Logic folder.



From: Crestron@... [Crestron@...]
Sent: Monday, February 22, 2016 7:07 PM
To: Crestron@...
Subject: [Crestron] Re: Adding a new device to a project



Putting it in the same directory as the project gets it added to the symbol library, but I still don't see it in the device library to assign to a serial port on the Pro2.
- Dave





============================================================================
Please refer to
for important disclosures regarding this electronic communication.
============================================================================


Re: Adding a new device to a project

 

Putting it in the same directory as the project gets it added to the symbol library, but I still don't see it in the device library to assign to a serial port on the Pro2.
?- Dave


DMX interface?

 

So, what is the most cost effective, reliable way to communicate with a device that takes DMX cues? (CP3 processor)


Thanks;


Kol


Re: Sonance DSP series amps

 

I've used these as replacements for the old 875's. ?We didn't use the preamp functions or the IP control, just the DSP for setup, and we triggered them on and off. ?They mostly work well, but I had a couple of frightening freakouts where the sound came out all crazy and distorted until I power cycled. ?Only happened 2 times, but enough to worry me. ?After that, we just disconnected the Enet feed from them during normal operation. ?The DSP setup was very similar to the Sonnex tool, with crossovers, and custom EQ for all of the Sonance speakers.


Re: Cisco Stadium Vision & Crestron control

 

have you guys had any luck with this thing? Im working with this and with appSpace embedded in it. looking for "simple" ch+ ch- controls.

thanks,
Andrew


AAS shows OFFLINE in AV2 IP table

 

So, my AAS-2 shows in the IP table of the AV2 Status OFFLINE. I'm very uncertain about the right settings.


Router: ?192.168.1.1

AV2: ? ? ? 192.168.1.2

AES: ? ? ? 192.168.1.3 ?(SIMPL WIN: IPID 20, Default-Address 127.0.0.1

AAS: ? ? ? 192.168.1.4 ?(SIMPL WIN: IPID 21, DefaultAddress ?127.0.0.1


TOOLBOX AV2

IPID 21 Address 127.0.0.1 slave 00 41974 gway offline


TOOLBOX AES IP-Table

IP ID 21 Address 192.168.1.4, EntryType = slave, DEVID = 0, Port 41194 Status Offline


In the AES-Ethernet-Config , is Router and DNS my Router( 192.168.1.1) or the AV2 (192.168.1.2) ??

Same question about AAS-Ethernet: Router or AV2 as Router and DNS


I can access the AAS Gui if i type the IP into the browsers adressfield.


Hopefully someone can show me the way, thanks in advance!!





Re: OSC Protocol - Website Down

 

I suggest trying the wayback machine at archive.org


OSC Protocol - Website Down

 

Does anyone have a copy of the OSC protocol standards? I have a project coming up that leans heavily on this and the website has been down for at least a week now. I've been looking around the net but just finding bits and pieces so I figured maybe someone on here has a full copy laying around?

?(currently down along with the entire site)

Thanks in advance!

Dustin



Re: S+ Basic Question

 

"some of the complex logic either takes 30 steps in Simpl or can't be done at all (at least not by me) and I can get it done with 5 lines of S+ code. Those are the circumstances I will revert to S+."

Here's the thing with that though, you're invoking a task switch each time you leave Simpl to do something in S+. If you're on 3-series processors, it's harder to tell because they're so much faster, but if you're on a 2-series processor you really need to find a good justification as to why you should jump out to S+. 30 steps in Simpl is not a big deal, particularly when dealing with a fast changing analog or serial.

On Mon, Feb 22, 2016 at 6:11 AM cfm@... [Crestron] <Crestron@...> wrote:

"This should help explain it. :)"

Nope - totally lost now.

? - Chip


Re: pyng wired devices

 

I talked to true blue about this as I wasnt sure if 200 was the max for infinet ex with expanders or if it was max total including wired devices. They told me that 200 was indeed the max for ALL devices both wireless and wired, this is the max the processor can handle, they also told me this isnt a hard cut off thats just what they guarantee. for instance if you had 210 devices it would most likely still work fine.


Re: Recalling Presets on an Allen and Heath QU-16

 

tcp ip client to port 51325

\xB0\X00\X00\XB0\X20\X00\XC0\X00 preset 1


Re: S+ Basic Question

 

"This should help explain it. :)"

Nope - totally lost now.

? - Chip


Re: pyng wired devices

 

If I remember correctly, the max is 200 devices.


pyng wired devices

 

what's the maximum number of wired devices (keypads, DIN RAIL, etc) PYNG can handle?


Re: Windows 10 indexing error?

 

I found this, it helped with my system when it was taking ages to create a new folder. It may help with this problem??

  1. Unless you want to do a fresh install of Windows then it will clear up some of your problems. If not, there's a lot of junk that was carried over from the previous Windows. One of them is Windows.edb (Search index database). Open the services, temporarily disable Windows Search service. Turn on the folder options to show hidden files and navigate to:
    C:\ProgramData\Microsoft\Search\Data\Applications\Windows and delete Windows.edb
    Go back to services and re-enable Windows Search to automatic and let Windows rebuild the search index database

?