Keyboard Shortcuts
Likes
- Crestron
- Messages
Search
DMPS Video Lag
I have a DMPS-200 installed with a local PC going into one of the HDMI inputs and out of the DM output to a DM-RMC-SCALER to a 70 inch display. The customer is using the 70 inch display as their local monitor and is saying there is lag in the mouse when working. I have noticed the lag (mili-seconds) and TB claims this is normal video processing and no settings will correct the lag. Maximum cable run is probably 75' of DM cable. Has anyone seen this before or know of a setting that might correct the lag?? Just trying to explore options. Thanks |
Re: Divisible Room GUI
I use two overlapping circles like a venn diagram for a combing icon.? Like this one: On Wed, Oct 1, 2014 at 10:35 AM, bdige@... [Crestron] <Crestron@...> wrote:
|
Re: New DSP
¿ªÔÆÌåÓýDitto on the Nexia/Audia.? Tesira is the same concept except you get to create your own subscription name for feedback :).? On Oct 1, 2014, at 1:00 PM, Andrew Welker andrew.welker@... [Crestron] <Crestron@...> wrote:
|
Re: D3 : Conditional logic for HRV bathroom fan controlled from multiple rooms
toggle quoted message
Show quoted text
On Oct 1, 2014, at 1:02 PM, easton.altree@... [Crestron] <Crestron@...> wrote:
|
Re: Divisible Room GUI
toggle quoted message
Show quoted text
On Oct 1, 2014, at 1:23 PM, Jeremy Weatherford jweather@... [Crestron] <Crestron@...> wrote:
|
Re: Divisible Room GUI
Some people, when confronted with a problem, think "I know, I'll use crosspoints."? Now they have two problems. Just kidding... sort of.? Stolen from jwz. On Wed, Oct 1, 2014 at 2:39 PM, cyberbri24@... [Crestron] <Crestron@...> wrote:
--
Jeremy Weatherford |
Re: New DSP
Andrew Welker
Just use Instance ID Tags instead of the DSP assigned tags. Then as long as the control gets the correct instance ID tag, then it'll work no matter what the instance ID is. I don't remember the last time I used the assigned instance id. On Wed, Oct 1, 2014 at 2:53 PM, cyberbri24@... [Crestron] <Crestron@...> wrote:
--
In Him, Andrew Welker |
Re: AV2 and Rack2
Use the AV2 as the master, then drop a RACK2 in your crestnet devices as a Crestnet slave since you have no E-NET card. In the Rack2 info view in toolbox, you'll see where it has a Crestnet ID of "2". You need to change that to some other Crestnet ID (3 or higher) and it will show up on your AV2 crestnet network.
Goodluck, Cyberbri |
Re: New DSP
I Like Biamp for its customization, Have yet to use the Forte but like the idea of the USB for the capability for adding Skype/Lync.... Hate how the instance ID can be lost if a tech deletes a control, then adds it back.
I Like Polycom SS, never had any issues. I Love Clearone, from a control standpoint. Its nice to get realtime feedback and if you use Macros for control, it can be a rock solid solution. Just deployed about 50 of these in the summer with no issues or calls. Techs can go in after and tweak input/output/mixer levels and adjust a macro for even more control and it never effects the integrated controls. I actually have a standard DSP that can be loaded into a 840T and 880T. Started using Processing buss A, B, C, & D, Faders 1, 2, 3, & 4. This way if the job has a need for more than 8 sets of controls or levels to be tracked, I have the engineer make sure the system adds the 880T which allows for more processing. ? |
Re: Divisible Room GUI
It's "just like that other divisible room". On Wed, Oct 1, 2014 at 2:22 PM, Lincoln King-Cliby lincoln@... [Crestron] <Crestron@...> wrote:
|
Re: Divisible Room GUI
¿ªÔÆÌåÓýThere is a standard¡every one is a little different. ? -- Lincoln King-Cliby, CTS, DMC-E-4K/T/D Commercial Market Director Sr. Systems Architect | Crestron Certified Master Programmer (Gold) ControlWorks Consulting, LLC V: 440.449.1100 x1107 F: 440-449-1106 I: Crestron Services Provider | Biamp Audia Certified | Extron Control Professional ? From: Crestron@... [mailto:Crestron@...]
Sent: Wednesday, October 01, 2014 12:10 PM To: crestron Subject: Re: [Crestron] Divisible Room GUI ? Sorry no, but I'm still laughing at the words "standard divisible room" being used consecutively.... ? On Wed, Oct 1, 2014 at 9:35 AM, bdige@... [Crestron] <Crestron@...> wrote:
|
Sony evi-d camera processor
So I was working with a VDO360 camera last week. There is a published crestron module on their website that I tried to use-It did not work well and zoom in and out did not work at all. So tried a different sony module (it uses sony visca protocol) the zoom also did not work on that module.I modified the module allowing for simple zoom in and out cause I had a lot of stuff to do as the install was out of the country and time was limited. When I got back I dug in a little bit and found that for zoom in and out the strings being sent to the cam for zoom were wrong good example \x81\x01\x04\x07\x02\xFF this would indeed zoom in bad string from modules??\x81\x01\x04\x07$\xFF? ? so for that last hex the module spits out ascii it looks to me like the problem lies in the simpl+ module "sony EVI-D camera processor" ?all the modules including the published vdo360 have this simpl+ in common has anyone encountered this before? maybe some simpl+ gurus can see why this happens. I believe it occurs in the zoom speed section of the processor but it is not obvious to me where the error lies |
Re: Controlling Nuvo P3500 with Crestron
If it's like the wireless streamers the line input just shows up in the browse list, On Tue, Sep 30, 2014 at 8:14 AM, bradwykoff@... [Crestron] <Crestron@...> wrote:
--
G Miller G Miller Designs and IntegrationPros (314) 550-2566 Skype: cidocs ![]() ![]() |
Re: Divisible Room GUI
Sorry no, but I'm still laughing at the words "standard divisible room" being used consecutively.... On Wed, Oct 1, 2014 at 9:35 AM, bdige@... [Crestron] <Crestron@...> wrote:
|