Re: TPMC-9 crash issue

 

I didn't notice your response Henry (been very busy), but I came back here to update the thread with some new information.

All my panels are on Ethernet. I disabled cresnet (out of pure desperation), and voila, since then I have not seen it happen. It could still be occuring, but anecdotally a lot less frequent.

So if anyone else is experiencing this, you might want to try the same.

cheers,
-noob

--- In Crestron@..., "Henry" <henryelykyburg@...> wrote:

I have 16 of these things and 3 of them are (consistently over a period of days) randomly rebooting. I'm pretty sure I have seen it on more than these three, but for now we have identified 3 panels where the behavior is common enough to cause a problem.
Behavior: Panel reboots upon a button press, or panel reboots for no reason at all.
Mine are all Cresnet connected, some powered locally, most powered by Cresnet with power calculations done.

Thanks for all your replies.


--- In Crestron@..., "Crestron Noob" <crestronoob@> wrote:

I'm not sure if you are really the unfortunate one, I mean since it didn't happen to you and all ;-)
-noob
--- In Crestron@..., "eagrubbs" <eagrubbs@> wrote:

Wow. I, unfortunately, have done tons of these panels and not had this happen. I wonder what is different, or is it just that my time is coming.

--- In Crestron@..., "Crestron Noob" <crestronoob@> wrote:

I'm now 100% convinced this is an OS/firmware issue. Happened on two brand new panels today that have never had a program loaded (only updates). Exactly the same behavior as described below, crashed while working in setup. Guess I'll report it.
-noob

--- In Crestron@..., "Stig" <ska@> wrote:

I would also check for:

Scandinavian characters(special) in graphic files or page names - insufficient power.

-Stig

--- In Crestron@..., "Crestron Noob" wrote:

Thanks for your responses. I use only alphanumeric characters in file names, as I have been burned by this before. I just checked every single one to be sure ;-)

Also I have done the initialize/restore and clean compiles. I will try the remaining suggestions to be safe.

To be clear, the panel can stay functional for hours, even days with all the buttons working, before this happens at random. Sometimes it happens with relatively short interval, like 15 minutes, but usually not.

I am deploying to 10 systems, so I guess I?ll find out if it is a bad panel soon enough..
-noob

--- In Crestron@..., Robert Parker wrote:

There another thread recently about unsupported characters in graphics file
names. I had a project with a TPMC-9 that experienced this. The panel would
work, freeze, reboot, work. It's just a thought but worth checking.
No rhyme or reason. I found it by deleting pages until the problem went
away. Can you load a simple 2 page, 2 button project where the buttons just
cause a page flip to the other page and see if it still has the problem?
(No graphics loaded)

YMMV

On Fri, Jan 25, 2013 at 3:47 AM, Crestron Noob wrote:

**


I'm experiencing weird crashes with TPMC-9 (OS 3.001.0052, FW 2.11.0039)

Panel dims way before the standby timeout (1 - 15 seconds after a button
press). If I touch it, the picture comes back, only to dim down again
literally the next second. Repeat a few times, then it reboots. Comes back
up as if nothing had happened.

The only message I could find in logs was "render timeout", I'm not sure
it's related at all. Core2 project with a CP2e.

Any ideas?

Thanks
-noob



[Non-text portions of this message have been removed]


Re: Lutron QS Request Command <--Please someone help!!

 

I am glad to get kind reply from you.
OK,,, i will try with "?OUTPUT,ALL_DEVICES,1"

Do you know what's the meaning of the last "1"
According to the manual, it says "Action Number"
I can't understand...

--- In Crestron@..., Eric Williams <ewilliams0305@...> wrote:

Its been a while but instead of "1" try the commands using "ALL_DEVICES" as your integration Id. It will definitely work for polling not sure about setting levels.

-----Original Message-----
From: "sevenstarokawari" <tabata@...>
Sent: ?€&#65533;3/?€&#65533;21/?€&#65533;2013 9:09 PM
To: "Crestron@..." <Crestron@...>
Subject: [Crestron] Re: Lutron QS Request Command <--Please someone help!!




--- In Crestron@..., "sevenstarokawari" <tabata@> wrote:

Would someone advise me the command to get all zone's brightness of Lutron QS simultaneously?
Actually I sent"?OUTPUT,1,1<CR><LF>", but nothing happens.
The Lutron QS ID of mine is "1"


Regards,



[Non-text portions of this message have been removed]


ONVIF IP Camera Control command format help

maheksamani
 

Hello All,

I was wondering if someone who had already worked with the PTZ IP Camera
with ONVIF protocol.

could you please guide me with the how to control the camera from the
touch panel.


I am Able to stream the camera feed with MJPEG. but need to control the
camera moves.

Thanks a Zillion in advance .

-Mahek


Re: Looking for Leads on a New Gig

 

No thanks needed brother as it was honest and from the heart.

JRW

--- In Crestron@..., "erikm_101" <erikm101@...> wrote:

Thanks.

--- In Crestron@..., "jrw_96" <jrw_96@> wrote:



--- In Crestron@..., "erikm_101" <erikm101@> wrote:

Hello Group,

I find myself thrust into the unfortunate state of no income stream :(

So, I am looking for a new gig. If anyone knows of an available position, please let me know. I am currently looking in the Seattle, Denver or Dallas areas, but will consider other locations as well.

Me: Silver Master (Gold after one more Masters class), AMX ACE Design/Programming (expired) with 20+ years in Crestron & AMX programming in commercial and residential markets.

Any leads would be greatly appreciated.

erik
I don't have a job to offer but I wish you and yours the very best in these times of tribulations...

JRW


Recover .vtz file from MTX3/PTX3, possible?

 

Hi all,

I have a client that we don't have the code for that ruined their PTX3 remote. I think I can still connect with toolbox, but is there a way to get the compiled file out of it to load to a new remote?

WE don't have the VTP to recompile and do not want to change anything, just replace the remote.

Any ideas about console command to get the file?

I looked at the project tab in toolbox on my own PTX3 and don't see any option for extract or recover. I swear I have seen that option on either processors or other touchpanels.

Any tips or tricks to try to get the compiled code to reload on replacement?

Thanks
Jon


Re: Looking for Leads on a New Gig

 

Thanks.

--- In Crestron@..., "jrw_96" <jrw_96@...> wrote:



--- In Crestron@..., "erikm_101" <erikm101@> wrote:

Hello Group,

I find myself thrust into the unfortunate state of no income stream :(

So, I am looking for a new gig. If anyone knows of an available position, please let me know. I am currently looking in the Seattle, Denver or Dallas areas, but will consider other locations as well.

Me: Silver Master (Gold after one more Masters class), AMX ACE Design/Programming (expired) with 20+ years in Crestron & AMX programming in commercial and residential markets.

Any leads would be greatly appreciated.

erik
I don't have a job to offer but I wish you and yours the very best in these times of tribulations...

JRW


Core 3.......ya

 

Anyone have issues displaying an analog gauge in core 3?

Specifically the analog feedback seems to update slowly. I tested with just an analog ramp and two buttons to ramp up/down. The analog gauge ramps up and down but slowly and keeps ramping visually after I release the buttons.

Same program/ buttons/ analog ramp/ analog gauge - work fine and update correctly on a standard panel / XPanel.


Sean


Re: Looking for Leads on a New Gig

 

--- In Crestron@..., "erikm_101" <erikm101@...> wrote:

Hello Group,

I find myself thrust into the unfortunate state of no income stream :(

So, I am looking for a new gig. If anyone knows of an available position, please let me know. I am currently looking in the Seattle, Denver or Dallas areas, but will consider other locations as well.

Me: Silver Master (Gold after one more Masters class), AMX ACE Design/Programming (expired) with 20+ years in Crestron & AMX programming in commercial and residential markets.

Any leads would be greatly appreciated.

erik
I don't have a job to offer but I wish you and yours the very best in these times of tribulations...

JRW


Re: subpage z-order ft-tps4

 

Thanks for responding. The changelog for VTPro mentions enabling the z-order features for other panels, so it seems like an oversight to me, like someone forgot to set that flag in the database.

In fact, if I save the project as a TPS4L project, I can set the z-order option, compile, and upload to the FT, and the project works just the way I wanted. Just annoying that I would have to resort to a "hack" like that.

I've emailed TB, see they respond with anything useful.

--- In Crestron@..., "fabiodaubermann" <fdaubermann@...> wrote:


Been there, done that... The flip-top simply doesn't have that option. Which tells me that probably a separate team of engineers worked on the flip top model than the 4L. Other than that, I can't imagine why the hardware would be different between the two models.

Weak...

The last triggered subpage is what always shows up. You will have to do some tricks with delayed pulses or something...
Fabio


--- In Crestron@..., "jaaronart" <jaaron7@> wrote:

Does the flip-top TPS4 not have the option for sub-page z-order? I've always preferred the option for "Follow subpage-reference Z-order" for my projects, so I can always be sure of how the subpages will display. The C2N-FT-TPS4 doesn't have that Compile option, but the TPS4L does.

I can't recall if the option was there before and has disappeared or if I'm just thinking of other touchpanels that I've used.

Can someone confirm if this option was ever available for the ft-tps4?

I just updated everything with Master Installer last night, so I'm wondering if a recent update may have done away with it.


Re: D3 "link" levels between two switches

 

Hi Heath,

It is very easy if you want them to ALWAYS match level. In your trigger for system startup, add a new step and change the type to 'connect'. Supply the slave load current level and the master load current level, set operator to '=' and it is really just that easy.

hth, erik

--- In Crestron@..., Heath Volmer <hvolmer@...> wrote:

Is there any way to make one load's level always match another?

I have a case where a slave switch needs to turn on it's load, as well as an adjacent load. I thought there was a way to say "level1 = level2".

Alternatively, is there a way to somehow respond to the slave button programmatically? I can't see anything, even at the simpl level. Might have to pull this slave out and stick in a keypad or dummy dimmer.

Heath Volmer
Digital Domain Systems
Littleton, CO



[Non-text portions of this message have been removed]


Looking for Leads on a New Gig

 

Hello Group,

I find myself thrust into the unfortunate state of no income stream :(

So, I am looking for a new gig. If anyone knows of an available position, please let me know. I am currently looking in the Seattle, Denver or Dallas areas, but will consider other locations as well.

Me: Silver Master (Gold after one more Masters class), AMX ACE Design/Programming (expired) with 20+ years in Crestron & AMX programming in commercial and residential markets.

Any leads would be greatly appreciated.

erik


Re: Lutron QS Request Command <--Please someone help!!

Eric Williams
 

Its been a while but instead of "1" try the commands using "ALL_DEVICES" as your integration Id. It will definitely work for polling not sure about setting levels.

-----Original Message-----
From: "sevenstarokawari" <tabata@...>
Sent: ?3/?21/?2013 9:09 PM
To: "Crestron@..." <Crestron@...>
Subject: [Crestron] Re: Lutron QS Request Command <--Please someone help!!




--- In Crestron@..., "sevenstarokawari" <tabata@...> wrote:

Would someone advise me the command to get all zone's brightness of Lutron QS simultaneously?
Actually I sent"?OUTPUT,1,1<CR><LF>", but nothing happens.
The Lutron QS ID of mine is "1"


Regards,



[Non-text portions of this message have been removed]


Re: Lutron QS Request Command <--Please someone help!!

 

--- In Crestron@..., "sevenstarokawari" <tabata@...> wrote:

Would someone advise me the command to get all zone's brightness of Lutron QS simultaneously?
Actually I sent"?OUTPUT,1,1<CR><LF>", but nothing happens.
The Lutron QS ID of mine is "1"


Regards,


Re: Infinet EX Switch and 1 HP Motor

 

Pay attention to the minimum load...

JRW

--- In Crestron@..., "jac777888" <jchelton@...> wrote:

Great thats what I though, I knew the RadioRA switches had a minimum load, so wasnt sure if the same applied to the EX switches (first time using them).

--- In Crestron@..., "seb_mtl" <seb514mtl@> wrote:


a switch is a switch

you can control a 120v coil relay who control another bigger relay.

you can control a power plant if you want


just , you need.... neutral ( the white one )





--- In Crestron@..., "jac777888" <jchelton@> wrote:

Hi,

I am trying to control a pool pump motor and notice the size limit for motors for the CLW-SWEX-P is 1/2 HP and pump is 1HP.

My question is has anyone used or forsee any problems using a CLW-SWEX-P to activate a contactor like a Fuji SC-E1 that has a 120V coil?

Thanks


Re: Infinet EX Switch and 1 HP Motor

 

Great thats what I though, I knew the RadioRA switches had a minimum load, so wasnt sure if the same applied to the EX switches (first time using them).

--- In Crestron@..., "seb_mtl" <seb514mtl@...> wrote:


a switch is a switch

you can control a 120v coil relay who control another bigger relay.

you can control a power plant if you want


just , you need.... neutral ( the white one )





--- In Crestron@..., "jac777888" <jchelton@> wrote:

Hi,

I am trying to control a pool pump motor and notice the size limit for motors for the CLW-SWEX-P is 1/2 HP and pump is 1HP.

My question is has anyone used or forsee any problems using a CLW-SWEX-P to activate a contactor like a Fuji SC-E1 that has a 120V coil?

Thanks


Re: Infinet EX Switch and 1 HP Motor

 

a switch is a switch

you can control a 120v coil relay who control another bigger relay.

you can control a power plant if you want


just , you need.... neutral ( the white one )

--- In Crestron@..., "jac777888" <jchelton@...> wrote:

Hi,

I am trying to control a pool pump motor and notice the size limit for motors for the CLW-SWEX-P is 1/2 HP and pump is 1HP.

My question is has anyone used or forsee any problems using a CLW-SWEX-P to activate a contactor like a Fuji SC-E1 that has a 120V coil?

Thanks


Infinet EX Switch and 1 HP Motor

 

Hi,

I am trying to control a pool pump motor and notice the size limit for motors for the CLW-SWEX-P is 1/2 HP and pump is 1HP.

My question is has anyone used or forsee any problems using a CLW-SWEX-P to activate a contactor like a Fuji SC-E1 that has a 120V coil?

Thanks


Re: Bacnet Comms with Honeywell hawk centraline. S/w coach ax

 

since march 3 2013 , the priority is managed in Crestron bacnet subsystem

just tried today with latest database AND cp3
and it's working

--- In Crestron@..., "Alessandro Maldini" <alessandro.maldini@...> wrote:

Hi Matt,
beware of the fact that Crestron processor doesn?€?t handle the ?€?priority array?€? of BACnet IP protocol ; when the processor writes a BACnet object, it always does it with ?€?Priority 1?€? (probably highest than that used by the Honeywell control unit).

Alessandro

From: Neil Dorin
Sent: Thursday, December 13, 2012 2:41 PM
To: Crestron@...
Subject: Re: [Crestron] Bacnet Comms with Honeywell hawk centraline. S/w coach ax


BACnet uses UDP communication so there's no need to specify an IP address.

You'll need to have unique IDs assigned for the Crestron processor and the HVAC device you're talking to. It doesn't matter what ID you use as long as they're separate.

Probably the easiest way to handle HVAC control is to use an analog value to send to the HVAC system to request a set point, then the HVAC programmer supplies you with an analog input (input to his system) that will represent the current temp read by his sensor(s).

This way you only need 2 BACnet points per HVAC zone. Add the two for your processor as a device and his HVAC controller you're at 4 points for a single zone, plus 2 points for each additional. Under 50 points can be done with the free license in a 3-series processor.

-Neil Dorin

Sent from my iPhone

On 2012-12-13, at 1:31 AM, "mattstrads" <mailto:matt.stradling%40dawsonsav.co.uk> wrote:

Has anyone got any experience controlling this system over bacnet?
The hvac programmer hasn't done this before and needs to create backet points according to crestron. How can they do this?

Also in the crestron remote bacnet modules there seems to be nowhere to enter the remote IP address, only the name, id and port. Is this all the crestron needs? We did get some feedback about the remote device.

Any tips would be appreciated
Many thanks

Matt






Nessun virus nel messaggio.
Controllato da AVG - www.avg.com
Versione: 2013.0.2805 / Database dei virus: 2634/5953 - Data di rilascio: 12/12/2012




Re: symetrix jupiter 8 series

 

I made 6 or 7 big restaurants ( 350 people ) with that

what do you want to know ?

--- In Crestron@..., "Daniel Fattorini" <dan@...> wrote:

There's a standard one out there (CresDB I think) but be warned: Symetrix stuff is odd. Last time I did one it had a very strange characteristic. It only responded to serial commands via the 232 port if it was connected to a network via the LAN. Pull out the LAN cable and wham: "err&#92;x0D" to all commands. They said its a bug but a damn nasty one if you ask me. Ended up leaving my cheap 4 port switch in the back of it just to keep it working.

--- In Crestron@..., "raid shamsa" <raidshamsa@> wrote:

hi

does any one have a moduel to control a jupitor syries audio switcher from symetrics. will be willing to pay if need be

thanks




Re: subpage z-order ft-tps4

 

Been there, done that... The flip-top simply doesn't have that option. Which tells me that probably a separate team of engineers worked on the flip top model than the 4L. Other than that, I can't imagine why the hardware would be different between the two models.

Weak...

The last triggered subpage is what always shows up. You will have to do some tricks with delayed pulses or something...
Fabio

--- In Crestron@..., "jaaronart" <jaaron7@...> wrote:

Does the flip-top TPS4 not have the option for sub-page z-order? I've always preferred the option for "Follow subpage-reference Z-order" for my projects, so I can always be sure of how the subpages will display. The C2N-FT-TPS4 doesn't have that Compile option, but the TPS4L does.

I can't recall if the option was there before and has disappeared or if I'm just thinking of other touchpanels that I've used.

Can someone confirm if this option was ever available for the ft-tps4?

I just updated everything with Master Installer last night, so I'm wondering if a recent update may have done away with it.