Re: Crosspoint ECCON on 4-Series


 

¿ªÔÆÌåÓý

The out* is connected to disc_from_e.
That means that is momentarily connected but the normal state would be disconnected. Probably this momentary connection is happening too fast and the resolution of internal logic is that all outputs stay zero. Like driving a digital cue from multiple buffer outputs on the same buffer, with one input being high and the other low; which results in an unexpected result. If the goal is really momentary, then try adjusting the 1d parameter to 1s. If it isn't supposed to be a momentary connection, then you should OUT to disconnect_e and OUT* to connect. Thats how i usually use eccon. So it momentarily disconnects when a analog hits, then reconnects after a time. I usually use a 10d parameter on a sawpulse or 0.2s on an aos.