Thanks I think I have the basic layout. You probably will be hearing from me again.
toggle quoted message
Show quoted text
--- In Crestron@..., Neil Dorin <neildorin@...> wrote:
There should be two layers of crosspoints. One is between the interface
(xpanel) and the audio zone (kitchen). This is driven by audio zone
selection.
The next layer is from the audio zone to the source (Mirage). This is
driven by source selection, after the audio zone has been selected.
Both of these layers are mutually exclusive connections (interlocked) and
are independent of one another. The xpanel can connect to the kitchen,
then select mirage and control the volume of the kitchen zone and the
functions of the Mirage through the kitchen zone. It can also connect to a
different zone and select a different source. The kitchen zone would still
maintain it's connection to the Mirage source.
On Mon, Apr 29, 2013 at 11:19 AM, af8567 <af8567@...> wrote:
**
Let me start by giving Neil much love for the crosspoint flow charts. I
finally feel ready to tackle the topic.
Scenario-
xpanel turn on the kitchen audio zone and control the Mirage server.
My confusion comes in at the point of having the swampe as 1002d and the
mirage as 1001d (connection fed from an init to econn equipment id). How do
I keep the logic (volume up/ down, zone power, music selections) straight
when I have to hit my equipment ID first to make the connection to the
equipment before I let the logic for that device flow. Ie., zone power on,
select mirage, volume...... It feels like I would need a stepper for every
button to make/ switch the connection to the current equipment
respectively? (best practice?) If I hit volume + then every time I would
need to make the equipment id connection first to allow volume + to change
to the sonnex. Thanks in advance for the basic help