Date
Re: MHEARD list
Thanks, John. :-) Best regards. Em s¨¢b., 28 de dez. de 2024, 11:37, John G8BPQ via groups.io <john.wiseman= [email protected]> escreveu:
By Mauro Veiga · #42888 ·
Re: MHEARD list
Yes: *Mheard port* Lists stations heard recently on the specified port. Output can be filtered with a partial callsign, eg MH 2 G8 There are three variants of MH - MHV which lists in a more
By John G8BPQ · #42887 ·
Re: MHEARD list
Ok, John. Is there any command to clear the list? Em s¨¢b., 28 de dez. de 2024, 09:58, John G8BPQ via groups.io <john.wiseman= [email protected]> escreveu:
By Mauro Veiga · #42886 ·
Re: MHEARD list
The list keeps the last 30 entries. If you hear fewer than 30 stations on a port they will stay for ever unless you clear the MH list. 73, John
By John G8BPQ · #42885 ·
Re: MHEARD list
Ok. Thanks, Chuck. 73. Em s¨¢b., 28 de dez. de 2024, 09:05, Chuck Gelm via groups.io <nc8q-aredn= [email protected]> escreveu:
By Mauro Veiga · #42884 ·
Re: MHEARD list
Hi, Mauro: I think MHeard keeps the last 30 forever. IDK. Perhaps it can be only modified in the source. :-| 73, Chuck
By Chuck Gelm · #42883 ·
Re: KA1VSC Packet to shut down
Hi, Matt: Thank you for being a BBS SYSOP. I wish you happiness in this Christmastime and joy in the new year. 73, Chuck
By Chuck Gelm · #42882 ·
Re: Winlink Gateway question
Yes, is my RMS Sysop callsign. I created py1xta-10@... account and aparently solve the problem. Thanks, Jim, John, Mark, Chuck. Em s¨¢b., 28 de dez. de 2024, 05:50, Jim WB9QPM via groups.io
By Mauro Veiga · #42881 ·
Re: ARDOPCF and QtSoundModem?
Jeff You need to point it to the dmix / dsnoop devices not the HW card. They are the virtual cards that can share. 73 Steve [email protected]> wrote:
By Steve G7TAJ · #42880 ·
Re: Winlink Gateway question
Did you request PY1XTA-10 when you sent the authorization to be a gateway? I use the same CMSCALL as I use for WinlinkExpress. Same with CMSPASS and WinlinkExpress password. I¡¯m missing something.
By Jim WB9QPM · #42879 ·
Re: Can't get into my html pages anymore....
Thank you.... that's useful and works slick! Best, j.
By Jerome Schatten · #42878 ·
MHEARD list
Hi folks. How long does Mheard list keep data? Can it be modified? TIA
By Mauro Veiga · #42877 ·
Re: KA1VSC Packet to shut down
We all will be looking for you Matt Be safe and congratulations and thanks being one of us. Hello George Kirn had contact with this data. [email protected]> wrote:
By N9PNO · #42876 ·
KA1VSC Packet to shut down
I hope everyone had a Merry Christmas! I am going to take my system down on or around Feb 1 2025 to prepare for a move. My lease is expiring and we will be moving to Maine temporarily to take care
By Matt KA1VSC <ka1vsc@...> · #42875 ·
Bulletins addressed to non-hierarchical addresses
For clarification the bulletins I am referring to are addressed like the following: @ARL @ARRL @AMSAT @LUNET ...and many others. This is just a note to help sysops new to BPQ understand how
By Mark Taylor · #42874 ·
Re: Can't get into my html pages anymore....
You can also add a LOCALNET=xxxx command to your Telnet port and avoid the user/pass prompts from any computer on the local net. -- 73, Mark, N5MDT Montgomery,
By Mark Taylor · #42873 ·
Re: Winlink Gateway question
I created a PY1XTA-10 email in Winlink and the error message apparently stopped. Em sex., 27 de dez. de 2024, 06:41, Mauro Veiga via groups.io <maurorveiga= [email protected]> escreveu:
By Mauro Veiga · #42872 ·
Re: Winlink Gateway question
Em sex., 27 de dez. de 2024, 04:54, John G8BPQ via groups.io <john.wiseman= [email protected]> escreveu: No. My Winlink address is py1xta@.... PY1XTA-10 is my CMSCALL. What happens if you
By Mauro Veiga · #42871 ·
Re: Winlink Gateway question
Are you saying that your winlink address is py1xta-10@...? What happens if you remove the -10 from CMSCALL? As you have found, your system is working, but it isn't recording any traffic
By John G8BPQ · #42870 ·
Re: Can't get into my html pages anymore....
Thanks Billy.... I just discovered from an older post that I could log into the bpq config pages without a password by going to: 127.0.01:8008 (telnetting in I guess). I then added myself back in as a
By Jerome Schatten · #42869 ·