DR5000 which protocol?


 
Edited

I am currently using a Sprog 3 to control Locos and turnouts (CML DAC20) via JMRI.

?

If I wish to change my controller to a DR5000 and upgrade to block detection later Digitrax BDL168 I would like to know the following:

?

1)???? As the CML DAC20 controls the turnout using track command S1 (Address 45), S2 (Address 46) Thrown/Closed etc. Which connection protocol do I use to send the commands via the Track connection to the CML DAC20 accessory decoder? I am assuming it would be COM(x) Xpressnet protocol. Note: I do not want to use LocoNet at this time.

?

2)???? At a later stage if adding detection using non Digikeijs products does the DR5000 provide LocoNet termination for the BD168 and CML DAC20 plus Railcom RailSync signal for the BDL168?

?

Colin


 

Hi Colin,

I don't know about your other questions, but BDL168 does not support Railcom (BDL168 supports transponding which is different). If you want Railcom you will need Digikeijs DR5088RC

best

Konrad

On Mon, Apr 1, 2019 at 10:06 AM Colin Bennett via Groups.Io <bms.systems=[email protected]> wrote:

I am currently using a Sprog 3 to control Locos and turnouts (CML DAC20) via JMRI.

?

If I wish to change my controller to a DR5000 and upgrade to block detection later Digitrax BDL168 I would like to know the following:

?

1)???? As the CML DAC20 controls the turnout using track command S1 (Address 45), S2 (Address 46) Thrown/Closed etc. Which connection protocol do I use to send the commands via the Track connection to the CML DAC20 accessory decoder? I am assuming it would be COM(x) Xpressnet protocol. Note: I do not want to use LocoNet at this time.

?

2)???? At a later stage if adding detection using non Digikeijs products does the DR5000 provide LocoNet termination for the BD168 and CML DAC20 plus Railcom signal for the BDL168?

?

Colin


 

Sorry all, I should have typed RailSync not railcom!

Colin


 

On Mon, Apr 1, 2019 at 07:06 AM, Colin Bennett wrote:
CML DAC20
Colin,

The DR5000 will terminate the LocoNet.? Both devices will need to be plugged into the LocoNet B for the RailSync.??

Ryan