Re: pseudo
Here is the pure lead xrf..
By
taray singh
·
#1598
·
|
Re: pseudo
Repeated xrf with an almost Pb .
The peaks are almost the same.
The calculation earlier was??on the X-ray goggles which may not??be accurate for escape peak analysis.
Eesc for PbLb1
By
taray singh
·
#1597
·
|
Re: pseudo
Some reference peaks..
By
taray singh
·
#1596
·
|
Re: pseudo
Dude
Pbin- Eesc=Pbesc
Using centroid
PbLb1 :12.62(uncertainty 1.73)
Pbesc : 11.39(uncertainty 18.86)
Eesc =12.62-11.39
?? ? ? ? ? ? ? ??=1.23 keV
Assuming there is Pbesc at left peak
By
taray singh
·
#1595
·
|
Re: pseudo
Taray,
I screwed that up. I looked at the 12.44 keV energy graph line thinking that was the peak energy. So 12.44 – (2* 0.511) = 11.42 keV which coincided with the unknown peak. The actual peak was
By
Dude
·
#1594
·
|
Re: pseudo
DudeCan you elaborate this 2rd ?Pb?escape peak ?Thanks?
By
taray singh
·
#1593
·
|
Re: pseudo
Charles, look at Taray’s spectra using Log Y compared to your Linear Y. If you are looking for small confirming peaks always use a Log Y as its easy to miss things. With all your labels turned on it
By
Dude
·
#1592
·
|
Re: Surma stone
Excellent application of labels!
[email protected]> wrote:
By
Charles David Young
·
#1590
·
|
Re: pseudo
If you wish to mark the escape peak you can create a label by double
clicking one of the seldom used ones. If it is named Pbesc it will show up
with all the other Pb labels when you toggle then
By
Charles David Young
·
#1587
·
|
Re: pseudo
Charles?
Ok noted the black (back) small print??in the software
Either not paying enough attention or being absent minded.Probably both.
It appears??only when no box is crossed .
This will
By
taray singh
·
#1586
·
|
Re: pseudo
Here is my interpretation with most of the peaks labelled. One image shows
how to label the SrKb and ZrKa1 peaks to see both.
[email protected]> wrote:
By
Charles David Young
·
#1584
·
|
Re: pseudo
Charles?
Ok
When 2??major peaks are closeby,they overlap and not possible to identify elements.
Under such circumstances,I have to some??do some manipulation??of peaks??so that both can
By
taray singh
·
#1583
·
|
Re: pseudo
Taray
Just a suggestion. It would be clearer to use large labels for Ka1 and
smaller labels for the rest. Also, always show the Ka1 peak as well as Ka2
and Kb1. This helps verify the ID of the
By
Charles David Young
·
#1582
·
|
Re: pseudo
Here is another glass.
Going from black to white (colorless)
X-ray goggles.
I use??this when??I have to sit next to x-rays wearing only aprons in OT.
My??own personal collection .
So as
By
taray singh
·
#1581
·
|
Re: pseudo
text to follow...
By
taray singh
·
#1580
·
|
Re: pseudo
Here is the pic of the iron welding glass.
Does not come with any welding glass?? grading system.
Very dark .
Repeated xrf
Neodynium detected
By
taray singh
·
#1579
·
|
Re: pseudo
The welding glass is very strong in Ba, Sr and Zr and the Sb must also have some function.
Dud
Sent: Wednesday, December 4, 2024 7:15 AM
To: [email protected]
Subject: Re: [XRF-Page-2] pseudo
By
Dude
·
#1578
·
|
Re: pseudo
My system has undergone some changes recently .
Instead of a close compartment shielding,it is now more open with graded shielding done strategically.
Radiation safety checks done with radiation
By
taray singh
·
#1577
·
|
Re: pseudo
text to follow .
By
taray singh
·
#1576
·
|
Re: pseudo
The uv Abs should be around 250nm
Dud
Sent: Sunday, December 1, 2024 10:00 AM
To: [email protected]
Subject: Re: [XRF-Page-2] pseudo
Dude
Actually quite keen to see reflectance of the 1050 nm
By
Dude
·
#1575
·
|