Re: clock calibrator


 

While the scope response will start falling off at 6 MHz, most scopes will have a usable response at 10 MHz, just not accurate for voltage measurements If the trigger circuit doesn't work at 10 MHz, X-Y mode, if available, should.

John

On 9/11/2022 8:39 AM, Jeff Green wrote:
That of course suggests you have an oscilloscope with a bandwidth of 10MHz.
I've been given a Hitachi oscilloscope designed for ntsc analog that has a maximum frequency response of 6ish MHz.
I've got a line on a Tracor 527E that should do the job.