Keyboard Shortcuts
Likes
- TekScopes
- Messages
Search
Manual for PG508?
Resent due to a mailer error.
* BEGIN FORWARDED MESSAGE * On 22-Jan-12 at 17:46 Bruce Lane <kyrrin@...> wrote: Fellow Tekkies,Bruce Lane, Owner & Head Hardware Heavy, Blue Feather Technologies -- kyrrin (at) bluefeathertech do/t c=o=m "Quid Malmborg in Plano..." |
Re: Tekscopes at the Computer History Museum
These dates sound correct: I remember reading the introductory data sheet
toggle quoted message
Show quoted text
for the 4004 in 1971 or 1972. It made no sense at all. I couldn't figure out what it was. I was used to logic gates and this was alien to me. 1974 sounds right for the 8080. I missed the introduction of that chip but I was building a Z80 system 3 years later. Dennis -----Original Message-----
From: Brad Thompson, Sunday, January 22, 2012 5:34 PM Hello, Tom and the group-- IIRC, the 8080 was introduced in 1974; the 4004 was introduced in 1971. In the early 1960s, I worked as a co-op student at a company that manufactured magnetic-core logic (nonvolatile, radiation-resistant, very low power consumption). Four bits per cubic inch. 73-- Brad AA1IP |
Tektronix 2712/2710/27XX 300Hz Filter F.S.
¿ªÔÆÌåÓýHello All: ? I currently have a Tektronix 300Hz filter for the 27XX series Spectrum Analyzer's for sale. If interested please contact me off the reflector. ? 73
|
Re: 7603 no trace
David,
More for you below. Hope it helps: I think you measured the "high" side of R860(the 130V supply line). Maybe I should have said measure the collector of Q860; this is the same as the base of Q869 and the low side of R860; or should be if connections are OK. Again, this would be with one end of C866 lifted.+69V with ref to ground. Thanks. First, did you see my earlier posting about measuring ripple with an old analog meter that has an "OUTPUT" terminal? Anyway... Here's how I would check for excessive ripple using another (test) scope. This will work for all of the big filter caps that have one terminal connected to chassis ground. DO NOT use this method for the filter cap (C806) in the 130V supply because neither one of its terminals is connected to chassis ground: <<<<<<Be carefully around the AC input/mains power!!!>>>> 1. Ground a 10X probe hooked to the test scope to chassis of problem scope. Use a good-quality clip lead to extend the probe's ground lead if the length of the ground lead is not enough for easy measurements, AND INSULATE the 2 alligators' connection with some black electrical tape so this won't short something out if it accidentally touches anything. 2. Set test scope channel to 50V/div. (Use 5V/div if you've got a scope that does not auto-sense probe attenuation). Be sure to use a 10X probe. 3. Set test scope channel to AC coupling and vertically center the sweep. (You can initially use DC coupling if you want to see the DC component also.) 4. Set test scope for Line trigger, and about 10mS/div. Adjust trigger for a steady sweep (flat line when probe tip is not connected to anything). 5. Carefully probe the "hot" side of each big filter cap. For most, the "hot" side is the "+" terminal. However, for some like C808 (1800 uF) for the -50V supply, it would be the "-" terminal. If the cap is good, you should see a sweep that's still nearly flat. I'm thinking no peak-to-peak waveform on a filter cap should be more than about 3V. If necessary, increase vertical sensitivity to 5V/div, or less, so V peak-to-peak can be more accurately measured. You DON'T won't to overdrive the test scope's channel amp by using too much sensitivity (As a general rule, don't let the waveform go vertically too much off the top/bottom of the screen.) It is good to return the test scope's channel to the 50V/div before going on to the next cap!!!!! To check filter cap C806 in the 130V supply use two 10X probes, two scope channels of the test scope, set one channel for "Invert" and use the "Add" vertical function. Make sure both channels have equal V/div settings, and they are adjusted for equal gain. This is basically a differential measurement. To verify test scope's settings (equal gains, etc.), probe a common signal point with both probes and make sure there's no (or very little) signal/ripple. It will be good to post your ripple measurements. Regards, Jimmy |
Re: Power supply problem with Tek 2220
Tan Chor Ming
¿ªÔÆÌåÓýHi Francis, You are spot on. ?There is no stupid question. ? After I downloaded the 2230 (as directed by Tom) and compared with the 2220/2230. Immediately, I notice the difference.? The 2220/2230 has a thermal shutdown board which is not present in the 2235. So, for my 2220 it is an indication that the thermal shutdown is working.? I believe it is at working at the correct temperature because shutdown always happen when the chassis is burning hot (can hold for a 4 to 5 sec before it burns) I will try to do a test to disconnect the shutdown and see it the shutdown happens again, just to locate the cause. ? Comparison between 2220 and 2235 PS ???????????????????????????? ??2220??????????????????????? 2235????????????????? Comments -5V supply ??????????????Yes???????????? ????????????No R907????????????????????? ??549 ohm????????????????? 357 ohm??? ????????Current rating on +43V for 2220 is about 30% higher Thermal shutdown?? ??Yes??????????????????????? No? ? Rgds, Chor Ming From: TekScopes@... [mailto:TekScopes@...] On Behalf Of Francis
Sent: Monday, January 23, 2012 4:41 AM To: TekScopes@... Subject: [TekScopes] Re: Power supply problem with Tek 2220 ? ? Hi, |
Re: Tekscopes at the Computer History Museum
Brad Thompson
On 1/22/2012 8:29 PM, Thomas Miller wrote:
I worked at Bendix Communications Division from '66 to '71. Even had myHello, Tom and the group-- IIRC, the 8080 was introduced in 1974; the 4004 was introduced in 1971. In the early 1960s, I worked as a co-op student at a company that manufactured magnetic-core logic (nonvolatile, radiation-resistant, very low power consumption). Four bits per cubic inch. 73-- Brad AA1IP |
Re: Tekscopes at the Computer History Museum
¿ªÔÆÌåÓýI worked at Bendix Communications Division from '66 to '71. Even had my own
545 Tek scope. They were the days. DTL had just arrived and a lot of military
systems were just being converted to the pure digital domain. It was around 1971
that the 8080 came out and the world was about to really change.
?
Regards.
Tom
?
|
Re: Tek 7k plug-in prices rising...
G. K.
China has finally re-valued its currency! From: Aaron
To: TekScopes@... Sent: Sunday, January 22, 2012 4:44 PM Subject: [TekScopes] Re: Tek 7k plug-in prices rising...
?
> > Have you seen the BIN price for this?
> > Item 270788500453 > Perhaps that's in HK $ ?? They just forgot to put the decimal point in when typing the price. If you check the sales history, they sold one unit for almost exactly 1/100 of the price in that listing. I wonder what the listing fee was for that ad... Aaron |
Re: Tekscopes at the Computer History Museum
I defer to your superior knowledge of the history of computers, Steve, but I think you contradicted yourself. During the Civil war the new battefield howitzers didn't have the help of digital computers to aim them. What was learned and the mathematics developed for ever more complex artillery aiming schemes, as an example, laid the groundwork for which digital technology later took over and refined the job. Sir Isacc Newton didn't have an Apple ;-)
toggle quoted message
Show quoted text
Arden While analog computers made some amazing advances for their day, I disagree with the comment that they laid the groundwork for modern digital computers. The early designs of digital computers did not leverage anything from analog computers, and took totally independent paths. Probably the only connection is that one of the early digital computers ¨C ENIAC, was designed for the purpose of computing trajectory tables for large field artillery ¨C a similar task the Nike flight path computer performed. The latter provided correction information in real time, while ENIAC actually computed tables of numbers that were published in field manuals. |
Re: Need Manual for Type W, SN 4560 & 5336
Bernd and Egge,
toggle quoted message
Show quoted text
I was aware of the change from Nuvistors to FETs in the 1A1, but didn't know a similar thing had happened to the Type W. If you are able to find the mod kit, would you mind scanning the modified schematic? I'm a complete beginner to electronics and chase enough dead ends even when I have a full manual in front of me. With incomplete schematics I find myself second-guessing everything. :-( I checked eBay and Dave's(ArtekMedia) site but didn't see any manuals for SN >7000, although I sent an inquiry to the eBay listings that didn't show a part number or SN range for the manual. What does PWB stand for, as mentioned in Egge's post below this? Aaron --- In TekScopes@..., "Egge Siert" <eggeja@...> wrote:
It seems that you have two Type W's with the FET-Frontend and the PWB for these. With SN 7000 and above this was standard. For this late versions a new Manual was printed. FET-Frontends (less drift) were used in late Type 1A1's (I don't for sure also 1A2's) and the 1A7A (which has the same circuit as the later 7A22). |
Re: Total beginner with newly acquired 475 with issues
Hi "newbarrie"'
toggle quoted message
Show quoted text
There is far more expertise on this forum than mine but here are some points to get started with, but not specific to the 475: Scopes (and all electronics) that have been sitting around unused for a long time develop not only visible "verdigris" but invisible oxidation and corrosion effects. Wherever two metals are mechanically opposed to pass an electric current is where you will find problems. Apply an electrical contact cleaner that contains a lubricating protectant (I recommend MG Chemicals Super Contact Cleaner) to all connectors, unseat and reseat them at least a couple of times. Plug-in intgrated circuits can also be a problem but leave them to a later level of diagnostics. With switches be a little more careful where you apply the contact cleaner, keep it only to the contacts as well as you can. You can apply cleaner with an artist's brush in tight spaces. Rotate switches several times to restore functioning. Check for loose hardware, tight screws and nuts are required at some points to insure good grounding. You may be surprised at the results you get by performing this procedure. Next, before attempting to do further diagnositics, get a service manual and make it a reading project until you have a good sense of what the scope is all about electronically and how to perform diagnostics and calibration. When you are ready to dig into the cause of particular failures here's the place to get help. Arden ......I also have acquired through the ubiquitous Ebay a half dead Tek 475 scope to play with. ...... |
Re: Force DSA-602 to proceed past 11A34-induced POST error?
It looks like David and Javier were right and this plugin was just missing some sort of calibration constant, fixed by running EA on a good DSA 602 mainframe.
toggle quoted message
Show quoted text
I have now been using it for one week, in various 11k mainframes, with no trouble at all. Thanks again guys! Aaron --- In TekScopes@..., David <davidwhess@...> wrote:
|
Re: Tek 7k plug-in prices rising... 7L13/7L14
If the only thing wrong with the 7L13 is a broken knob, then I think $1k
toggle quoted message
Show quoted text
is a reasonable price. Microwave spectrum analyzers are always expensive. Though a 7L13 or 7L14 is on the low-end of the frequency range, it might be OK for many people, without the $3k . . $5k . . . expense of getting something with a higher frequency range. One potential advantage of the 7L13/14 is that the schematics are available and there is no power supply or display electronics to worry about. I think more modern or similar vintage but more capable spectrum analyzers which are not 7000 series plugins would have a lot more electronics to go wrong, including power supplies, firmware-based microprocessor stuff, CRT displays etc. I recently bought a 7L14, in the 2.5GHz version (without a 1.8GHz LPF and input limiter) for $650 or so. I knew it had problems, and I fixed some of them - multiple dead tantalum capacitors. I now suspect its input mixer needs its diodes replacing, since its sensitivity was very low, and there needs to be quite a lot of work to make the displayed frequency match what the device was actually responding to. At present it is not responding to any signal. Now I know more about these devices, I realize I need the 1.8GHz LPF, but fortunately MiniCircuits make one which should work OK - and the cost is under $50. I have now acquired three of John Griessen's <john@...> excellent 7000 series extender kits: so I will be able to work on this beast. Its not for everyone, but I liken this introduction to microwave electronics to buying my first vehicle - a clapped out 1961 VW Kombi van - and the years of learning experiences as I rebuilt various engines, always imperfectly, and successfully refurbished the gearbox and many other parts. It can't be ruled out that I am crazy too, but I only bid this because someone else was ready to bid a little lower. One fellow in Western Australia has a 7L14 (1.8GHz version) with the TR502 tracking generator - bought on the understanding it was fully working for ~$1.5k. That seems reasonable to me, but it turns out that it is lacking sensitivity and so probably in need of diode replacement in the input mixer, plus potentially other faults. - Robin Magnus wrote: The winning bid for this one leaves me stunning. It comes with no |
Re: Tek 7k plug-in prices rising...
Have you seen the BIN price for this? Perhaps that's in HK $ ??They just forgot to put the decimal point in when typing the price. If you check the sales history, they sold one unit for almost exactly 1/100 of the price in that listing. I wonder what the listing fee was for that ad... Aaron |
Re: Tekscopes at the Computer History Museum
In 1967 I worked at Bendix Aerospace and saw this F4 autopilot on the floor
toggle quoted message
Show quoted text
of one of the factories. I believe Bendix designed it. It is indeed an electromechanical monster. I always wondered how they figured it out it. It must have been a nightmare with all those layers of rods, gears, actuators, and servos. All the autopilots I worked on at Bendix were analog computers. Fortunately when I started there all the new designs use the new uA709 IC OpAmps. That was a revolutionary leap in technology. But before I could fully appreciate the beauty of OpAmps everything changed again. 2 years later autopilots were being designed with digital logic. The Concorde autopilot used DTL. Then they started building B52 subsystems with ROM lookup tables. I used to have to blow out diodes in those tiny ROM packages one bit at a time. They were exciting times to be in electronics. Dennis -----Original Message-----
From: phorphile, Sunday, January 22, 2012 9:22 AM In the Navy in '65 I was treated to a visit inside an F4 Phantom simulator trailor. That was one big analog electromechanical maise on wheels. Analog computers laid the ground work for digital to take off from. ......They have heard of analog computers, sort of, but they're treatedlike the redheaded stepchild. ....... |
Re: Tek 7k plug-in prices rising...
Richard Solomon
Perhaps that's in HK $ ??
toggle quoted message
Show quoted text
73, Dick, W1KSZ On Sun, Jan 22, 2012 at 5:05 PM, J. L. Trantham <jltran@...> wrote:
|
Re: Tek 7k plug-in prices rising...
¿ªÔÆÌåÓýHave you seen the BIN price for this? ? Item? 270788500453 ? Joe ? -----Original Message-----
From: TekScopes@... [mailto:TekScopes@...] On Behalf Of HP Sent: Sunday, January 22, 2012 5:51 PM To: TekScopes@... Subject: [TekScopes] Re: Tek 7k plug-in prices rising... ? ?
|
Re: Tek 7k plug-in prices rising...
Magnus, don't worry, maybe the prices in the past was to low ???
just found: 7L14 Spectrum Analyzer: ONLY $1,499! (SOLD!) from a US used electronic seller So, they expect more, keep your eyes open ;-) Peter ==============================0 Hello,Magnus |
Tek 7k plug-in prices rising...
Hello,
The winning bid for this one leaves me stunning. It comes with no warranty and has a broken knob as per the item description... ?I have no disbelief in the 7L13 spectrum analyser's quality and capabilities. And I am aware that these are offered rarely - but... The buyer was willing to pay 1 grand USD as you US chaps might put it. See ? Cheers, Magnus |