Hi Wamor,
Some years ago i started to fill a table with model's IDs. Maybe, is your
case: the Processor board ID does not correspond to Acq configuration.
See U3, U4 on Proc. board.
This two are on:
00E0 0000 Register (read only) ID Register 1
00E0 0001 Register (read only) ID Register 2
Try this ID and send your to me, please:
TDS640A 1 1 0 0 1 0 1 0
Regards,
Peter
Contact me offboard, if you need a part of schematics from TDS520 regarding
this registers, because this board does not allow attachments
чт, 20 мар. 2025?г. в 14:51, wamor2006 via groups.io <tektronix=
[email protected]>:
toggle quoted message
Show quoted text
Hello everybody,
I managed to upgrade my TDS620 to a TDS640 by changing resistors on the
acquisition-board.
I now have 4 channels active and this is working fine and the scope
reports that it is a TDS640.
The only thing which is bothering me is a message added in the error-log
every time when I start the scope.
Error: 242 wrong hardware configuration
Acq number of digitizer probe, expect: 2, actual 4
This is not limiting the functionality but is just annoying.
Does somebody have some advise how to get rid of this message?
Regards,
Wamor