开云体育

ctrl + shift + ? for shortcuts
© 2025 开云体育

Re: 503 HV Transformer


 

Albert,

Again it's not T601, the LV transformer or any of the voltages from that, that is the problem.
None of those voltages drop out.

ChuckA

On 5/3/2024 6:08 AM, Albert Otten wrote:
Chuck,

I had the same fault as in Joel his 515A in one of my 502As.
It seems you checked filament voltages delivered by T601 and concluded that these were good. But the CRT winding fault is not a short in the winding itself. The problem is that the winding leaks to ground (or whatever) and heavily loads the CRT cathode circuit. When easy to reach a check would be to disconnect both CRT heater leads from the transformer.

Albert




--
See Early TV at:

www.myvintagetv.com

Join [email protected] to automatically receive all group messages.