Many thanks for this version Hans,
?
Unfortunately, this time one of my BS170s blew during the calibration cycle of my QMX+. I used the R command to do the batch. Only one blew, but unfortunately I didn't think to do the fingertip temperature test before clipping them out one by one and checking the current draw after each one. I thought of doing it when there were two left, so it saved me from replacing one of the BS170s as only one was hot!
?
Does anyone have a handle on why calibration seems to injure the PAs? I can't imagine that it generates more thermal stress than an afternoon of digital mode operation. Little voltage stress too as the SWR is low while calibrating into a dummy load. Why should only one go short? Tolerances in breakdown voltage?
?
I found a little bug. It's great to have access to the diagnostic screen from the front panel; I used it to test my replaced PA. Unfortunately, each time you change the band up in frequency, the audio volume increases! The volume control seems to retain its AF gain function while being used to change band.
?
Please keep up the good work! I'm having great fun watching my QMX+ develop and I'm looking forward to using it when I go to Cyprus in a couple of weeks.
?
73 and gratitude,
?
Ellis