On Thu, Oct 31, 2024 at 09:15 AM, Heinz wrote:
The meter dropped around 35.54%
?
I still don't fully understand what this means for the voltage measurements of the NT1-a circuit. Do I need to add about 35% to each voltage measurement to get the correct voltage values?
?
?
Using Henry's procedures, you've been able to establish that the impedance of your meter is around 1M, not 10M as I had originally suggested as a possibility
?
The 35% reduction in voltage measured at that point confirms that the correct polarisation voltage is being applied to the capsule.
As Abbey suggests, time to look elsewhere.
?
Significant reduction in measured meter readings will only occur at very high impedance points.... like the capsule end of a 4M7 resistor!?
Measuring voltages at the various points suggested by Abbey should all return readings pretty much as indicated ( those points are all at a lower impedance )?
?