Keyboard Shortcuts
ctrl + shift + ? :
Show all keyboard shortcuts
ctrl + g :
Navigate to a group
ctrl + shift + f :
Find
ctrl + / :
Quick actions
esc to dismiss
Likes
- HP-Agilent-Keysight-Equipment
- Messages
Search
Upcoming Scrounge, Southern Cal.
This is being posted to: TekScopes, HP, TestGear, and CCTech lists.
Fellow techies, I'm going to have a day or so of opportunity to do some serious scrounging in the southern California region, specifically around Anaheim and vicinity, coming up in May of this year. Being that I haven't been near the area since 1993, I could really use some pointers on who's who in the electronic surplus arena that would be worth a look. My primary interests are in test gear (usually RF and telecommunications, but I keep an open mind), specialized hand tools for connector crimping (both mil-spec and commercial), and "legacy" telephone equipment from the Bell System/Western Electric heyday. So... Let the suggestions fly! ;-) Thanks much. -=-=-=-=-=-=-=-=-=-=-=- Bruce Lane, Owner & Head Hardware Heavy, Blue Feather Technologies -- kyrrin (at) bluefeathertech do/t c=o=m "If Salvador Dali had owned a computer, would it have been equipped with surreal ports?" |
Re: 54110d
Thanks James,
I was hopping to find someone that may have run into a similar problem. I hate paying for service manuals that don't include data for the most important element of any equipment The POWER SUPPLY or photos that are unreadable. My grand kids could have done better with crayons. Back in the days when Motorola came out with the Quasar, (a modular system ) they still provided schematics for troubleshooting. A technician could continue to learn and be more than a module changer. Sorry, enough Venting. Do you know if the schematic and photos are any better on the $25.00 manual you mentioned. T.O. |
usb_gpib Adapters
Paul_group
Hello
I wonder if anyone has had success using Intuilink / Excel with a none HP usb_gpib adapter. I have comms with my instruments using the test application that came with the lead but now need to be a bit more adventurous. I'd be grateful for pointers from anyone who has been down this track before. TIA Regards Paul -- 73 de Paul GW8IZR IO73TI |
Re: 54110d
Pat,
toggle quoted message
Show quoted text
A good place to start is the agilent website. They have made available 100s of manuals for obsolete equipment. The 54110D manual is available at: This service manual does not contain schematic, but it does contain some detailed troubleshooting information. The schematics are available from: www.artekmedia.com You need to get: 54110D $25.00 (3 Vol. Set, Oper., Pgmr., FRU service, Ext Service) Even with this there may not be any schematics for the monitor assembly. I have a 54111D and I believe that the monitor assembly was purchased as a component. I hope that this helps. Regards, John Barnes VE3XRY ---------- Original Message ----------------------------------
From: "tloleksy" <tloleksy@...> Reply-To: hp_agilent_equipment@... Date: Sat, 06 Jan 2007 05:18:48 -0000 I'm in need of help with my HP Agilent 54110D 1GHz scope ¡ No Video ________________________________________________________________ Sent via the WebMail system at aztec-net.com |
Re: HP8620C / HP8621B
Geoff Blake schrieb:
Hi Geoff, I have a 8621B plugin that does not work. So I'd like to find that manual. Not urgent - but would be nice to have. Also have plugin without manuals: **HP86220A 10 - 1300 MHz HP86241A 3,2 - 6,5 GHz** and these modules for the 8621: **HP86320A 0,1 - 2 GHz HP86330A 1,8 - 4.2 GHz HP86331A 1,7 - 4,3 GHz HP86342A 5,9 - 9,0 GHz HP86350A 8 - 12,4 GHz If you could find anything it would be very nice. vy 73, Rainer ** -- VHF/UHF/SHF Online Toplist: DF6NA Homepage: Amateurfunk-Flohmarkt: VHF-DX.net: |
Re: INPUT RC NORMALIZER
you can measure scope input capacitance using a capacitance meter or bridge
toggle quoted message
Show quoted text
just remember to take the capacitance of your test leads or coax into account. i normally just measure the capacitance with the test coax disconnected and then with it hooked up the 1m ohm resistor shouldnt change the reading significantly. thats what the 130 lc meter was designed for . ive seen them used as general purpose measuring devices too. as you know the compensator will act as a 2x attenuator when driven from a low impedance source. you should terminate the pulse generator before the coax enters the compensator "i think" ----- Original Message -----
From: Geoff Blake To: hp group Cc: tekscope group Sent: Friday, January 05, 2007 11:24 AM Subject: Re: [hp_agilent_equipment] INPUT RC NORMALIZER On Fri, 5 Jan 2007, Geoff Blake wrote: > The input normaliser is a series 1M ohm / 47pF capacitor placed in > series with the scope input. It should be as close to the input as > possible. There should be no coax between the input and the > compensator. The 47pF is normally something like a 39pF plus a > trimmer capacitor to set exactly to 47pF. The Tektronix devices > use a chassis mounted male BNC with the C/R soldered to the pin. > > It acts as a potential divider and the input capacitance of the > scope is adjusted on an input squarewave, just like compensating a > scope probe. CORRECTION The series element comprises a 1.0 Mohm and 47pF in parallel, not as I wrote. I wrote that at work and was interrupted by about a dozen telephone queries as I wrote. It is thus: 47pF |-----||-----| generator o---| |---o to scope o----|---|--> |---/\/\/\---| | \ input 1M | / circuit = \ of | / 'scope | \ o--------------------o o----|---|--> Sorry for the error. Geoff -- Geoff Blake G8GNZ located near Chelmsford, Essex, U.K. Please reply to: geoff (at) palaemon (dot) co (dot) uk Using Linux on Intel & Linux or NetBSD on Sun Sparc platforms Please avoid sending me Word or PowerPoint attachments. See <> ---------------------------------------------------------- This E-mail and any attachment(s) are strictly confidential and is intended solely for the addressee(s). If you are not the intended recipient please notify <postmaster(at)palaemon.co.uk> and the sender by return and permanently delete the message. You may not disclose, forward or copy this E-mail or any of its attachments to any third party without the prior consent of the sender. ---------------------------------------------------------- |
Re: RC Normalizers
maybe you can find some cheap chinese 10x probes that wili compensate to a 50 pf input
toggle quoted message
Show quoted text
maybe deane kidd has some older tek probes that have that much range you might be able to build a simple 10 x probe that would be good up to 5 or 10 mhz "heathkit sold probe kits for their early scopes like that" ----- Original Message -----
From: Jerry Massengale To: hp group ; tekscope group Sent: Friday, January 05, 2007 11:21 AM Subject: [hp_agilent_equipment] RC Normalizers Greetings, My thanks to all for the very instructive replies. At the moment SC501's are my immediate concern. I wonder if it might be reasonable to just use 47pf mica cap as the SC501 adjustment instructions call for 47pf with 1 megohm. Surface mount parts would be neat. I will build another with the trimmer for my other scopes. I have some Le Croy 9400's that have such a high input capacity(50pf) that none of my newer probes work with them. Newer probes like the lecroy PP001 and PP002 cause a display with severe leading edge roll-off. Jerry |
54110d
I'm in need of help with my HP Agilent 54110D 1GHz scope ¡ No Video
but can see a brief flash as High Voltage enters CRT and when turning off. LED on first power supply board is lit but no other voltages present on any other test points. Have no service manual ¡.any help would be greatly appreciated. Thanks Pat |
Re: 8620a / 86220a manuals
you have a spare 8620a manual to sell me?
toggle quoted message
Show quoted text
----- Original Message -----
From: Rainer To: hp_agilent_equipment@... Sent: Friday, January 05, 2007 7:09 AM Subject: Re: [hp_agilent_equipment] 8620a / 86220a manuals I have the 8620a manual - looking for 86220a and HP8621B, HP86320A, HP86330A, HP86331A, HP86342A, HP86350A ! Rainer arthurok_2000 schrieb: > > does anyone have these manuals availible > > |
Re: LOGSA AND IE-7 ???
J Forster
Traitors.
Thats what gets my goat, companies or individuals that sabotage, they should be treated as commercial and environment traitors and they should face prospect of jail ! This is not a new thing. In the 1970s, Data General introduced a Nova 2 mini with a potted power fail module that PURPOSELY caused randommemory failures if you did not use DG memory, then spread rumors that second It got quite a bit of notice. See, for example: -John |
Re: HP8620C / HP8621B
Geoff Blake
On Thu, 4 Jan 2007, Geoff Blake wrote:
On Thu, 4 Jan 2007, Rainer wrote:Rainer,Hi,Hi Rainer, Sorry, I was mistaken, I thought I had the .pdf's you need, but they were for single band plug-in's, like the 86245A. If you are really stuck, I probably have paper copies. 73 Geoff -- Geoff Blake G8GNZ located near Chelmsford, Essex, U.K. Please reply to: geoff (at) palaemon (dot) co (dot) uk Using Linux on Intel & Linux or NetBSD on Sun Sparc platforms Please avoid sending me Word or PowerPoint attachments. See <> ------------------------------------------------------------------------------ This E-mail and any attachment(s) are strictly confidential and is intended solely for the addressee(s). If you are not the intended recipient please notify <postmaster(at)palaemon.co.uk> and the sender by return and permanently delete the message. You may not disclose, forward or copy this E-mail or any of its attachments to any third party without the prior consent of the sender. ------------------------------------------------------------------------------ |
Re: LOGSA AND IE-7 ???
Traitors.
toggle quoted message
Show quoted text
Thats what gets my goat, companies or individuals that sabotage, they should be treated as commercial and environment traitors and they should face prospect of jail ! At 03:11 AM 6/01/07, you wrote:
Geoff Blake wrote: |
Re: RC Normalizers
J Forster
I am certain that a 47pF Silver Mica capacitor would do, I think
that the effort of making a surface mount version would be overkill, just string the components across a BNC male/female pair in a small screened box and that will do. These boxes were available in a wide range of capacitances and were used to 'standardize' the input capacitance to enable probes to be switched between 'scopes (of the same input capacitance). Geoff Tek just uses an off the shelf ITT Pomona cast box, roughly 1" x 1" x 2", with M and F chassis mount BNCs on the ends and wired the R & C from center conductor to center conductor. Trivial. -John |
Re: LOGSA AND IE-7 ???
J Forster
Geoff Blake wrote:
[snip] I find it strange that any successful non-microsoft product, like Opera, Word Perfect, Samba, etc. is strangely broken by an 'improvement' to Windows.... Geoff This is not a new thing. In the 1970s, Data General introduced a Nova 2 mini with a potted power fail module that PURPOSELY caused random memory failures if you did not use DG memory, then spread rumors that second source memory was no good. I eventually unpotted one of the modules. They CLEARLY engineered it in. There was no other POSSIBLE use for the circuit. -John |
Re: RC Normalizers
Geoff Blake
On Fri, 5 Jan 2007, Jerry Massengale wrote:
Greetings,I am sure that you will have seen Craigs post (and mine) pointing out my error. I am certain that a 47pF Silver Mica capacitor would do, I think that the effort of making a surface mount version would be overkill, just string the components across a BNC male/female pair in a small screened box and that will do. These boxes were available in a wide range of capacitances and were used to 'standardize' the input capacitance to enable probes to be switched between 'scopes (of the same input capacitance). Geoff -- Geoff Blake G8GNZ located near Chelmsford, Essex, U.K. Please reply to: geoff (at) palaemon (dot) co (dot) uk Using Linux on Intel & Linux or NetBSD on Sun Sparc platforms Please avoid sending me Word or PowerPoint attachments. See <> ------------------------------------------------------------------------------ This E-mail and any attachment(s) are strictly confidential and is intended solely for the addressee(s). If you are not the intended recipient please notify <postmaster(at)palaemon.co.uk> and the sender by return and permanently delete the message. You may not disclose, forward or copy this E-mail or any of its attachments to any third party without the prior consent of the sender. ------------------------------------------------------------------------------ |
Re: LOGSA AND IE-7 ???
The IT people at one of my employers have stated "DO NOT INSTALL IE7 ON ANY COMPANY OWNED EQUIPMENT!" in big red letters on the intranet home page...
toggle quoted message
Show quoted text
-------------- Original message --------------
From: "Matt" <rmc321@...> About 3 months ago, I downloaded the Beta Version of IE7 from the Microsoft site. After encountering compatability problems with some websites, I decided to fall back to the IE6 release. BIG MISTAKE! The uninstall program for the Beta IE7 left my computer in an unbootable condition. I had to go through great pains to get rid of the various IE7-related files on the computer and get everything working as before. Now, I'm a little apprehensive about upgrading to the IE7 Release Version. --- In hp_agilent_equipment@..., "langlv56" <langx@...> wrote: Explorer -7 to work with the LOGSA site |
Re: INPUT RC NORMALIZER
Geoff Blake
On Fri, 5 Jan 2007, Geoff Blake wrote:
The input normaliser is a series 1M ohm / 47pF capacitor placed inCORRECTION The series element comprises a 1.0 Mohm and 47pF in parallel, not as I wrote. I wrote that at work and was interrupted by about a dozen telephone queries as I wrote. It is thus: 47pF |-----||-----| generator o---| |---o to scope o----|---|--> |---/\/\/\---| | \ input 1M | / circuit = \ of | / 'scope | \ o--------------------o o----|---|--> Sorry for the error. Geoff -- Geoff Blake G8GNZ located near Chelmsford, Essex, U.K. Please reply to: geoff (at) palaemon (dot) co (dot) uk Using Linux on Intel & Linux or NetBSD on Sun Sparc platforms Please avoid sending me Word or PowerPoint attachments. See <> ------------------------------------------------------------------------------ This E-mail and any attachment(s) are strictly confidential and is intended solely for the addressee(s). If you are not the intended recipient please notify <postmaster(at)palaemon.co.uk> and the sender by return and permanently delete the message. You may not disclose, forward or copy this E-mail or any of its attachments to any third party without the prior consent of the sender. ------------------------------------------------------------------------------ |
RC Normalizers
Jerry Massengale
Greetings,
My thanks to all for the very instructive replies. At the moment SC501's are my immediate concern. I wonder if it might be reasonable to just use 47pf mica cap as the SC501 adjustment instructions call for 47pf with 1 megohm. Surface mount parts would be neat. I will build another with the trimmer for my other scopes. I have some Le Croy 9400's that have such a high input capacity(50pf) that none of my newer probes work with them. Newer probes like the lecroy PP001 and PP002 cause a display with severe leading edge roll-off. Jerry |
Re: LOGSA AND IE-7 ???
Antonio Falcao
--- In hp_agilent_equipment@..., Geoff Blake <geoff@...>
wrote: Just to go a little bit further, there is also Opera, which IMO,I use Opera since the early versions. It is great! The early versions didn't like some sites with Microsoft-specific content, but the present version can read just about anything. I only open IE on rare cases. The user interface is far superior to IE and once you become accustomed to it, it's hard to go back to IE. I find it interesting that the same version of Opera running onI run Opera on Win98 and it is quite stable. And if anything go wrong and you are forced to exit, on return, a dialog box asks if you want to reload the pages where you were in the first place or a blank one. Nice! I find it strange that any successful non-Microsoft product, likeThis is precisely the notorious Microsoft's interpretation of the word "improvement" ... Regards to all, |