¿ªÔÆÌåÓý

Date

Upcoming Scrounge, Southern Cal.

 

This is being posted to: TekScopes, HP, TestGear, and CCTech lists.

Fellow techies,

I'm going to have a day or so of opportunity to do some serious scrounging in the southern California region, specifically around Anaheim and vicinity, coming up in May of this year.

Being that I haven't been near the area since 1993, I could really use some pointers on who's who in the electronic surplus arena that would be worth a look. My primary interests are in test gear (usually RF and telecommunications, but I keep an open mind), specialized hand tools for connector crimping (both mil-spec and commercial), and "legacy" telephone equipment from the Bell System/Western Electric heyday.

So... Let the suggestions fly! ;-)

Thanks much.


-=-=-=-=-=-=-=-=-=-=-=-
Bruce Lane, Owner & Head Hardware Heavy,
Blue Feather Technologies --
kyrrin (at) bluefeathertech do/t c=o=m
"If Salvador Dali had owned a computer, would it have been equipped with surreal ports?"


Re: 54110d

 

Thanks James,
I was hopping to find someone that may have run into a similar problem.
I hate paying for service manuals that don't include data for the most
important element of any equipment The POWER SUPPLY or photos that are
unreadable. My grand kids could have done better with crayons. Back in
the days when Motorola came out with the Quasar, (a modular system )
they still provided schematics for troubleshooting. A technician could
continue to learn and be more than a module changer. Sorry, enough
Venting. Do you know if the schematic and photos are any better on the
$25.00 manual you mentioned.
T.O.


usb_gpib Adapters

Paul_group
 

Hello

I wonder if anyone has had success using Intuilink / Excel with a none HP usb_gpib adapter.

I have comms with my instruments using the test application that came with the lead but now need to be a bit more adventurous.

I'd be grateful for pointers from anyone who has been down this track before.

TIA

Regards Paul

--
73 de Paul GW8IZR IO73TI


Re: 54110d

 

Pat,

A good place to start is the agilent website. They have made available 100s of manuals for obsolete equipment. The 54110D manual is available at:



This service manual does not contain schematic, but it does contain some detailed troubleshooting information.

The schematics are available from:

www.artekmedia.com

You need to get:

54110D $25.00 (3 Vol. Set, Oper., Pgmr., FRU service, Ext Service)

Even with this there may not be any schematics for the monitor assembly. I have a 54111D and I believe that the monitor assembly was purchased as a component.

I hope that this helps.


Regards,

John Barnes VE3XRY

---------- Original Message ----------------------------------
From: "tloleksy" <tloleksy@...>
Reply-To: hp_agilent_equipment@...
Date: Sat, 06 Jan 2007 05:18:48 -0000

I'm in need of help with my HP Agilent 54110D 1GHz scope ¡­ No Video
but can see a brief flash as High Voltage enters CRT and when turning
off. LED on first power supply board is lit but no other voltages
present on any other test points. Have no service manual ¡­.any help
would be greatly appreciated.

Thanks Pat







________________________________________________________________
Sent via the WebMail system at aztec-net.com


Re: HP8620C / HP8621B

 

Geoff Blake schrieb:

On Thu, 4 Jan 2007, Geoff Blake wrote:

On Thu, 4 Jan 2007, Rainer wrote:

Hi,

can someone help me with Service manuals for HP8620C
and HP8621B in electronic form - preferred PDF ?
Hi Rainer,

I can probably help with the 8621 and some modules in .pdf, but
not until the weekend at the earliest I am afraid. I am in the
process of sorting the computer room/shack and I will have to
search for the CD.
Hi Geoff,

I have a 8621B plugin that does not work. So I'd like to find
that manual. Not urgent - but would be nice to have.
Also have plugin without manuals:

**HP86220A 10 - 1300 MHz
HP86241A 3,2 - 6,5 GHz**

and these modules for the 8621:

**HP86320A 0,1 - 2 GHz
HP86330A 1,8 - 4.2 GHz
HP86331A 1,7 - 4,3 GHz
HP86342A 5,9 - 9,0 GHz
HP86350A 8 - 12,4 GHz

If you could find anything it would be very nice.

vy 73, Rainer
**



--
VHF/UHF/SHF Online Toplist:


DF6NA Homepage:


Amateurfunk-Flohmarkt:


VHF-DX.net:


Re: INPUT RC NORMALIZER

 

you can measure scope input capacitance using a capacitance meter or bridge
just remember to take the capacitance of your test leads or coax into account.
i normally just measure the capacitance with the test coax disconnected and then with it hooked up
the 1m ohm resistor shouldnt change the reading significantly.
thats what the 130 lc meter was designed for .
ive seen them used as general purpose measuring devices too.
as you know the compensator will act as a 2x attenuator when driven from a low impedance source.
you should terminate the pulse generator before the coax enters the compensator "i think"

----- Original Message -----
From: Geoff Blake
To: hp group
Cc: tekscope group
Sent: Friday, January 05, 2007 11:24 AM
Subject: Re: [hp_agilent_equipment] INPUT RC NORMALIZER


On Fri, 5 Jan 2007, Geoff Blake wrote:

> The input normaliser is a series 1M ohm / 47pF capacitor placed in
> series with the scope input. It should be as close to the input as
> possible. There should be no coax between the input and the
> compensator. The 47pF is normally something like a 39pF plus a
> trimmer capacitor to set exactly to 47pF. The Tektronix devices
> use a chassis mounted male BNC with the C/R soldered to the pin.
>
> It acts as a potential divider and the input capacitance of the
> scope is adjusted on an input squarewave, just like compensating a
> scope probe.

CORRECTION The series element comprises a 1.0 Mohm and 47pF in
parallel, not as I wrote. I wrote that at work and was interrupted
by about a dozen telephone queries as I wrote.

It is thus:
47pF
|-----||-----|
generator o---| |---o to scope o----|---|-->
|---/&#92;/&#92;/&#92;---| | &#92; input
1M | / circuit
= &#92; of
| / 'scope
| &#92;
o--------------------o o----|---|-->

Sorry for the error.

Geoff

--
Geoff Blake G8GNZ located near Chelmsford, Essex, U.K.
Please reply to: geoff (at) palaemon (dot) co (dot) uk
Using Linux on Intel & Linux or NetBSD on Sun Sparc platforms

Please avoid sending me Word or PowerPoint attachments.
See <>
----------------------------------------------------------

This E-mail and any attachment(s) are strictly confidential
and is intended solely for the addressee(s). If you are not the
intended recipient please notify <postmaster(at)palaemon.co.uk>
and the sender by return and permanently delete the message.

You may not disclose, forward or copy this E-mail or any of its
attachments to any third party without the prior consent of the
sender.

----------------------------------------------------------


Re: RC Normalizers

 

maybe you can find some cheap chinese 10x probes that wili compensate to a 50 pf input
maybe deane kidd has some older tek probes that have that much range
you might be able to build a simple 10 x probe that would be good up to 5 or 10 mhz
"heathkit sold probe kits for their early scopes like that"

----- Original Message -----
From: Jerry Massengale
To: hp group ; tekscope group
Sent: Friday, January 05, 2007 11:21 AM
Subject: [hp_agilent_equipment] RC Normalizers


Greetings,

My thanks to all for the very instructive replies. At the moment SC501's are my immediate concern. I wonder if it might be reasonable to just use 47pf mica cap as the SC501 adjustment instructions call for 47pf with 1 megohm. Surface mount parts would be neat.

I will build another with the trimmer for my other scopes. I have some Le Croy 9400's that have such a high input capacity(50pf) that none of my newer probes work with them. Newer probes like the lecroy PP001 and PP002 cause a display with severe leading edge roll-off.

Jerry


54110d

 

I'm in need of help with my HP Agilent 54110D 1GHz scope ¡­ No Video
but can see a brief flash as High Voltage enters CRT and when turning
off. LED on first power supply board is lit but no other voltages
present on any other test points. Have no service manual ¡­.any help
would be greatly appreciated.

Thanks Pat


Re: 8620a / 86220a manuals

 

you have a spare 8620a manual to sell me?

----- Original Message -----
From: Rainer
To: hp_agilent_equipment@...
Sent: Friday, January 05, 2007 7:09 AM
Subject: Re: [hp_agilent_equipment] 8620a / 86220a manuals


I have the 8620a manual - looking for 86220a and
HP8621B, HP86320A, HP86330A, HP86331A, HP86342A, HP86350A !

Rainer

arthurok_2000 schrieb:
>
> does anyone have these manuals availible
>
>


Re: LOGSA AND IE-7 ???

J Forster
 

Traitors.

Thats what gets my goat, companies or individuals that sabotage, they
should be
treated as commercial and environment traitors and they should face
prospect of
jail !


This is not a new thing. In the 1970s, Data General introduced a Nova 2
mini with a potted power fail module that PURPOSELY caused random
memory
failures if you did not use DG memory, then spread rumors that second
source memory was no good. I eventually unpotted one of the modules.
They CLEARLY engineered it in. There was no other POSSIBLE use for the
circuit.

-John


It got quite a bit of notice. See, for example:



-John


Re: HP8620C / HP8621B

Geoff Blake
 

On Thu, 4 Jan 2007, Geoff Blake wrote:

On Thu, 4 Jan 2007, Rainer wrote:

Hi,

can someone help me with Service manuals for HP8620C
and HP8621B in electronic form - preferred PDF ?
Hi Rainer,

I can probably help with the 8621 and some modules in .pdf, but
not until the weekend at the earliest I am afraid. I am in the
process of sorting the computer room/shack and I will have to
search for the CD.
Rainer,

Sorry, I was mistaken, I thought I had the .pdf's you need, but
they were for single band plug-in's, like the 86245A.

If you are really stuck, I probably have paper copies.

73

Geoff
--
Geoff Blake G8GNZ located near Chelmsford, Essex, U.K.
Please reply to: geoff (at) palaemon (dot) co (dot) uk
Using Linux on Intel & Linux or NetBSD on Sun Sparc platforms

Please avoid sending me Word or PowerPoint attachments.
See <>
------------------------------------------------------------------------------

This E-mail and any attachment(s) are strictly confidential
and is intended solely for the addressee(s). If you are not the
intended recipient please notify <postmaster(at)palaemon.co.uk>
and the sender by return and permanently delete the message.

You may not disclose, forward or copy this E-mail or any of its
attachments to any third party without the prior consent of the
sender.

------------------------------------------------------------------------------


Re: LOGSA AND IE-7 ???

 

Traitors.

Thats what gets my goat, companies or individuals that sabotage, they should be
treated as commercial and environment traitors and they should face prospect of
jail !

At 03:11 AM 6/01/07, you wrote:

Geoff Blake wrote:

[snip]

I find it strange that any successful non-microsoft product, like
Opera, Word Perfect, Samba, etc. is strangely broken by an
'improvement' to Windows....

Geoff

This is not a new thing. In the 1970s, Data General introduced a Nova 2
mini with a potted power fail module that PURPOSELY caused random memory
failures if you did not use DG memory, then spread rumors that second
source memory was no good. I eventually unpotted one of the modules.
They CLEARLY engineered it in. There was no other POSSIBLE use for the
circuit.

-John


Re: RC Normalizers

J Forster
 

I am certain that a 47pF Silver Mica capacitor would do, I think
that the effort of making a surface mount version would be
overkill, just string the components across a BNC male/female pair
in a small screened box and that will do.

These boxes were available in a wide range of capacitances and
were used to 'standardize' the input capacitance to enable probes
to be switched between 'scopes (of the same input capacitance).

Geoff



Tek just uses an off the shelf ITT Pomona cast box, roughly 1" x 1" x
2", with M and F chassis mount BNCs on the ends and wired the R & C
from center conductor to center conductor. Trivial.

-John


Re: LOGSA AND IE-7 ???

J Forster
 

Geoff Blake wrote:

[snip]

I find it strange that any successful non-microsoft product, like
Opera, Word Perfect, Samba, etc. is strangely broken by an
'improvement' to Windows....

Geoff



This is not a new thing. In the 1970s, Data General introduced a Nova 2
mini with a potted power fail module that PURPOSELY caused random memory
failures if you did not use DG memory, then spread rumors that second
source memory was no good. I eventually unpotted one of the modules.
They CLEARLY engineered it in. There was no other POSSIBLE use for the
circuit.

-John


Re: RC Normalizers

Geoff Blake
 

On Fri, 5 Jan 2007, Jerry Massengale wrote:

Greetings,
My thanks to all for the very instructive replies. At the
moment SC501's are my immediate concern. I wonder if it might
be reasonable to just use 47pf mica cap as the SC501
adjustment instructions call for 47pf with 1 megohm. Surface
mount parts would be neat.

I will build another with the trimmer for my other scopes. I
have some Le Croy 9400's that have such a high input
capacity(50pf) that none of my newer probes work with them.
Newer probes like the lecroy PP001 and PP002 cause a display
with severe leading edge roll-off.
I am sure that you will have seen Craigs post (and mine) pointing
out my error.

I am certain that a 47pF Silver Mica capacitor would do, I think
that the effort of making a surface mount version would be
overkill, just string the components across a BNC male/female pair
in a small screened box and that will do.

These boxes were available in a wide range of capacitances and
were used to 'standardize' the input capacitance to enable probes
to be switched between 'scopes (of the same input capacitance).

Geoff

--
Geoff Blake G8GNZ located near Chelmsford, Essex, U.K.
Please reply to: geoff (at) palaemon (dot) co (dot) uk
Using Linux on Intel & Linux or NetBSD on Sun Sparc platforms

Please avoid sending me Word or PowerPoint attachments.
See <>
------------------------------------------------------------------------------

This E-mail and any attachment(s) are strictly confidential
and is intended solely for the addressee(s). If you are not the
intended recipient please notify <postmaster(at)palaemon.co.uk>
and the sender by return and permanently delete the message.

You may not disclose, forward or copy this E-mail or any of its
attachments to any third party without the prior consent of the
sender.

------------------------------------------------------------------------------


Re: LOGSA AND IE-7 ???

 

The IT people at one of my employers have stated "DO NOT INSTALL IE7 ON ANY COMPANY OWNED EQUIPMENT!" in big red letters on the intranet home page...

-------------- Original message --------------
From: "Matt" <rmc321@...>
About 3 months ago, I downloaded the Beta Version of IE7 from the
Microsoft site. After encountering compatability problems with some
websites, I decided to fall back to the IE6 release. BIG MISTAKE!
The uninstall program for the Beta IE7 left my computer in an
unbootable condition. I had to go through great pains to get rid of
the various IE7-related files on the computer and get everything
working as before. Now, I'm a little apprehensive about upgrading
to the IE7 Release Version.

--- In hp_agilent_equipment@..., "langlv56" <langx@...>
wrote:

I have the same trouble, and simply use Mozilla for LOGSA site.
Lang

--- In hp_agilent_equipment@..., Dave-NR1DX/0 <nr1dx@>
wrote:



Has anyone out there figured out how to get the new Internet
Explorer
-7 to work with the LOGSA site


Dave
NR1DX/0



Re: INPUT RC NORMALIZER

Geoff Blake
 

On Fri, 5 Jan 2007, Geoff Blake wrote:

The input normaliser is a series 1M ohm / 47pF capacitor placed in
series with the scope input. It should be as close to the input as
possible. There should be no coax between the input and the
compensator. The 47pF is normally something like a 39pF plus a
trimmer capacitor to set exactly to 47pF. The Tektronix devices
use a chassis mounted male BNC with the C/R soldered to the pin.

It acts as a potential divider and the input capacitance of the
scope is adjusted on an input squarewave, just like compensating a
scope probe.
CORRECTION The series element comprises a 1.0 Mohm and 47pF in
parallel, not as I wrote. I wrote that at work and was interrupted
by about a dozen telephone queries as I wrote.

It is thus:
47pF
|-----||-----|
generator o---| |---o to scope o----|---|-->
|---/&#92;/&#92;/&#92;---| | &#92; input
1M | / circuit
= &#92; of
| / 'scope
| &#92;
o--------------------o o----|---|-->

Sorry for the error.

Geoff

--
Geoff Blake G8GNZ located near Chelmsford, Essex, U.K.
Please reply to: geoff (at) palaemon (dot) co (dot) uk
Using Linux on Intel & Linux or NetBSD on Sun Sparc platforms

Please avoid sending me Word or PowerPoint attachments.
See <>
------------------------------------------------------------------------------

This E-mail and any attachment(s) are strictly confidential
and is intended solely for the addressee(s). If you are not the
intended recipient please notify <postmaster(at)palaemon.co.uk>
and the sender by return and permanently delete the message.

You may not disclose, forward or copy this E-mail or any of its
attachments to any third party without the prior consent of the
sender.

------------------------------------------------------------------------------


RC Normalizers

Jerry Massengale
 

Greetings,

My thanks to all for the very instructive replies. At the moment SC501's are my immediate concern. I wonder if it might be reasonable to just use 47pf mica cap as the SC501 adjustment instructions call for 47pf with 1 megohm. Surface mount parts would be neat.

I will build another with the trimmer for my other scopes. I have some Le Croy 9400's that have such a high input capacity(50pf) that none of my newer probes work with them. Newer probes like the lecroy PP001 and PP002 cause a display with severe leading edge roll-off.

Jerry


Re: LOGSA AND IE-7 ???

Antonio Falcao
 

--- In hp_agilent_equipment@..., Geoff Blake <geoff@...>
wrote:

Just to go a little bit further, there is also Opera, which IMO,
hase advantages over the others mentioned.
Opera and Firefox also run natively on most UNIXs including Linux.
I use Opera since the early versions. It is great!
The early versions didn't like some sites with Microsoft-specific
content, but the present version can read just about anything. I only
open IE on rare cases. The user interface is far superior to IE and
once you become accustomed to it, it's hard to go back to IE.

I find it interesting that the same version of Opera running on
Linux is vastly more stable than when running under XP. It seems
like that the display engine that Microsoft uses causes Opera to
crash regularly.
I run Opera on Win98 and it is quite stable. And if anything go wrong
and you are forced to exit, on return, a dialog box asks if you want
to reload the pages where you were in the first place or a blank one.
Nice!

I find it strange that any successful non-Microsoft product, like
Opera, Word Perfect, Samba, etc. is strangely broken by an
'improvement' to Windows....
Geoff
This is precisely the notorious Microsoft's interpretation of the
word "improvement" ...

Regards to all,


Re: INPUT RC NORMALIZER

 

The input normaliser is a series 1M ohm / 47pF
No! It is a *parallel* 1M/47pF in *series* with the input.

You knew that of course!

Craig