Keyboard Shortcuts
ctrl + shift + ? :
Show all keyboard shortcuts
ctrl + g :
Navigate to a group
ctrl + shift + f :
Find
ctrl + / :
Quick actions
esc to dismiss
Likes
- HP-Agilent-Keysight-Equipment
- Messages
Search
Re: Introduction
Hi Robert,
toggle quoted message
Show quoted text
I have two HP scopes. One is a 130C, which I will probably keep, at least for now. The other is a 140A with 1405A and 1420A plug ins. I will sell the 140A but at this time I have no idea what condition it is in, either cosmetically or functionally. If you are interested in the 140A let me know and I will check it out and get back to you. I also have an 851B Spectrum Analyzer Display, but I only have the display, not the rest of the unit. I will probably scrap the 851B for parts so if you need any knobs or other scope parts contained in the display unit I might be able to help you. With best wishes, Jack =================================== JD Crone Associates, LLC Computer Forensics - Data Recovery 5534 South Sixth Street #120 Klamath Falls, OR 97603 Voice: 626.441.8441 Fax: 626.441.6425 =================================== Robert Middleton wrote: Hello Jack. |
hp 5100A /5110A synth set
morriso2002
Hi all,
I'm new to this group, but not so new to vintage HP and other test equipment. I'm sure there are a few familar names here! I have recently found a nice clean 5100A/5110A synthesizer set and would like to get it up & running. I tried the 5110A and found two problems: 1. The 1 MHz output is fine but none of the other outputs are there 2. The oven temp meter reading just keeps getting higher & higher till the meter goes off scale...obviously I have not left it in standby mode! Help! I really need some advice and especially a set of manuals. I am located in Melbourne Australia and would be happy to pay for copying & postage costs if anyone can help. Thanks, Morris Odell |
Re: Introduction
Robert Middleton
开云体育?
|
Re: Introduction
Robert Middleton
开云体育Hello Jack.
?
This is Robert.?I have a list of H.P.
Oscilliscopes I am looking for. Perhaps you might have a few of them or perhaps
you could point me in the direction of where I can locate them? Enclosed is my
list and I will keep an eye out for manuals you need. Thanks.
?
Respectfully, Robert
?
p.s. Below is my list of H.P. oscilliscopes;
?
OS-121A/USM-140
OS-82A/USM-105
OS-121C/USM-140
OS-121D/USM-140
?
?
|
Re: Introduction
开云体育I'm in Tulsa, OK..
|
Re: Introduction
toggle quoted message
Show quoted text
|
Introduction
Greetings All,
I am a new member of the group and am looking forward to an enjoyable time here. I have a large inventory of HP boat anchors which I want to dispose of. Some I want to sell as functional units, others might get parted out if there is any market for these parts. There are over 60 units consisting of these models: 130C, 140A, 1900A, 200CD, 214A, 302B, 342A, 400D, 400H, 411A, 415B, 428A, 431B, 5210A, 523C, 606A, 608C, 608D, 612A, 614A, 616A, 618B, 626A, 694A, 851B, 8690A, and probably a few others. Any suggestions for disposing of this would be appreciated. I also need manuals for most models and there are just too many to buy them. I think that there are downloadable manuals for the equivalent military units but I don't know the military model numbers. Is there a cross reference list available? Thanks, Jack |
HP 3310A Function Generator - Problem
David Jarman
I managed to switch off and on my trusty HP 3310A yesterday while it
was connected to an audio system (not good practise!) and it now refuses to generate a signal from the low/high outputs. The mains indicator light comes on and the fuse appears OK. I don't have a circuit diagram. Can anyone help me to get my 3310A operational again please? Thanks in anticipation. David Jarman |
follow-up - HP 3439A
computeruser04
The HP 3439A has been repaired. It was C8 on A9 that had failed.
I then zeroed the readout it using a calibration procedure found at . Thanks to everyone who replied. I also have a service manual on the way to me from Joe VE7LBI. Question - I zero the readout after a 30minute warmup. All ranges read 0000 with the + & - flashing alternately. The Int Check -8000 is also set per the precedure. It will stay like that (zeroed) all day. If I turn it off then back on the next day - the zero calibration is off - not by much - sometimes +0001 or -0002. I can zero it again - and it will stay like that all day. Is this normal or am I being anal about a +35 year old instrument? Thank BL --- In hp_agilent_equipment@..., "computeruser04" <computeruser@s...> wrote: Hello All |
Re: Manual Wanted
开云体育Hello Robin
I have operators book scanned-will You have them
uploaded?
??????????? Best
Regards
?????????????????????????????
Hardy
|
Re: Manual Wanted
Original Message:
Date: Thu, 6 May 2004 21:00:54 +0100 From: Robin Birch <robinb@...> Subject: Manual Wanted Hi, Has anyone got a manual that I can copy, scan or whatever for a HP 1740A? Or point me towards where I can download one? All costs re-imbursed. Regards Robin -- Robin Birch Robin, I have bunches of HP manuals, at: . For the 1740A, it loos like all I have is the operator's guides, not a service manual. I think ONE of the ones that I have might also be downloadable from agilent.com . Good luck! Tom Gootee tomg@... |
Re: HP 3439A
Joseph Orgnero
Sorry, it was a typo, I should have typed 3440. The manual is operating
toggle quoted message
Show quoted text
and service with schematics. My e-mail is: joseph@... Thank you ----- Original Message -----
From: "computeruser04" <computeruser@...> To: <hp_agilent_equipment@...> Sent: 02 May 2004 11:53 AM Subject: [hp_agilent_equipment] Re: HP 3439A JoeSponsor ---------------------~--> Buy Ink Cartridges or Refill Kits for your HP, Epson, Canon or LexmarkCanada. ->
|
Re: HP 3439A
computeruser04
Joe
I am interested in the manual if it is a service manual with a schematic. You say it is the same as the 3449 (typo?) Is it the same as the 3439 except for the sampe rate? If so I am interested. leave me an email or web address Thanks BL --- In hp_agilent_equipment@..., "Joseph Orgnero" <joseph@p...> wrote: Jorgen,same as the 3449 except for the sample rate, cost U$S 12.00 plusshipping. Let me know if interested.with. schematicIt has the 3443 High Gain/Auto Range plugin. The Nixie tubes itsand found nothing. Really, like others have said here before, aboutthe challenge to see if I can get it functioning, so any info it is appreciated.Did you check all supply voltages for ripple? |
Re: HP 3439A
Joseph Orgnero
Jorgen,
toggle quoted message
Show quoted text
I have an original manual for the HP 3440A voltmeter, which is the same as the 3449 except for the sample rate, cost U$S 12.00 plus shipping. Let me know if interested. Thank you. Joe Orgnero VE7LBI ----- Original Message -----
From: "Jorgen Lund-Nielsen" <dj0ud@...> To: <hp_agilent_equipment@...> Sent: 01 May 2004 06:05 PM Subject: [hp_agilent_equipment] Re: HP 3439A --- In hp_agilent_equipment@..., "computeruser04" |
Re: HP 3439A
computeruser04
Ripple is about 1.5v on the 150v supplies and about .5v on the 50v
supply. This site: has the calibration procedure for the 3439A which gave me some more good information. This site: mentions the 3440A which is very similar and their unit has the same symptoms: "The nixie tubes light up, but multiple segments are on simultaneously" so I am thinking this problem is common on these units. Thanks for the replies so far. BL --- In hp_agilent_equipment@..., "Jorgen Lund-Nielsen" <dj0ud@w...> wrote: --- In hp_agilent_equipment@..., "computeruser04"about it is appreciated.Did you check all supply voltages for ripple? |
Re: HP 3439A
--- In hp_agilent_equipment@..., "computeruser04"
<computeruser@s...> wrote: Hello AllDid you check all supply voltages for ripple? Power Supplys has to be checked first, ever! Jorgen |
Re: HP 3439A
开云体育I
don't know if it will make you feel any better but I have a Fairchild Model
7000, 5 1/2 digit Nixie tube?DMM? and I use it all the time.?
Works perfect.? I also have a Systron Donner 6152A, 500 mHz Nixie freq.
counter and it also works perfect.? I love Nixies -no reading glasses
required!? The pinnacle of display technology, IMHO, ?was planar
gas.? LCD displays were the downfall of modern electronics- screw low power
consumption!?
?
Sorry
I can't help you with the schematic.? There are many vintage manual
resellers (and some free) ?out there? try:
?
?
?
?
?
?
?
?
?
?
Good
Luck!
|
HP 3439A
computeruser04
Hello All
I was just given an old HP 3439A Digital Voltmeter to play with. It has the 3443 High Gain/Auto Range plugin. The Nixie tubes light but display random digits. I have searched for a schematic and found nothing. Really, like others have said here before, its the challenge to see if I can get it functioning, so any info about it is appreciated. Thanks BL |
to navigate to use esc to dismiss